Semiconductor laser's on-line coherence calibration and testing of frequency stability

被引:1
|
作者
Zakharov, Yu. N. [1 ]
Popov, A. Yu. [2 ]
Tyurin, A. V. [2 ]
机构
[1] Univ Nizhni Novgorod, Radiophys Dept, 23 Gagarin Ave, Nizhnii Novgorod 603600, Russia
[2] Odessa Natl Univ, Sci Res Inst, UA-65025 Odessa, Ukraine
来源
8TH INTERNATIONAL CONFERENCE ON CORRELATION OPTICS | 2008年 / 7008卷
关键词
coherence function; multimode laser; holographic correlometry; ESPI;
D O I
10.1117/12.797111
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
One of the main constituent parts of optical coherent measuring apparatus is laser as source with stable performance of frequency, radiation intensity, and light beam uniformity. At present time semiconductor lasers are rather attractive devices in view of there low prices, small size, serviceability. Progress in its quality leads to including them not only in lightheads, but as lighting unit in measuring apparatus. In order to guarantee accuracy of measuring instruments, all parts of them must have stable performance, and in this respect semiconductor laser demand stabilization more that one characteristic quantity at once. And frequency stability on the one hand is overwhelmingly important for constancy of optical measuring instruments, on the other hand our investigations show that its regulatory control is very arduous task. Both holographic methods and phase modulated speckle interferometry clearly recognize smooth frequency shift and frequency jumping depending on pumping current and temperature. And for repeatability it's required to return both of them. So it is necessary laser frequency testing during working. For interferometric comparison circuit it is frequency variation that exerts influence on fringes pattern generation, so just this parameter should be traced in the course of measuring. Specially prepared test object, introduced in holographic scheme, allows to uncover frequency variation, if they had have place, and to reproduce coherence function of laser source. Complicated coherence function of semi conductor lasers can destroy interference pattern or foul the interpretation of it. So this coherence calibration is also very useful for results validity. Phase modulated speckle interferometry method allows to build phase correlation portraits. analogical to interferograms, hence multiwavelength contour generation masks the picture of intrinsic object information too. Both real wavelength change and nonresolution area, when coherence length is less then path-length difference, may be obtained with the help of known wedge incline near the measured object. Since measured and testing image will be entered at the same time, test results will be applied in interpretation of measurement results. Thus on-line testing of laser characteristic quantities allows using unstable sources and increasing of measurement precision.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Adaptive on-line frequency stabilization system for laser diodes based on genetic algorithm
    Hisatake, S
    Hamaguchi, N
    Kawamoto, T
    Sasaki, W
    IEICE TRANSACTIONS ON ELECTRONICS, 2003, E86C (10) : 2097 - 2102
  • [22] Towards On-line PMU-based Model Calibration for Look-ahead Frequency Analysis
    Quiroz, Juan
    Chavez, Elector
    2019 IEEE MILAN POWERTECH, 2019,
  • [23] Single steady frequency and narrow line width external cavity semiconductor laser
    Zhao, WR
    Jiang, PF
    Xie, FZ
    ADVANCED CHARACTERIZATION TECHNIQUES FOR OPTICS, SEMICONDUCTORS, AND NANOTECHNOLOGIES, 2003, 5188 : 389 - 393
  • [24] Research design on dynamic testing system of conveyer's rollers on-line
    Li Weihua
    Yang Qinjian
    Du Xiuju
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 3263 - 3266
  • [25] ACHIEVEMENTS OF THE QUANTUM NOISE LIMITED FREQUENCY STABILITY IN ALGAAS SEMICONDUCTOR-LASER
    TSUCHIDA, H
    TAKO, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1983, 22 (08): : L496 - L498
  • [26] Stability and self-stabilisation of single-frequency lasing in a semiconductor laser
    Batrak, DV
    Bogatov, AP
    Kamenets, FF
    QUANTUM ELECTRONICS, 2003, 33 (11) : 941 - 948
  • [27] On-line stability monitoring of BWR's using artificial neural networks
    Tambouratzis, T
    Antonopoulos-Domis, M
    ANNALS OF NUCLEAR ENERGY, 1999, 26 (14) : 1287 - 1302
  • [28] Use of non-linear Chua's circuit for on-line offset calibration of ADC
    Cabrini, A
    Maloberti, F
    Proceedings of the 2005 European Conference on Circuit Theory and Design, Vol 1, 2005, : 297 - 300
  • [29] Accurate on-line depth calibration with a laser interferometer during SIMS profiling on the Cameca IMS WF instrument
    Merkulov, A
    Merkulova, O
    de Chambost, E
    Schuhmacher, M
    APPLIED SURFACE SCIENCE, 2004, 231 : 954 - 958
  • [30] FREQUENCY STABILIZATION OF A GAAIAS SEMICONDUCTOR-LASER TO AN ABSORPTION-LINE OF IODINE VAPOR
    LUDVIGSEN, H
    HOLMLUND, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (04): : 2135 - 2137