Resolution of a discrepancy of x-ray attenuation measurements of silicon in the energy range 25-50 keV

被引:13
|
作者
Chantler, CT [1 ]
Barnea, Z [1 ]
机构
[1] Univ Melbourne, Parkville, Vic 3052, Australia
关键词
D O I
10.1088/0953-8984/11/20/315
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
Precise measurements of the x-ray attenuation coefficient of crystalline silicon were made in the energy range 24 to 50 keV in 1985. As we show in this short paper, these measurements are of the highest precision currently available (1%-1.5%) for these energies. However, comparisons with theory were unable to resolve a residual discrepancy which reached seven standard deviations of the experimental precision over this range of energies. The most likely cause of the discrepancy was thought to lie in the estimation of the thermal diffuse scattering cross-section. We show that the dominant factor was, instead, the accuracy of the theory for the photoelectric component of the attenuation. Comparison with theory based on Chantler's work shows agreement with experiment to within one standard deviation.
引用
收藏
页码:4087 / 4091
页数:5
相关论文
共 50 条
  • [21] ATTENUATION MEASUREMENTS IN THE X-RAY REGION
    VARIER, KM
    UNNIKRISHNAN, MP
    PHYSICAL REVIEW A, 1986, 33 (04): : 2382 - 2386
  • [22] Energy dispersion of X-ray continua in the energy range 8 keV to 16 keV by refraction on Si wafers
    Ebel, H
    Streli, C
    Pepponi, G
    Wobrauschek, P
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (11) : 2045 - 2048
  • [23] Characterizations of MCP performance in the hard x-ray range (6-25 keV)
    Wu, Ming
    Moy, Ken
    Kruschwitz, Craig
    Rochau, Greg
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [24] MEASUREMENT OF PRIMARY X-RAY DIFFUSE COMPONENT IN RANGE FROM 25 TO 200 KEV
    HORSTMANMORETTI, E
    FULIGNI, F
    BRINI, D
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA B, 1971, B 6 (01): : 68 - +
  • [25] RESULTS OF AN X-RAY SCANNING OF SKY IN 20 - 200 KEV ENERGY RANGE
    BRINI, D
    CATTANI, D
    CIRIEGI, U
    FULIGNI, F
    GALLI, M
    GANDOLFI, A
    MORETTI, E
    SACCHI, C
    ANNALES D ASTROPHYSIQUE, 1965, 28 (06): : 1034 - &
  • [26] Measurement of the X-ray mass attenuation coefficients of silver in the 5-20 keV range
    Islam, M. Tauhidul
    Tantau, Lachlan J.
    Rae, Nicholas A.
    Barnea, Zwi
    Tran, Chanh Q.
    Chantler, Christopher T.
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 413 - 423
  • [27] Eight-channel x-ray spectrometer for 0.2-1.5 keV energy range with high time and energy resolution
    Bessarab, AV
    Grigorovitch, SV
    Intyapin, VV
    Kundicov, VI
    Kunin, AV
    Tokarev, VA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (01): : 82 - 87
  • [28] COSMIC X-RAY SOURCES IN 20-180 KEV ENERGY RANGE
    BRINI, D
    CIRIEGI, U
    FULIGNI, F
    MORETTI, E
    VESPIGNA.G
    ASTROPHYSICAL JOURNAL, 1967, 149 (2P1): : 429 - &
  • [29] X-RAY ATTENUATION COEFFICIENTS AND PHOTOELECTRIC CROSS-SECTIONS OF CU AND FE IN THE RANGE 3 KEV TO 29 KEV
    WANG, DC
    DING, XL
    WANG, XF
    YANG, H
    ZHOU, HY
    SHEN, XY
    ZHU, GH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 71 (03): : 241 - 248
  • [30] THE EVALUATION OF SILICON CCDS FOR IMAGING X-RAY SPECTROSCOPY IN THE RANGE 1 TO 8 KEV
    GRIFFITHS, RE
    ADVANCES IN IMAGING AND ELECTRON PHYSICS, 1985, 64 : 483 - 496