Biomechanics of implant augmentation

被引:0
|
作者
Windolf, M. [1 ]
机构
[1] AO Forschungsinst Davos, CH-7270 Davos, Switzerland
来源
UNFALLCHIRURG | 2015年 / 118卷 / 09期
关键词
Augmentation; Cement; Implant; Osteoporosis; PMMA; CEMENT AUGMENTATION; IN-VITRO; TEMPERATURE EVALUATION; SCREW AUGMENTATION; OSTEOPOROTIC BONE; FRACTURES; FAILURE; PLATE; MANAGEMENT; FIXATION;
D O I
10.1007/s00113-015-0050-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The rising incidence of osteoporotic fractures requires novel treatment strategies. Implant augmentation with bone cement is considered to be a promising approach but the benefits and risks need to be carefully evaluated. Experimental investigation of the biomechanical potential and the associated risks with special reference to the osteoporotic proximal femur and proximal humerus. Even small amounts of bone cement (3 ml) applied to the proximal femur in combination with intramedullary nailing led to more than a 50 % increase in the number of test cycles before failure. The heat and pressure generated in the bone did not exceed critical thresholds. Short to midterm effects of subchondral cement placement on the adjacent cartilage can be excluded. The risk for cement leakage needs to be considered. Implant augmentation offers high biomechanical potential to prevent mechanical complications after fracture fixation in osteoporotic bone. Early and confident mobilization of elderly patients therefore appears to be possible. With appropriate handling, associated risks seem controllable; however, implant augmentation cannot be applied as a routine concept for osteoporotic fracture management. The application requires careful evaluation on a case by case basis under comprehensive consideration of mechanical and biological factors.
引用
收藏
页码:765 / 771
页数:7
相关论文
共 50 条
  • [41] Biomechanics of Different Types of PEEK as Implant Materials for Implant-Retained Mandibular Overdentures
    Hassan, Nermeen A.
    Elkhadem, Amr H.
    Elkerdawy, Maha W.
    Osman, Reham B.
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2022, 30 (02): : 113 - 120
  • [42] Lateral ridge augmentation and implant placement: An experimental study evaluating implant osseointegration in different augmentation materials in the canine mandible
    von Arx, T
    Cochran, DL
    Hermann, JS
    Schenk, RK
    Higginbottom, FL
    Buser, D
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2001, 16 (03) : 343 - 354
  • [43] Cement augmentation and bone graft substitutes-Materials and biomechanics
    Gueorguiev, Boyko
    Lenz, Mark
    UNFALLCHIRURGIE, 2022, 125 (06): : 430 - 435
  • [44] Restoring Segmental Biomechanics Through Nucleus Augmentation An In Vitro Study
    Pelletier, Matthew H.
    Cohen, Charles S.
    Ducheyne, Paul
    Walsh, William R.
    CLINICAL SPINE SURGERY, 2016, 29 (10): : 461 - 467
  • [45] Bone Augmentation for Implant Placement: Recent Advances
    Van Viet Dam
    Hai Anh Trinh
    Rokaya, Dinesh
    Dinh Hai Trinh
    INTERNATIONAL JOURNAL OF DENTISTRY, 2022, 2022
  • [46] Augmentation phalloplasty: "Apical and pericavernousal penile implant"
    Salhi, J.
    Del Prete, M.
    JOURNAL OF SEXUAL MEDICINE, 2008, 5 : 67 - 68
  • [47] Augmentation of shoulder contour using a calf implant
    Saray, A
    Eskandari, M
    Oztuna, V
    AESTHETIC PLASTIC SURGERY, 2000, 24 (05) : 386 - 388
  • [48] Augmentation of Shoulder Contour Using a Calf Implant
    Aydin Saray
    Metin Eskandari
    Volkan Oztuna
    Aesthetic Plastic Surgery, 2000, 24 : 386 - 388
  • [49] Delayed Implant Augmentation of Breast Free Flaps
    Pien, Irene J.
    Anolik, Rachel
    Blau, Jared
    Hollenbeck, Scott T.
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2015, 31 (04) : 254 - 260
  • [50] Augmentation mammaplasty: Where should the implant be placed?
    Takayanagi, S
    Nakagawa, C
    Sugimoto, Y
    AESTHETIC PLASTIC SURGERY, 2004, 28 (02) : 83 - 88