Continuous glucose monitoring: quality of hypoglycaemia detection

被引:35
|
作者
Zijlstra, E. [1 ]
Heise, T. [1 ]
Nosek, L. [1 ]
Heinemann, L. [1 ]
Heckermann, S. [1 ]
机构
[1] Profil, Neuss, Germany
来源
DIABETES OBESITY & METABOLISM | 2013年 / 15卷 / 02期
关键词
clinical trial; glycaemic control; type; 1; diabetes; CLINICAL ACCURACY;
D O I
10.1111/dom.12001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To evaluate the accuracy of a (widely used) continuous glucose monitoring (CGM)-system and its ability to detect hypoglycaemic events. Methods A total of 18 patients with type 1 diabetes mellitus used continuous glucose monitoring (Guardian REAL-Time CGMS) during two 9-day in-house periods. A hypoglycaemic threshold alarm alerted patients to sensor readings <70?mg/dl. Continuous glucose monitoring sensor readings were compared to laboratory reference measurements taken every 4?h and in case of a hypoglycaemic alarm. Results A total of 2317 paired data points were evaluated. Overall, the mean absolute relative difference (MARD) was 16.7%. The percentage of data points in the clinically accurate or acceptable Clarke Error Grid zones A?+?B was 94.6%. In the hypoglycaemic range, accuracy worsened (MARD 38.8%) leading to a failure to detect more than half of the true hypoglycaemic events (sensitivity 37.5%). Furthermore, more than half of the alarms that warn patients for hypoglycaemia were false (false alert rate 53.3%). Above the low alert threshold, the sensor confirmed 2077 of 2182 reference values (specificity 95.2%). Conclusions Patients using continuous glucose monitoring should be aware of its limitation to accurately detect hypoglycaemia.
引用
收藏
页码:130 / 135
页数:6
相关论文
共 50 条
  • [41] Frequent and severe hypoglycaemia detected with continuous glucose monitoring in older institutionalised patients with diabetes
    Bouillet, Benjamin
    Tscherter, Pauline
    Vaillard, Laurence
    Nonciaux, Christine
    Hourdain, Philippe
    Ravier, Anne
    Rouland, Alexia
    Petit, Jean Michel
    Verges, Bruno
    Quilot, Emilienne
    AGE AND AGEING, 2021, 50 (06) : 2088 - 2093
  • [42] DIFFERENCES BETWEEN PATIENTS WITH AND WITHOUT NOCTURNAL HYPOGLYCAEMIA DETECTED ON CONTINUOUS GLUCOSE MONITORING (CGM)
    Yeoh, E.
    Koh, A.
    Poh, M.
    Lim, S. C.
    Sum, C. F.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A81 - A81
  • [43] SUSTAINED REDUCTIONS IN SEVERE HYPOGLYCAEMIA WITH CONTINUOUS GLUCOSE MONITORING: REAL LIFE CLINICAL EXPERIENCE
    Slattery, D.
    Iftikhar, M.
    Brackenridge, A.
    Hopkins, D.
    Amiel, S.
    Choudhary, P.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 : A105 - A106
  • [44] The use of continuous glucose monitoring in inherited metabolic diseases with hypoglycaemia - a real world review
    Newman, Christine
    Ellerton, Charlotte
    Nguyen, Patty
    Girling, James
    Lachmann, Robert
    Murphy, Elaine
    IRISH JOURNAL OF MEDICAL SCIENCE, 2024, 193 : S186 - S187
  • [45] CONTINUOUS GLUCOSE MONITORING DETECTED NOCTURNAL HYPOGLYCAEMIA IS ASSOCIATED WITH A LOWER SELF-REPORTED SLEEP QUALITY IN TYPE 1 DIABETES
    Gardner, D. S.
    Oo, M. Zin
    Lim, G. H.
    Xin, X.
    Tan, H. C.
    Chandran, S. Rama
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 : A223 - A223
  • [46] Associations of continuous glucose monitoring metrics and antepartum glucose with the risk of neonatal hypoglycaemia in women with type 1 diabetes
    Li, X.
    Gong, Y.
    Ling, P.
    Wang, C.
    Yan, J.
    Luo, S.
    Zheng, X.
    Yang, D.
    DIABETOLOGIA, 2023, 66 (SUPPL 1) : S260 - S260
  • [47] THE EFFECT OF RECENT EXPOSURE TO HYPOGLYCAEMIA ASSESSED BY CONTINUOUS GLUCOSE MONITORING ON COUNTERREGULATORY RESPONSES TO CONTROLLED HYPOGLYCAEMIA IN PEOPLE WITH TYPE 1 DIABETES
    Svensson, C.
    Fabricius, T.
    Verhulst, C.
    Kristensen, P.
    Tack, C.
    De Galan, B.
    Pedersen-Bjergaard, U.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 : A165 - A166
  • [48] A randomized controlled pilot study of continuous glucose monitoring and flash glucose monitoring in people with Type 1 diabetes and impaired awareness of hypoglycaemia
    Reddy, M.
    Jugnee, N.
    El Laboudi, A.
    Spanudakis, E.
    Anantharaja, S.
    Oliver, N.
    DIABETIC MEDICINE, 2018, 35 (04) : 483 - 490
  • [49] Continuous Glucose Monitoring: A Transformative Approach to the Detection of Prediabetes
    Liu, Xueen
    Zhang, Jiale
    JOURNAL OF MULTIDISCIPLINARY HEALTHCARE, 2024, 17 : 5513 - 5519
  • [50] Monitoring and Fault Detection of Continuous Glucose Sensor Measurements
    Turksoy, Kamuran
    Quinn, Laurie
    Littlejohn, Elizabeth
    Cinar, Ali
    2015 AMERICAN CONTROL CONFERENCE (ACC), 2015, : 5091 - 5096