Second External Quality Assurance Study for the Serological Diagnosis of Hantaviruses in Europe

被引:12
|
作者
Escadafal, Camille [1 ,2 ]
Avsic-Zupanc, Tatjana [3 ]
Vapalahti, Olli [4 ]
Niklasson, Bo [5 ,6 ]
Teichmann, Anette [1 ]
Niedrig, Matthias [1 ]
Donoso-Mantke, Oliver [1 ]
机构
[1] Robert Koch Inst, ZBS 1, Berlin, Germany
[2] European Ctr Dis Prevent & Control ECDC, European Publ Hlth Microbiol Training Programme E, Solna, Sweden
[3] Univ Ljubljana, Inst Microbiol & Immunol, Fac Med, Ljubljana, Slovenia
[4] Univ Helsinki, Dept Virol, Haartman Inst, Helsinki, Finland
[5] Apodemus AB, Stockholm, Sweden
[6] Uppsala Univ, Dept Med Cell Biol, Uppsala, Sweden
来源
PLOS NEGLECTED TROPICAL DISEASES | 2012年 / 6卷 / 04期
关键词
INFECTIONS; ACCURACY; PUUMALA;
D O I
10.1371/journal.pntd.0001607
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Hantaviruses are endemic throughout the world and hosted by rodents and insectivores. Two human zoonoses, hemorrhagic fever with renal syndrome (HFRS) and hantavirus pulmonary syndrome (HPS), are caused by hantaviruses and case fatality rates have reached 12% for HFRS and 50% for HPS in some outbreaks. Symptomatic hantavirus infections in Europe are summarised as HFRS mainly due to Puumala, Dobrava-Belgrade and Saaremaa virus. While HFRS has an overall low incidence in Europe, the number of cases varies from 100 per year in all Eastern and Southern Europe up to 1,000 per year only in Finland. To assess the quality of hantavirus diagnostics, the European Network for the Diagnostics of 'Imported'' Viral Diseases (ENIVD) organised a first external quality assurance (EQA) in 2002. The purpose of this second EQA study is to collect updated information on the efficiency and accurateness of hantavirus serological methods applied by expert laboratories. A serum panel of 14 samples was sent to 28 participants in Europe of which 27 sent results. Performance in hantavirus diagnosis varied not only on the method used but also on the laboratories and the subclass of antibodies tested. Commercial and in-house assays performed almost equally. Enzyme immunoassays were mainly used but did not show the best performances while immunoblot assays were the less employed and showed overall better performances. IgM antibodies were not detected in 61% of the positive IgM samples and IgM detection was not performed by 7% of the laboratories indicating a risk of overlooking acute infections in patients. Uneven performances using the same method is indicating that there is still a need for improving testing conditions and standardizing protocols.
引用
收藏
页数:6
相关论文
共 50 条
  • [42] An external quality assurance programme for porphyrin
    Thomas, A
    Jones, S
    Davison, L
    CLINICA CHIMICA ACTA, 2005, 355 : S355 - S356
  • [43] Principles of external quality assurance - Reply
    Borchelt, M
    ZEITSCHRIFT FUR GERONTOLOGIE UND GERIATRIE, 1999, 32 (06): : 476 - 478
  • [44] EXTERNAL QUALITY ASSURANCE AND ASSESSMENT IN IMMUNOCYTOCHEMISTRY
    REYNOLDS, GJ
    HISTOPATHOLOGY, 1989, 15 (06) : 627 - 633
  • [45] External Quality Assurance of laboratory analyses
    Pollitt, Rodney J.
    JOURNAL OF INHERITED METABOLIC DISEASE, 2008, 31 (06) : 659 - 660
  • [46] Quality assurance in genetic testing in Europe
    Elles, R
    CLINICA CHIMICA ACTA, 2005, 355 : S15 - S15
  • [47] QUALITY ASSURANCE NETWORK IN CENTRAL-EUROPE - EXTERNAL AUDIT ON OUTPUT CALIBRATION FOR PHOTON BEAMS
    IZEWSKA, J
    NOVOTNY, J
    GWIAZDOWSKA, B
    KINDLOVA, A
    KONTRA, G
    VANDAM, J
    DUTREIX, A
    VANDERSCHUEREN, E
    ACTA ONCOLOGICA, 1995, 34 (06) : 829 - 838
  • [48] External quality assurance programs as a tool for verifying standardization of measurement procedures: Pilot collaboration in Europe
    Perich, C.
    Ricos, C.
    Alvarez, V.
    Biosca, C.
    Boned, B.
    Cava, F.
    Domenech, M. V.
    Fernandez-Calle, P.
    Fernandez-Fernandez, P.
    Garcia-Lario, J. V.
    Minchinela, J.
    Simon, M.
    Jansen, R.
    CLINICA CHIMICA ACTA, 2014, 432 : 82 - 89
  • [49] DOES GOOD PERFORMANCE IN EXTERNAL QUALITY ASSURANCE SURVEYS GUARANTEE CORRECT PATIENT DIAGNOSIS?
    Meijer, Piet
    van Moort, Iris
    Cnossen, Marjon
    van Gammeren, Adriaan
    de Maat, Moniek
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2017, 39 : 74 - 74
  • [50] QUALITY ASSURANCE FOR COMPONENTS IN EUROPE AND THE USA
    CUNY, P
    THOMAS, RW
    ONDE ELECTRIQUE, 1993, 73 (06): : 84 - 89