Dose optimization for dual-energy contrast-enhanced digital mammography based on an energy-resolved photon-counting detector: A Monte Carlo simulation study

被引:5
|
作者
Lee, Youngjin [1 ]
Lee, Seungwan [2 ,3 ]
Kang, Sooncheol [3 ]
Eom, Jisoo [2 ]
机构
[1] Eulji Univ, Coll Hlth Sci, Dept Radiol Sci, 553 Sanseong Daero, Seongnam 13135, Gyeonggi Do, South Korea
[2] Konyang Univ, Coll Med Sci, Dept Radiol Sci, 158 Gwanjeodong Ro, Daejeon 35365, South Korea
[3] Konyang Univ, Dept Med Sci, 158 Gwanjeodong Ro, Daejeon 35365, South Korea
基金
新加坡国家研究基金会;
关键词
Dual-energy imaging; Photon-counting detector; Contrast-enhanced digital mammography; Radiation dose; Monte Carlo simulation; ADDITIONAL SPECTRAL FILTRATION; SOURCE CT; COMPUTED-TOMOGRAPHY; FEASIBILITY; NOISE; DIFFERENTIATION; QUANTIFICATION; RADIOGRAPHY; CALIBRATION; TISSUE;
D O I
10.1016/j.radphyschem.2016.11.016
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Dual-energy contrast-enhanced digital mammography (CEDM) has been used to decompose breast images and improve diagnostic accuracy for tumor detection. However, this technique causes an increase of radiation dose and an inaccuracy in material decomposition due to the limitations of conventional X-ray detectors. In this study, we simulated the dual-energy CEDM with an energy-resolved photon-counting detector (ERPCD) for reducing radiation dose and improving the quantitative accuracy of material decomposition images. The ERPCD-based dual-energy CEDM was compared to the conventional dual-energy CEDM in terms of radiation dose and quantitative accuracy. The correlation between radiation dose and image quality was also evaluated for optimizing the ERPCD-based dual-energy CEDM technique. The results showed that the material decomposition errors of the ERPCD-based dual-energy CEDM were 0.56-0.67 times lower than those of the conventional dual-energy CEDM. The imaging performance of the proposed technique was optimized at the radiation dose of 1.09 mGy, which is a half of the MGD for a single view mammogram. It can be concluded that the ERPCD-based dual-energy CEDM with an optimal exposure level is able to improve the quality of material decomposition images as well as reduce radiation dose.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 50 条
  • [21] Optimization of a dual-energy contrast-enhanced technique for a photon-counting digital breast tomosynthesis system: I. A theoretical model
    Carton, Ann-Katherine
    Ullberg, Christer
    Lindman, Karin
    Acciavatti, Raymond
    Francke, Tom
    Maidment, Andrew D. A.
    MEDICAL PHYSICS, 2010, 37 (11) : 5896 - 5907
  • [22] Dual-energy contrast-enhanced digital mammography: Examination protocol
    Barra, F. R.
    Ribeiro, A. C.
    Mathieu, O. D.
    Rodrigues, A. C.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2014, 95 (03) : 351 - 352
  • [23] Dual-energy contrast-enhanced digital subtraction mammography: Feasibility
    Lewin, JM
    Isaacs, PK
    Vance, V
    Larke, FJ
    RADIOLOGY, 2003, 229 (01) : 261 - 268
  • [24] Contrast Enhance Digital Mammography Based On Photon-Counting Detector
    Lee, M.
    Lee, D.
    Kim, H.
    Kim, D.
    Kim, H.
    MEDICAL PHYSICS, 2018, 45 (06) : E517 - E517
  • [25] Radiation Dose Reduction with Optimal Energy Weighting for a Prototype Energy-Resolved Photon-Counting Si Strip Detector
    Ng, A. Lam
    Ding, H.
    Cho, H.
    Barber, W.
    Iwanczyk, J.
    Molloi, S.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [26] Dual-energy contrast-enhanced digital mammography: initial clinical results
    Dromain, Clarisse
    Thibault, Fabienne
    Muller, Serge
    Rimareix, Francoise
    Delaloge, Suzette
    Tardivon, Anne
    Balleyguier, Corinne
    EUROPEAN RADIOLOGY, 2011, 21 (03) : 565 - 574
  • [27] Contrast-enhanced dual-energy digital mammography in the evaluation of breast cancer
    Awad, Fatma Mohamed
    Ismaeil, Hanaa
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2014, 45 (02): : 591 - 595
  • [28] Dual-energy contrast-enhanced digital mammography: initial clinical results
    Clarisse Dromain
    Fabienne Thibault
    Serge Muller
    Françoise Rimareix
    Suzette Delaloge
    Anne Tardivon
    Corinne Balleyguier
    European Radiology, 2011, 21 : 565 - 574
  • [29] Experimental Optimization of Photon-Counting Dual-Energy Angiography
    Aubert, S.
    Tanguay, J.
    MEDICAL PHYSICS, 2022, 49 (06) : E548 - E549
  • [30] Feasibility study of contrast enhanced digital mammography based on photon-counting detector by projection-based weighting technique: A simulation study
    Lee, Minjae
    Lee, Donghoon
    Jo, Byungdu
    Kim, Hyemi
    Kim, Dohyeon
    Choi, Seungyeon
    Kim, Hee-Joung
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573