Resolution of a discrepancy of x-ray attenuation measurements of silicon in the energy range 25-50 keV

被引:13
|
作者
Chantler, CT [1 ]
Barnea, Z [1 ]
机构
[1] Univ Melbourne, Parkville, Vic 3052, Australia
关键词
D O I
10.1088/0953-8984/11/20/315
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
Precise measurements of the x-ray attenuation coefficient of crystalline silicon were made in the energy range 24 to 50 keV in 1985. As we show in this short paper, these measurements are of the highest precision currently available (1%-1.5%) for these energies. However, comparisons with theory were unable to resolve a residual discrepancy which reached seven standard deviations of the experimental precision over this range of energies. The most likely cause of the discrepancy was thought to lie in the estimation of the thermal diffuse scattering cross-section. We show that the dominant factor was, instead, the accuracy of the theory for the photoelectric component of the attenuation. Comparison with theory based on Chantler's work shows agreement with experiment to within one standard deviation.
引用
收藏
页码:4087 / 4091
页数:5
相关论文
共 50 条
  • [1] X-RAY ATTENUATION OF SILICON IN THE ENERGY-RANGE 25-50 KEV
    MIKA, JF
    MARTIN, LJ
    BARNEA, Z
    JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1985, 18 (26): : 5215 - 5223
  • [2] X-RAY ATTENUATION IN SILICON AND GERMANIUM IN ENERGY-RANGE 25 TO 50 KEV
    GERWARD, L
    THUESEN, G
    ZEITSCHRIFT FUR NATURFORSCHUNG SECTION A-A JOURNAL OF PHYSICAL SCIENCES, 1977, 32 (06): : 588 - 593
  • [3] X-RAY ATTENUATION COEFFICIENTS FOR COPPER IN THE ENERGY-RANGE 5 TO 50 KEV
    GERWARD, L
    ZEITSCHRIFT FUR NATURFORSCHUNG SECTION A-A JOURNAL OF PHYSICAL SCIENCES, 1982, 37 (05): : 451 - 459
  • [4] Measurement of the x-ray mass attenuation coefficients of gold in the 38-50-keV energy range
    Islam, M. T.
    Rae, N. A.
    Glover, J. L.
    Barnea, Z.
    de Jonge, M. D.
    Tran, C. Q.
    Wang, J.
    Chantler, C. T.
    PHYSICAL REVIEW A, 2010, 81 (02):
  • [5] High resolution spectrometer for extended x-ray absorption fine structure measurements in the 6 keV to 15 keV energy range
    Seely, J. F.
    Hudson, L. T.
    Henins, Albert
    Feldman, U.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [6] X-RAY LINEAR ABSORPTION-COEFFICIENTS FOR SILICON AND GERMANIUM IN THE ENERGY-RANGE 5 TO 50 KEV
    HILDEBRANDT, G
    ACTA CRYSTALLOGRAPHICA SECTION A, 1979, 35 (JUL): : 696 - 697
  • [7] X-RAY ATTENUATION COEFFICIENTS OF BERYLLIUM IN THE ENERGY-RANGE 5 TO 20 KEV
    GERWARD, L
    ACTA CRYSTALLOGRAPHICA SECTION A, 1989, 45 : 1 - 3
  • [8] X-RAY ATTENUATION COEFFICIENTS OF CARBON IN THE ENERGY-RANGE 5 TO 20 KEV
    GERWARD, L
    ACTA CRYSTALLOGRAPHICA SECTION A, 1983, 39 (MAY): : 322 - 325
  • [9] Energy resolution for accurate measurements of the X-ray linear attenuation coefficient
    Midgley, S.
    RADIATION PHYSICS AND CHEMISTRY, 2006, 75 (09) : 936 - 944
  • [10] MEASUREMENTS OF THE X-RAY MASS ATTENUATION COEFFICIENTS FORSOME MIXTURES IN THE ENERGY RANGE 5-12 KEV.
    CANNATA, A.
    ESPOSITO, A.
    PELLICCIONI, M.
    1982, V 67 (N 6): : 167 - 170