Biomechanical analysis of a novel hook-screw technique for C1-2 stabilization Technical note

被引:4
|
作者
Reis, Marco Tulio [1 ]
Nottmeier, Eric W. [2 ]
Reyes, Phillip M. [1 ]
Baek, Seungwon [1 ]
Crawford, Neil R. [1 ]
机构
[1] St Josephs Hosp, Barrow Neurol Inst, Spinal Biomech Lab, Dept Neurosurg Res, Phoenix, AZ 85013 USA
[2] Mayo Clin, Dept Neurosurg, Jacksonville, FL 32224 USA
关键词
atlantoaxial instability; cervical spine; stabilization; craniovertebral junction; cervical laminar hook; posterior stabilization; posterior cervical surgery; POSTERIOR FIXATION TECHNIQUES; ATLANTOAXIAL FIXATION; OCCIPITOCERVICAL FUSION; POLYAXIAL SCREW; IN-VITRO; INSTRUMENTATION; SPINE; STABILITY; PEDICLE; PLATE;
D O I
10.3171/2012.5.SPINE1242
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The Food and Drug Administration has not cleared the following medical devices for the use described in this study. The following medical devices are being discussed for an off-label use: cervical lateral mass screws. Object. As an alternative for cases in which the anatomy and spatial relationship between C-2 and a vertebral artery precludes insertion of C-2 pedicle/pars or C1-2 transarticular screws, a technique that includes opposing laminar hooks (claw) at C-2 combined with C-1 lateral mass screws may be used. The biomechanical stability of this alternate technique was compared with that of a standard screw-rod technique in vitro. Methods. Flexibility tests were performed in 7 specimens (occiput to C-3) in the following 6 different conditions: 1) intact; 2) after creating instability and attaching a posterior cable/graft at C1-2; 3) after removing the graft and attaching a construct comprising C-1 lateral mass screws and C-2 laminar claws; 4) after reattaching the posterior cable-graft at C1-2 (posterior hardware still in place); 5) after removing the posterior cable-graft and laminar hooks and placing C-2 pedicle screws interconnected to C-1 lateral mass screws via rod; and 6) after reattaching the posterior cable-graft at C1-2 (screw-rod construct still in place). Results. All types of stabilization significantly reduced the range of motion, lax zone, and stiff zone compared with the intact condition. There was no significant biomechanical difference in terms of range of motion or lax zone between the screw-rod construct and the screw-claw-rod construct in any direction of loading. Conclusions. The screw-claw-rod technique restricts motion much like the standard Harms technique, making it an acceptable alternative technique when aberrant arterial anatomy precludes the placement of C-2 pars/pedicle screws or C1-2 transarticular screws. (http :thejns.org/doi/abs/10.3171/2012.5.SPINE1242)
引用
收藏
页码:220 / 226
页数:7
相关论文
共 50 条
  • [41] Biomechanical Analysis Comparing Three C1-C2 Transarticular Screw Salvaging Fixation Techniques
    Elgafy, Hossein
    Potluri, Tejaswy
    Goel, Vijay K.
    Foster, Scott
    Faizan, Ahmad
    Kulkarni, Nikhil
    SPINE, 2010, 35 (04) : 378 - 385
  • [42] Odontoid Synchondrosis Fracture Treated by C1-2 Polyaxial Screw-Rod Fixation
    Muthukumar, Natarajan
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2014, 55 (04) : 212 - 214
  • [43] Clenching Reduction Technique for Osteosynthesis of Atypical C2 Fractures with the Combining Use of Laminar and Pedicle Screw: A Technical Note
    Lee, Suk-Joong
    Min, Woo-Kie
    Lee, Hyun-Joo
    Mun, Jong-Uk
    Choi, Ji-Yeon
    JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2018, 79 (02) : 169 - 172
  • [44] C1-C2 pedicle screw fixation with rigid cantilever beam construct: Case report and technical note
    Resnick, DK
    Benzel, EC
    NEUROSURGERY, 2002, 50 (02) : 426 - 428
  • [46] Anterior transarticular C1-C2 fixation with contralateral screw insertion: a report of two cases and technical note
    Lvov, Ivan
    Grin, Andrey
    Kaykov, Aleksandr
    Smirnov, Vladimir
    Krylov, Vladimir
    EUROPEAN SPINE JOURNAL, 2018, 27 : S347 - S352
  • [47] Freehand C2 Laminar Screw Placement: Technical Note and Operative Video
    Clifton, William
    Garcia, Jose O.
    Damon, Aaron
    Abode-Iyamah, Kingsley
    Pichelmann, Mark
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (09)
  • [48] PREOPERATIVE OBLIQUE AXIAL COMPUTED TOMOGRAPHIC IMAGING FOR C1-C2 TRANSARTICULAR SCREW FIXATION - TECHNICAL NOTE
    DULL, ST
    TOSELLI, RM
    NEUROSURGERY, 1995, 37 (01) : 150 - 151
  • [49] C2 Nerve Root Resection to Achieve Safe and Wide Exposure of Lateral Atlantoaxial Joints in Posterior C1-2 Instrumented Fixation: Technical Note
    Yamagata, Toru
    Takami, Toshihiro
    Naito, Kentaro
    Ohata, Kenji
    NEUROLOGIA MEDICO-CHIRURGICA, 2013, 53 (12) : 914 - 919
  • [50] C1 Lateral Mass Screw Insertion With Protection of C1-C2 Venous Sinus Technical Note and Review of the Literature
    Pan, Jie
    Li, Lijun
    Qian, Lie
    Tan, Jun
    Sun, Guixin
    Li, Xin
    SPINE, 2010, 35 (21) : E1133 - E1136