Dose optimization for dual-energy contrast-enhanced digital mammography based on an energy-resolved photon-counting detector: A Monte Carlo simulation study

被引:5
|
作者
Lee, Youngjin [1 ]
Lee, Seungwan [2 ,3 ]
Kang, Sooncheol [3 ]
Eom, Jisoo [2 ]
机构
[1] Eulji Univ, Coll Hlth Sci, Dept Radiol Sci, 553 Sanseong Daero, Seongnam 13135, Gyeonggi Do, South Korea
[2] Konyang Univ, Coll Med Sci, Dept Radiol Sci, 158 Gwanjeodong Ro, Daejeon 35365, South Korea
[3] Konyang Univ, Dept Med Sci, 158 Gwanjeodong Ro, Daejeon 35365, South Korea
基金
新加坡国家研究基金会;
关键词
Dual-energy imaging; Photon-counting detector; Contrast-enhanced digital mammography; Radiation dose; Monte Carlo simulation; ADDITIONAL SPECTRAL FILTRATION; SOURCE CT; COMPUTED-TOMOGRAPHY; FEASIBILITY; NOISE; DIFFERENTIATION; QUANTIFICATION; RADIOGRAPHY; CALIBRATION; TISSUE;
D O I
10.1016/j.radphyschem.2016.11.016
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Dual-energy contrast-enhanced digital mammography (CEDM) has been used to decompose breast images and improve diagnostic accuracy for tumor detection. However, this technique causes an increase of radiation dose and an inaccuracy in material decomposition due to the limitations of conventional X-ray detectors. In this study, we simulated the dual-energy CEDM with an energy-resolved photon-counting detector (ERPCD) for reducing radiation dose and improving the quantitative accuracy of material decomposition images. The ERPCD-based dual-energy CEDM was compared to the conventional dual-energy CEDM in terms of radiation dose and quantitative accuracy. The correlation between radiation dose and image quality was also evaluated for optimizing the ERPCD-based dual-energy CEDM technique. The results showed that the material decomposition errors of the ERPCD-based dual-energy CEDM were 0.56-0.67 times lower than those of the conventional dual-energy CEDM. The imaging performance of the proposed technique was optimized at the radiation dose of 1.09 mGy, which is a half of the MGD for a single view mammogram. It can be concluded that the ERPCD-based dual-energy CEDM with an optimal exposure level is able to improve the quality of material decomposition images as well as reduce radiation dose.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 50 条
  • [31] Establishing a Quality Control protocol for dual-energy based contrast-enhanced digital mammography
    Cockmartin, L.
    Bosmans, H.
    Marshall, N. W.
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [32] Scatter-to-primary ratio and grid performance in contrast-enhanced dual-energy digital mammography using Monte Carlo simulations
    Cunha, D. M.
    Godeli, J.
    Poletti, M. E.
    RADIATION PHYSICS AND CHEMISTRY, 2025, 232
  • [33] Energy-resolved CT imaging with a photon-counting silicon-strip detector
    Persson, Mats
    Huber, Ben
    Karlsson, Staffan
    Liu, Xuejin
    Chen, Han
    Xu, Cheng
    Yveborg, Moa
    Bornefalk, Hans
    Danielsson, Mats
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (22): : 6709 - 6727
  • [34] A scatter correction method for dual-energy digital mammography: Monte Carlo simulation
    Ai, Kai
    Gao, Yanhua
    Yu, Gang
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (05) : 653 - 671
  • [35] Preliminary Evaluation of A Novel Energy-Resolved Photon-Counting Gamma Ray Detector
    Meng, L. J.
    Tan, J. W.
    Spartiotis, K.
    Schulman, T.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5115 - +
  • [36] Energy-resolved CT imaging with a photon-counting silicon-strip detector
    Persson, Mats
    Huber, Ben
    Karlsson, Staffan
    Liu, Xuejin
    Chen, Han
    Xu, Cheng
    Yveborg, Moa
    Bornefalk, Hans
    Danielsson, Mats
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [37] Preliminary evaluation of a novel energy-resolved photon-counting gamma ray detector
    Meng, L. -J.
    Tan, J. W.
    Spartiotis, K.
    Schulman, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (03): : 548 - 554
  • [38] Dual-energy contrast-enhanced spectral mammography (CESM)
    Daniaux, Martin
    De Zordo, Tobias
    Santner, Wolfram
    Amort, Birgit
    Koppelstaetter, Florian
    Jaschke, Werner
    Dromain, Clarisse
    Oberaigner, Willi
    Hubalek, Michael
    Marth, Christian
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2015, 292 (04) : 739 - 747
  • [39] Motion artifacts in dual-energy contrast-enhanced mammography
    Allec, Nicholas
    Abbaszadeh, Shiva
    Lewin, John M.
    Karim, Karim S.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [40] Dual-energy contrast-enhanced spectral mammography (CESM)
    Martin Daniaux
    Tobias De Zordo
    Wolfram Santner
    Birgit Amort
    Florian Koppelstätter
    Werner Jaschke
    Clarisse Dromain
    Willi Oberaigner
    Michael Hubalek
    Christian Marth
    Archives of Gynecology and Obstetrics, 2015, 292 : 739 - 747