In this study, we investigate the stability of a pipe network for differential pressure (DP) control of a variable flow air-conditioning chilled water system. First, the hydraulic properties of the pipe network and the thermal properties of the terminal air-conditioning equipment are presented, and the thermal stability is defined to serve as an indicator of the impact that flow regulation in the active branches has on the energy supply capacity of the passive branches. An evaluation indicator of the thermal stability is also developed for online applications. Second, dynamic changes in the hydraulic and thermal properties of the passive branches of a primary pump variable flow dual loop air-conditioning water system were experimentally studied during an active branch regulating valve action stroke cycle using an uncontrolled hydraulic pump, constant DP control and variable DP set-point control. The feasibility and energy savings of various DP control strategies were evaluated in terms of the thermal stability and energy savings for hydraulic pumps. The results show that using a variable DP set-point control strategy produced significant energy savings; however, the thermal stability must be considered when setting the step size in adjusting the DP set-point. (C) 2013 Published by Elsevier Ltd.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [31] Performance evaluation of the variable refrigerant flow (VRF) air-conditioning system subjected to partial and unbalanced thermal loadings
    Enteria, Napoleon
    Yamaguchi, Hideki
    Miyata, Masato
    Sawachi, Takao
    Kuwasawa, Yasou
    JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2016, 11 (01):
  • [32] Experimental study of a bilinear control for a GSHP integrated air-conditioning system
    Gao, Jiajia
    Huang, Gongsheng
    Xu, Xinhua
    ENERGY AND BUILDINGS, 2016, 133 : 104 - 110
  • [33] Experimental data for an air-conditioning system identification
    Ramirez, Hermes
    Jimenez-Cabas, Javier
    Bula, Antonio
    DATA IN BRIEF, 2019, 25
  • [34] Modelling and simulation of a variable speed air-conditioning system
    Popescu, M. C.
    Petrisor, A.
    Drighiciu, M. A.
    2008 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS (AQTR 2008), THETA 16TH EDITION, VOL II, PROCEEDINGS, 2008, : 115 - 120
  • [35] Experimental study of model predictive control for an air-conditioning system with dedicated outdoor air system
    Yang, Shiyu
    Wan, Man Pun
    Ng, Bing Feng
    Dubey, Swapnil
    Henze, Gregor P.
    Chen, Wanyu
    Baskaran, Krishnamoorthy
    APPLIED ENERGY, 2020, 257
  • [36] Temperature and humidity control with a model predictive control method in the air-conditioning system
    Liu Jingyun
    Li Ping
    2017 INTERNATIONAL CONFERENCE ON ADVANCED MECHATRONIC SYSTEMS (ICAMECHS), 2017, : 408 - 412
  • [37] Application of water loop variable refrigerant flow air-conditioning system in high rise buildings in North China
    Sun, Ting-Ting
    Ni, Long
    Yao, Yang
    Ma, Zui-Liang
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2009, 36 (SUPPL. 2): : 133 - 136
  • [38] Decoupling Control of a Variable-Air-Volume Air-Conditioning System Based on State Feedback
    Huang, Yonghong
    Yang, Xuejun
    2008 INTERNATIONAL SYMPOSIUM ON INTELLIGENT INFORMATION TECHNOLOGY APPLICATION, VOL III, PROCEEDINGS, 2008, : 589 - +
  • [39] Thermal and hydraulic analysis of compact evaporator for automotive air-conditioning system
    Lee, KH
    Won, JP
    VTMS 4: VEHICLE THERMAL MANAGEMENT SYSTEMS, 1999, : 91 - 104
  • [40] Energy simulation in the variable refrigerant flow air-conditioning system under cooling conditions
    Zhou, Y. P.
    Wu, J. Y.
    Wang, R. Z.
    Shiochi, S.
    ENERGY AND BUILDINGS, 2007, 39 (02) : 212 - 220