Failure analysis of isolation valve stems in steam generator blow down system

被引:5
|
作者
Jung, Yong Chan [1 ]
Lee, Tae Hee [1 ]
Kim, Min Tae [1 ]
机构
[1] Korea Elect Power Res Inst, Taejon 305380, South Korea
关键词
Isolation valve; Stem failure; Full annealing; Mechanical properties;
D O I
10.1016/j.engfailanal.2013.03.006
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Two isolation valves failed prematurely in the steam generator blow down system of a nuclear power plant. Metallurgical analysis of the damaged stems in the isolation valves was made. Heat treatment tests were carried out to verify the reliability of stems in comparison with the required mechanical specifications. The results of the analysis showed the abnormal precipitation of nonmetallic inclusions, MnS, in the matrix. These nonmetallic inclusions which could acts as notches were distributed randomly to 0.2 vol.%, two times higher than those of typical materials. In addition, the hardness of the damaged stems was twofold higher and the elongation was reduced by half compared to those values attainable from a proper full annealing. It is concluded that improper tempering applied to the damaged stems resulted in second hardening and decrease in toughness, consequently shortening the life of the stems. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:98 / 105
页数:8
相关论文
共 50 条
  • [1] Analysis and Solutions of Blocking of Steam Generator Secondary Blow-down Sampling Line
    Meng X.
    Lei S.
    Chen J.
    Hedongli Gongcheng/Nuclear Power Engineering, 2020, 41 : 175 - 178
  • [2] Failure Analysis and Reliability Improvement of Control System of Main Steam Isolation Valve in Nuclear Power Plants
    Li X.
    Hedongli Gongcheng/Nuclear Power Engineering, 2021, 42 (01): : 138 - 142
  • [3] Failure analysis of a steam valve stem
    Ipohorski, M
    Luppo, MI
    Castillo-Guerra, R
    Ovejero-García, J
    MATERIALS CHARACTERIZATION, 2003, 50 (01) : 23 - 30
  • [4] Failure analysis of a dissimilar weld joint in a steam generator
    Joseph, A
    Ramesh, AS
    Jayakumar, T
    Murugan, N
    PRAKTISCHE METALLOGRAPHIE-PRACTICAL METALLOGRAPHY, 2001, 38 (12): : 667 - 679
  • [5] Failure Analysis of an Inlet Pipe of a Governor Valve in a Steam Turbine of a District Heating System
    Chae, Hobyung
    Kim, Woo Cheol
    Kim, Heesan
    Kim, Jung-Gu
    Lee, Soo Yeol
    CORROSION SCIENCE AND TECHNOLOGY-KOREA, 2022, 21 (01): : 62 - 67
  • [6] Metallurgical Failure Analysis of a Fractured Steam Control Valve Stem
    Schroeder, Craig J.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2015, 15 (03) : 370 - 378
  • [7] Isolation Valve Impact on Failure Severity and Risk Analysis
    Hwang, Hwee
    Lansey, Kevin
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2021, 147 (03)
  • [8] MULTIPHYSICS ANALYSIS SYSTEM FOR TUBE FAILURE ACCIDENT IN STEAM GENERATOR OF SODIUM-COOLED FAST REACTOR
    Uchibori, Akihiro
    Kikuchi, Shin
    Kurihara, Akikazu
    Hamada, Hirotsugu
    Ohshima, Hiroyuki
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 3, 2014,
  • [9] Analysis for vibration and noise problem of main steam isolation valve with pipelines
    Xu, Zheng
    Wang, De-Zhong
    Zhang, Ji-Ge
    Zhou, Wen-Xia
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2010, 44 (01): : 95 - 100
  • [10] FAILURE ANALYSIS OF STEAM-GENERATOR TUBES WITH DENTED AND WASTAGE CONFIGURATIONS
    REICH, M
    PRACHUKTAM, S
    CHANG, TY
    JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME, 1978, 100 (04): : 354 - 359