The Impact of Flash Intensity on Retinal Vessel Oxygen Saturation Measurements Using Dual Wavelength Oximetry

被引:14
|
作者
Heitmar, Rebekka [1 ]
Cubbidge, Robert Peter [1 ]
机构
[1] Aston Univ, Sch Life & Hlth Sci, Birmingham B4 7ET, W Midlands, England
关键词
oximetry; dual wavelength; photography; ethnicity; pigmentation;
D O I
10.1167/iovs.12-10493
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To establish the optimal flash settings for retinal vessel oxygen saturation parameters using dual-wavelength imaging in a multiethnic group. METHODS. Twelve healthy young subjects (mean age 32 years [SD 7]; three Mediterranean, two South Asian, and seven Caucasian individuals) underwent retinal vessel oxygen saturation measurements using dual-wavelength oximetry, noncontact tonometry, and manual sphygmomanometry. In order to evaluate the impact of flash intensity, we obtained three images (fundus camera angle 30 degrees, ONH centered) per flash setting. Flash settings of the fundus camera were increased in steps of 2 (initial setting of 6 and the final of 22), which reflect logarithmic increasing intensities from 13.5 to 214 Watt seconds (Ws). RESULTS. Flash settings below 27 Ws were too low to obtain saturation measurements, whereas flash settings of more than 214 Ws resulted in overexposed images. Retinal arteriolar and venular oxygen saturation was comparable at flash settings of 27 to 76 Ws (arterioles' range: 85%-92%; venules' range: 45%-53%). Higher flash settings lead to increased saturation measurements in both retinal arterioles (up to 110%) and venules (up to 92%), with a more pronounced increase in venules. CONCLUSIONS. Flash intensity has a significant impact on retinal vessel oxygen saturation measurements using dual-wavelength retinal oximetry. High flash intensities lead to supranormal oxygen saturation measurements with a magnified effect in retinal venules compared with arteries. In addition to even retinal illumination, the correct flash setting is of paramount importance for clinical acquisition of images in retinal oximetry. We recommend flash settings between 27 to 76 Ws.
引用
收藏
页码:2807 / 2811
页数:5
相关论文
共 50 条
  • [21] Retinal vessel oxygen saturation and vessel diameter in retinitis pigmentosa
    Eysteinsson, Thor
    Hardarson, Sveinn H.
    Bragason, David
    Stefansson, Einar
    ACTA OPHTHALMOLOGICA, 2014, 92 (05) : 449 - 453
  • [22] Racial Disparity in Oxygen Saturation Measurements by Pulse Oximetry
    Jamali, Haya
    Castillo, Lauren T.
    Morgan, Chelsea Cosby
    Coult, Jason
    Muhammad, Janice L.
    Osobamiro, Oyinkansola O.
    Parsons, Elizabeth C.
    Adamson, Rosemary
    ANNALS OF THE AMERICAN THORACIC SOCIETY, 2022, 19 (12) : 1951 - 1964
  • [23] VALIDATION OF ARTERIAL OXYGEN-SATURATION MEASUREMENTS INUTERO USING PULSE OXIMETRY
    HARRIS, AP
    SENDAK, MJ
    CHUNG, DC
    RICHARDSON, CA
    AMERICAN JOURNAL OF PERINATOLOGY, 1993, 10 (03) : 250 - 254
  • [24] Analyzing diameter artifacts in oximetry measures of retinal oxygen saturation
    Arciero, Julia
    Beach, James
    Shoemaker, Benjamin C.
    Verticchio, Alice
    Siesky, Brent A.
    Harris, Alon
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [25] Normal limits of retinal oximetry and retinal venous oxygen saturation in atrophic diseases
    Olafsdottir, Olof Birna
    Hardarson, Sveinn Hakon
    Vandewalle, Evelien
    Eysteinsson, Thor
    Gottfredsdottir, Maria Soffia
    Van Keer, Karel
    Pinto, Luis Abegao
    Stalmans, Ingeborg
    Stefansson, Einar
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [26] Preoperative and postoperative measurements of retinal vessel oxygen saturation in patients with different grades of cataracts
    Chen, Hui
    Lin, Haotian
    Chen, Wan
    Zhang, Bo
    Xiang, Wu
    Gao, Qianying
    Chen, Weirong
    Liu, Yizhi
    ACTA OPHTHALMOLOGICA, 2017, 95 (06) : E436 - E442
  • [27] Reliability and Determinants of Retinal Vessel Oximetry Measurements in Healthy Eyes
    Yip, WanFen
    Siantar, Rosalynn
    Perera, Shamira A.
    Milastuti, Nia
    Ho, Kee Ka
    Tan, Bernard
    Wong, Tien Yin
    Cheung, Carol Y.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (11) : 7104 - 7110
  • [28] Potential measurement error from vessel reflex and multiple light paths in dual-wavelength retinal oximetry
    Beach, James M.
    Shoemaker, Benjamin
    Eckert, George J.
    Harris, Alon
    Siesky, Brent
    Arciero, Julia C.
    ACTA OPHTHALMOLOGICA, 2024, 102 (03) : e367 - e380
  • [29] Minimizing the influence of fundus pigmentation on retinal vessel oximetry measurements
    Smith, MH
    Denninghoff, KR
    Lompado, A
    Woodruff, JB
    Hillman, LW
    OPHTHALMIC TECHNOLOGIES XI, 2001, 4245 : 135 - 145
  • [30] Retinal Vessel Oxygen Saturation and Vessel Diameter in Inactive Graves Ophthalmopathy
    Yang, Xiaonan
    Huang, Danping
    Ai, Siming
    Liang, Xuanwei
    Zhao, Jing
    Fang, Lei
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2017, 33 (06): : 459 - 465