Measurement of continuous cardiac output useful for the management of polytrauma patients?

被引:0
|
作者
Stiletto, R [1 ]
Hünerkopf, M [1 ]
Schnabel, M [1 ]
Gotzen, L [1 ]
Baacke, M [1 ]
机构
[1] Univ Marburg, Unfallchirurg Klin, D-35460 Marburg, Germany
来源
UNFALLCHIRURG | 2001年 / 104卷 / 11期
关键词
pulmonary artery catheter; CCO-monitoring; polytrauma;
D O I
10.1007/s001130170018
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose. Is the measurement of continuous cardiac output useful for the management of polytrauma patients? Methods. In a prospective non randomized study (ethic comission file 43/96) we evaluated the diagnostic and therapeutic impact of the CCO (continuous cardiac output measurement) for polytrauma patients on the ICU. The Baxter Vigilance System was used for measuring the continuous cardiac output. The CCO values were controlled once a day by the conventional "cold" thermodilution technique. Results. All values are given as mean standard deviation. The Patients were scored on the first day for ISS (injury severity score) (47 +/- 17) and APACHE II (15 +/- 5). The CCO was used no later than 12 hours after the initial treatment in 20 polytrauma patients. As clinical outcome parameters were chosen: days on ventilation (23 +/- 23 days), days on the ICU (31 +/- 26 days) and mortality (20%). The treating ICU physicians were asked in a standardized questionnaire, whether or not there was an impact of the CCO measurement on their therapy. Seven different surgeons were working with the system. Conclusion. The unique opinion was that the CCO device had an impact on their decision making in the fluid and drug management of the study patients. Our first experience, however, suggests that this device may become an important improvement in the management of haemodynamics in the early trauma phases. Before a wide-spread application of this method on the ICU an evidence based prospective randomized trial should be performed.
引用
收藏
页码:1043 / 1047
页数:5
相关论文
共 50 条
  • [31] Continuous cardiac output monitoring with pulse contour analysis: A comparison with lithium indicator dilution cardiac output measurement
    Pittman, J
    Bar-Yosef, S
    SumPing, J
    Sherwood, M
    Mark, J
    CRITICAL CARE MEDICINE, 2005, 33 (09) : 2015 - 2021
  • [32] Uncalibrated Radial and Femoral Arterial Pressure Waveform Analysis for Continuous Cardiac Output Measurement: An Evaluation in Cardiac Surgery Patients
    Hofer, Christoph K.
    Button, Danny
    Weibel, Luc
    Genoni, Michele
    Zollinger, Andreas
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2010, 24 (02) : 257 - 264
  • [33] Comparison of continuous cardiac output measurements in patients after cardiac surgery
    Mielck, F
    Buhre, W
    Hanekop, G
    Tirilomis, T
    Hilgers, R
    Sonntag, H
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2003, 17 (02) : 211 - 216
  • [34] PERIOPERATIVE CONTINUOUS CARDIAC-OUTPUT MEASUREMENT IN CARDIAC AND AORTIC-ANEURYSM SURGERY
    RIJPSTRA, TA
    GROOTES, P
    SCHEFFER, GJ
    DELANGE, JJ
    BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 : 9 - 9
  • [35] Cardiac output measurement in children: comparison of the Ultrasound Cardiac Output Monitor with thermodilution cardiac output measurement
    Walter Knirsch
    Oliver Kretschmar
    Maren Tomaske
    Kathrina Stutz
    Nicole Nagdyman
    Christian Balmer
    Achim Schmitz
    Dominique Béttex
    Felix Berger
    Urs Bauersfeld
    Markus Weiss
    Intensive Care Medicine, 2008, 34 : 1060 - 1064
  • [36] Cardiac output measurement in children:: comparison of the Ultrasound Cardiac Output Monitor with thermodilution cardiac output measurement
    Knirsch, Walter
    Kretschmar, Oliver
    Tomaske, Maren
    Stutz, Kathrina
    Nagdyman, Nicole
    Balmer, Christian
    Schmitz, Achim
    Bettex, Dominique
    Berger, Felix
    Bauersfeld, Urs
    Weiss, Markus
    INTENSIVE CARE MEDICINE, 2008, 34 (06) : 1060 - 1064
  • [37] ACCURACY OF CONTINUOUS PHOTOELECTRIC RECORDING OF DYE CURVES IN THE MEASUREMENT OF CARDIAC OUTPUT
    RICHARDSON, DW
    WYSO, EM
    HECHT, AM
    FITZPATRICK, DP
    CIRCULATION, 1958, 18 (04) : 770 - 771
  • [38] A CATHETER MOUNTED DOPPLER SYSTEM FOR THE CONTINUOUS MEASUREMENT OF CARDIAC-OUTPUT
    ROTH, AC
    KALITA, S
    SUCHY, H
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 1778 - 1778
  • [39] CONTINUOUS CARDIAC-OUTPUT MEASUREMENT - ASPECTS OF DOPPLER FREQUENCY ANALYSIS
    MACKAY, RS
    HECHTMAN, HB
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1975, BM22 (04) : 346 - 350
  • [40] Continuous measurement of cardiac output using stochastic system identification techniques
    Yelderman, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 5360 - 5362