Resolution of a discrepancy of x-ray attenuation measurements of silicon in the energy range 25-50 keV

被引:13
|
作者
Chantler, CT [1 ]
Barnea, Z [1 ]
机构
[1] Univ Melbourne, Parkville, Vic 3052, Australia
关键词
D O I
10.1088/0953-8984/11/20/315
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
Precise measurements of the x-ray attenuation coefficient of crystalline silicon were made in the energy range 24 to 50 keV in 1985. As we show in this short paper, these measurements are of the highest precision currently available (1%-1.5%) for these energies. However, comparisons with theory were unable to resolve a residual discrepancy which reached seven standard deviations of the experimental precision over this range of energies. The most likely cause of the discrepancy was thought to lie in the estimation of the thermal diffuse scattering cross-section. We show that the dominant factor was, instead, the accuracy of the theory for the photoelectric component of the attenuation. Comparison with theory based on Chantler's work shows agreement with experiment to within one standard deviation.
引用
收藏
页码:4087 / 4091
页数:5
相关论文
共 50 条
  • [31] TOTAL X-RAY ATTENUATION COEFFICIENTS FROM 40 KEV TO 412 KEV
    WIEDENBECK, M
    PHYSICAL REVIEW, 1962, 126 (03): : 1009 - &
  • [32] The X-ray energy response of silicon .B. Measurements
    Owens, A
    Fraser, GW
    Abbey, AF
    Holland, A
    McCarthy, K
    Keay, A
    Wells, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 382 (03): : 503 - 510
  • [33] Experimental determination of the X-ray attenuation coefficient of In at 8.047 keV
    Ferrari, C
    Verdi, N
    Motta, A
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2005, 38 : 713 - 715
  • [34] X-ray monochromator with an energy resolution of 8x10-9 at 14.41 keV
    Yabashi, M
    Tamasaku, K
    Kikuta, S
    Ishikawa, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (11): : 4080 - 4083
  • [35] Study of the hydrothermal crystallization process of barium titanate by means of X-ray mass attenuation coefficient measurements at an energy of 59.54 keV
    Ozen, Songul Akbulut
    Ozen, Murat
    Sahin, Mehmet
    Mertens, Myrjam
    MATERIALS CHARACTERIZATION, 2017, 129 : 329 - 335
  • [36] Determination of the efficiency of an energy dispersive X-ray spectrometer up to 50 keV with a SEM
    Rackwitz, Vanessa
    Warrikhoff, Alexander
    Panne, Ulrich
    Hodoroaba, Vasile-Dan
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (08) : 1034 - 1036
  • [37] Simulating 50 keV X-ray Photon Detection in Silicon with a Down-Conversion Layer
    Anagnost, Kaitlin M.
    Lee, Eldred
    Wang, Zhehui
    Liu, Jifeng
    Fossum, Eric R.
    SENSORS, 2021, 21 (22)
  • [38] X-RAY ATTENUATION-COEFFICIENT MEASUREMENTS
    MCCRARY, JH
    PLASSMANN, EH
    PUCKETT, JM
    CONNER, AL
    ZIMMERMAN, GW
    PHYSICAL REVIEW, 1967, 153 (02): : 307 - +
  • [39] X-RAY SURVEY OF CYGNUS REGION IN 20-300 KEV ENERGY RANGE
    MATTESON, JL
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (04): : 635 - &
  • [40] A FOCUSING X-RAY TELESCOPE FOR USE IN STUDY OF EXTRATERRESTRIAL X-RAY SOURCES IN ENERGY RANGE 20-140 KEV
    LINDQUIST, TR
    WEBBER, WR
    CANADIAN JOURNAL OF PHYSICS, 1968, 46 (10P4) : 1103 - +