Absorption measurements using low coherence interferometry

被引:0
|
作者
Storen, T [1 ]
Östling, D [1 ]
Svaasand, LO [1 ]
Lokberg, OJ [1 ]
Lindmo, T [1 ]
机构
[1] NTNU, Dept Phys, N-7034 Trondheim, Norway
来源
OPTICAL AND IMAGING TECHNIQUES FOR BIOMONITORING IV, PROCEEDINGS OF | 1999年 / 3567卷
关键词
low coherence interferometry; white-light; reflectometry; absorption; oximetry;
D O I
10.1117/12.339178
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The basic use of Low Coherence Interferometry is measuring the intensity of light reflected from defined depths in a partially transparent object. The light back-scattered from a certain depth in the object carries information about the medium that it has passed through. Absorption and scattering attenuate the intensity of the light, and will thus reduce the interference signal from a given depth. One single interference measurement will not discriminate between attenuation due to absorption and scattering. However, by measuring the interference signal at several different wavelengths, discrimination between the two parameters is possible, if they vary differently with wavelength. Especially when measurements are performed in a wavelength region where the scattering coefficient is constant, measurements at two different wavelengths will give the difference in absorption at the two wavelengths. We present preliminary measurements on scattering and absorbing solutions showing a qualitative difference in absorption measured at 810 and 830 nm. As an absorbing solution we used a commercially available dye with an absorption maximum at 800 nm while intralipid was used to introduce scattering. The aim of our work is to measure the oxygenation saturation of blood through absorption measurements at different wavelengths using Low Coherence Interferometry.
引用
收藏
页码:130 / 138
页数:9
相关论文
共 50 条
  • [41] Differential length measurement using low coherence coupled tandem interferometry
    Smith, Martin D.
    MacPherson, William N.
    Maier, Robert R. J.
    OPTICAL SENSORS 2013, 2013, 8774
  • [42] Air refractive index measurement using low-coherence interferometry
    Pikalek, Tomas
    Buchta, Zdenek
    APPLIED OPTICS, 2015, 54 (16) : 5024 - 5030
  • [43] Damage detection in composite structures using polarimetric low coherence interferometry
    Mondanos, M
    Lloyd, PA
    Giles, IP
    Badcock, RA
    Weir, K
    14TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, 2000, 4185 : 760 - 763
  • [44] High-Performance Low Coherence Interferometry Using SSB Modulation
    Benitez, J.
    Bolea, M.
    Mora, J.
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2017, 29 (01) : 90 - 93
  • [45] Analyzing spatial correlations in tissue using angle-resolved low coherence interferometry measurements guided by co-located optical coherence tomography
    Kim, Sanghoon
    Heflin, Stephanie
    Kresty, Laura A.
    Halling, Meredith
    Perez, Laura N.
    Ho, Derek
    Crose, Michael
    Brown, William
    Farsiu, Sina
    Arshavsky, Vadim
    Wax, Adam
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (04): : 1400 - 1414
  • [46] Interference effects in low coherence interferometry and optical coherence tomography
    Russell, CD
    Bullough, TJ
    Sudworth, CD
    OPTICS COMMUNICATIONS, 2006, 260 (01) : 355 - 362
  • [47] Comparability of anterior chamber depth measurements with partial coherence interferometry and optical low-coherence reflectometry in pseudophakic eyes
    Luft, Nikolaus
    Hirnschall, Nino
    Farrokhi, Sanaz
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (08): : 1678 - 1684
  • [48] Comparison of Anterior Segment Measurements with Optical Low-coherence Reflectometry and Partial-coherence Interferometry Optical Biometers
    Can, Ertugrul
    Duran, Mustafa
    Cetinkaya, Tugba
    Ariturk, Nursen
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2016, 23 (04) : 288 - 292
  • [49] Fiber-Optic Differential Absorption Low Coherence Interferometry Technique for Sensing Glucose Selectively
    John, Pauline
    Vasa, Nilesh J.
    Sujatha, N.
    2020 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2020,
  • [50] Glucose sensing in oral mucosa simulating phantom using differential absorption based frequency domain low-coherence interferometry
    John, Pauline
    Vasa, Nilesh J.
    Unni, Sujatha Narayanan
    Rao, Suresh R.
    APPLIED OPTICS, 2017, 56 (29) : 8257 - 8265