Feasibility of cardiac output estimation by ultrasonic cardiac output monitoring in the prehospital setting

被引:14
|
作者
Duchateau, Francois-Xavier [1 ]
Gauss, Tobias [1 ]
Burnod, Alexis [1 ]
Ricard-Hibon, Agnes [1 ]
Juvin, Philippe [1 ]
Mantz, Jean [1 ]
机构
[1] Beaujon Univ Hosp, Dept Anaesthesiol & Intens Care, F-92110 Clichy, France
关键词
cardiac output; prehospital; shock; EMERGENCY PHYSICIANS; USCOM;
D O I
10.1097/MEJ.0b013e32834777b6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The possible benefits of ultrasonic cardiac output monitoring (USCOM) in emergency medicine practice could be significant if evaluated in a goal-directed protocol. The aim of this study was to perform a feasibility study in a physician-staffed prehospital emergency medicine system. This study enrolled a convenient sample of 50 patients with circulatory distress. Main criteria were visualization of acceptable curves and obtaining interpretable values. Acceptable curves and interpretable values (main criterion) were obtained for 35 patients (70%). In case of failure, the patient was very often dyspneic (80 vs. 23%, when the technique was successful, P < 0.001). Mean duration of USCOM examination was 105 +/- 60 s. The acceptable success rate for a new technique we observed and the high easy-to-use score suggests that the use of USCOM is feasible in prehospital emergency medicine. European Journal of Emergency Medicine 18:357-359 (C) 2011 Wolters Kluwer Health | Lippincott Williams & Wilkins.
引用
收藏
页码:357 / 359
页数:3
相关论文
共 50 条
  • [1] Feasibility of transcutaneous cardiac output monitoring using continuous wave Doppler ultrasound: Ultrasonic Cardiac Output Monitor (USCOM)
    Phillips, R
    Dadd, M
    Gill, R
    West, M
    Burstow, D
    [J]. PROCEEDINGS OF THE 5TH WORLD CONGRESS OF ECHOCARDIOGRAPHY AND VASCULAR ULTRASOUND, 2001, : 23 - 30
  • [2] NONINVASIVE ULTRASONIC ESTIMATION OF CHANGES IN CARDIAC-OUTPUT
    COLOCOUSIS, JS
    HUNTSMAN, LL
    CURRERI, PW
    [J]. SURGICAL FORUM, 1977, 28 : 198 - 200
  • [3] Minimally Invasive Cardiac Output Monitoring in the Perioperative Setting
    Funk, Duane J.
    Moretti, Eugene W.
    Gan, Tong J.
    [J]. ANESTHESIA AND ANALGESIA, 2009, 108 (03): : 887 - 897
  • [4] Cardiac output monitoring
    de Waal, Eric. E. C.
    Wappler, Frank
    Buhre, Wolfgang F.
    [J]. CURRENT OPINION IN ANESTHESIOLOGY, 2009, 22 (01) : 71 - 77
  • [5] Monitoring cardiac output
    De Backer, Daniel
    Hajjar, Ludhmila
    Monnet, Xavier
    [J]. INTENSIVE CARE MEDICINE, 2024,
  • [6] Cardiac output monitoring
    Mathews, Lailu
    Singh, Kalyan R. K.
    [J]. ANNALS OF CARDIAC ANAESTHESIA, 2008, 11 (01) : 56 - 68
  • [7] Cardiac output monitoring
    Betteridge, Nathan
    Armstrong, Fiona
    [J]. ANAESTHESIA AND INTENSIVE CARE MEDICINE, 2022, 23 (02): : 101 - 110
  • [8] Cardiac resynchronization therapy optimization by ultrasonic cardiac output monitoring (USCOM) device
    Siu, Chung-Wah
    Tse, Hung-Fat
    Lee, Kathy
    Chan, Hon-Wah
    Chen, Wai-Hong
    Yung, Cindy
    Lee, Stephen
    Lau, Chu-Pak
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (01): : 50 - 55
  • [9] Ultrasonic cardiac output monitor for cardiac output measurement: is it equal to conventional echocardiography?
    Schiffer, P. Meyer
    Daster, C.
    Adams, M.
    Mieth, R. Arlettaz
    [J]. SWISS MEDICAL WEEKLY, 2013, 143 : 21S - 21S
  • [10] In vitro evaluation of an ultrasonic cardiac output monitoring (USCOM) device
    Gregory, Shaun D.
    Cooney, Helena
    Diab, Sara
    Anstey, Chris
    Thom, Ogilvie
    Fraser, John F.
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (01) : 69 - 75