atlantoaxial instability; cervical spine; stabilization; craniovertebral junction; cervical laminar hook; posterior stabilization; posterior cervical surgery; POSTERIOR FIXATION TECHNIQUES; ATLANTOAXIAL FIXATION; OCCIPITOCERVICAL FUSION; POLYAXIAL SCREW; IN-VITRO; INSTRUMENTATION; SPINE; STABILITY; PEDICLE; PLATE;
D O I
10.3171/2012.5.SPINE1242
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The Food and Drug Administration has not cleared the following medical devices for the use described in this study. The following medical devices are being discussed for an off-label use: cervical lateral mass screws. Object. As an alternative for cases in which the anatomy and spatial relationship between C-2 and a vertebral artery precludes insertion of C-2 pedicle/pars or C1-2 transarticular screws, a technique that includes opposing laminar hooks (claw) at C-2 combined with C-1 lateral mass screws may be used. The biomechanical stability of this alternate technique was compared with that of a standard screw-rod technique in vitro. Methods. Flexibility tests were performed in 7 specimens (occiput to C-3) in the following 6 different conditions: 1) intact; 2) after creating instability and attaching a posterior cable/graft at C1-2; 3) after removing the graft and attaching a construct comprising C-1 lateral mass screws and C-2 laminar claws; 4) after reattaching the posterior cable-graft at C1-2 (posterior hardware still in place); 5) after removing the posterior cable-graft and laminar hooks and placing C-2 pedicle screws interconnected to C-1 lateral mass screws via rod; and 6) after reattaching the posterior cable-graft at C1-2 (screw-rod construct still in place). Results. All types of stabilization significantly reduced the range of motion, lax zone, and stiff zone compared with the intact condition. There was no significant biomechanical difference in terms of range of motion or lax zone between the screw-rod construct and the screw-claw-rod construct in any direction of loading. Conclusions. The screw-claw-rod technique restricts motion much like the standard Harms technique, making it an acceptable alternative technique when aberrant arterial anatomy precludes the placement of C-2 pars/pedicle screws or C1-2 transarticular screws. (http :thejns.org/doi/abs/10.3171/2012.5.SPINE1242)
引用
收藏
页码:220 / 226
页数:7
相关论文
共 50 条
  • [21] Anterior retropharyngeal fixation C1-2 for stabilization of atlantoaxial instabilities: study of feasibility, technical description and preliminary results
    Heiko Koller
    Volker Kammermeier
    Dietmar Ulbricht
    Allan Assuncao
    Stefan Karolus
    Boris van den Berg
    Ulrich Holz
    European Spine Journal, 2006, 15 : 1326 - 1338
  • [22] The optimal transarticular C1-2 screw length and the location of the hypoglossal nerve
    Ebraheim, NA
    Misson, JR
    Xu, RM
    Yeasting, RA
    SURGICAL NEUROLOGY, 2000, 53 (03): : 208 - 210
  • [23] Anatomical suitability of C1-2 transarticular screw placement in pediatric patient
    Brockmeyer, DL
    York, JE
    Apfelbaum, RI
    JOURNAL OF NEUROSURGERY, 2000, 92 (01) : 7 - 11
  • [24] Anterior retropharyngeal fixation C1-2 for stabilization of atlantoaxial instabilities: study of feasibility, technical description and preliminary results
    Koller, Heiko
    Kammermeier, Volker
    Ulbricht, Dietmar
    Assuncao, Allan
    Karolus, Stefan
    van den Berg, Boris
    Holz, Ulrich
    EUROPEAN SPINE JOURNAL, 2006, 15 (09) : 1326 - 1338
  • [25] Stabilization of the Atlantoaxial Joint With C1-C3 Lateral Mass Screw Constructs: Biomechanical Comparison With Standard Technique COMMENTS
    Benzel, Edward C.
    Bisson, Erica F.
    NEUROSURGERY, 2010, 67
  • [26] Effect of frameless stereotaxy on the accuracy of C1-2 transarticular screw placement
    Bloch, O
    Holly, LT
    Park, J
    Obasi, C
    Kim, K
    Johnson, JP
    JOURNAL OF NEUROSURGERY, 2001, 95 (01) : 74 - 79
  • [27] Pediatric Stereotactic Image-guided C1-2 Transarticular Screw Placement
    Prablek, Marc A.
    LoPresti, Melissa
    Bauer, David
    JOURNAL OF NEUROSURGERY, 2022, 136 (05)
  • [28] NEW SURGICAL TECHNIQUE FOR ATLANTO-AXIAL INSTABILITY: C1-2 DORSAL FIXATION WITH THE SCREW-ROD SYSTEM
    Lipoth Laszlo
    Banczerowski Peter
    Veres Robert
    IDEGGYOGYASZATI SZEMLE-CLINICAL NEUROSCIENCE, 2010, 63 (7-8): : 252 - 258
  • [29] The optimal transarticular C1-2 screw length and the location of the hypoglossal nerve - Commentary
    Wagner, FC
    SURGICAL NEUROLOGY, 2000, 53 (03): : 210 - 210
  • [30] Atlantoaxial fusion using anterior transarticular screw fixation of C1-C2: technical innovation and biomechanical study
    Sen, MK
    Steffen, T
    Beckman, L
    Tsantrizos, A
    Reindl, R
    Aebi, M
    EUROPEAN SPINE JOURNAL, 2005, 14 (05) : 512 - 518