Second External Quality Assurance Study for the Serological Diagnosis of Hantaviruses in Europe

被引:12
|
作者
Escadafal, Camille [1 ,2 ]
Avsic-Zupanc, Tatjana [3 ]
Vapalahti, Olli [4 ]
Niklasson, Bo [5 ,6 ]
Teichmann, Anette [1 ]
Niedrig, Matthias [1 ]
Donoso-Mantke, Oliver [1 ]
机构
[1] Robert Koch Inst, ZBS 1, Berlin, Germany
[2] European Ctr Dis Prevent & Control ECDC, European Publ Hlth Microbiol Training Programme E, Solna, Sweden
[3] Univ Ljubljana, Inst Microbiol & Immunol, Fac Med, Ljubljana, Slovenia
[4] Univ Helsinki, Dept Virol, Haartman Inst, Helsinki, Finland
[5] Apodemus AB, Stockholm, Sweden
[6] Uppsala Univ, Dept Med Cell Biol, Uppsala, Sweden
来源
PLOS NEGLECTED TROPICAL DISEASES | 2012年 / 6卷 / 04期
关键词
INFECTIONS; ACCURACY; PUUMALA;
D O I
10.1371/journal.pntd.0001607
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Hantaviruses are endemic throughout the world and hosted by rodents and insectivores. Two human zoonoses, hemorrhagic fever with renal syndrome (HFRS) and hantavirus pulmonary syndrome (HPS), are caused by hantaviruses and case fatality rates have reached 12% for HFRS and 50% for HPS in some outbreaks. Symptomatic hantavirus infections in Europe are summarised as HFRS mainly due to Puumala, Dobrava-Belgrade and Saaremaa virus. While HFRS has an overall low incidence in Europe, the number of cases varies from 100 per year in all Eastern and Southern Europe up to 1,000 per year only in Finland. To assess the quality of hantavirus diagnostics, the European Network for the Diagnostics of 'Imported'' Viral Diseases (ENIVD) organised a first external quality assurance (EQA) in 2002. The purpose of this second EQA study is to collect updated information on the efficiency and accurateness of hantavirus serological methods applied by expert laboratories. A serum panel of 14 samples was sent to 28 participants in Europe of which 27 sent results. Performance in hantavirus diagnosis varied not only on the method used but also on the laboratories and the subclass of antibodies tested. Commercial and in-house assays performed almost equally. Enzyme immunoassays were mainly used but did not show the best performances while immunoblot assays were the less employed and showed overall better performances. IgM antibodies were not detected in 61% of the positive IgM samples and IgM detection was not performed by 7% of the laboratories indicating a risk of overlooking acute infections in patients. Uneven performances using the same method is indicating that there is still a need for improving testing conditions and standardizing protocols.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] International external quality control assessment for the serological diagnosis of dengue infections
    Domingo, Cristina
    Alves, Maria Joao
    de Ory, Fernando
    Teichmann, Anette
    Schmitz, Herbert
    Mueller, Rolf
    Niedrig, Matthias
    BMC INFECTIOUS DISEASES, 2015, 15
  • [22] External quality assurance for the laboratory diagnosis of Buruli ulcer disease in Ghana
    Bretzel, G.
    Siegmund, V.
    Nitschke, J.
    Herbinger, K. H.
    Thompson, R.
    Fleischmann, E.
    Fleischer, B.
    Adjei, O.
    TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2006, 11 (11) : 1688 - 1693
  • [23] Statistical approach for optimization of external quality assurance (EQA) studies of molecular and serological viral diagnostics
    Rumer, Leonid
    Domingo, Cristina
    Mantke, Oliver Donoso
    Dobrydneva, Yuliya
    Greiner, Matthias
    Niedrig, Matthias
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (10) : 1589 - 1598
  • [24] EXTERNAL REVIEW IN QUALITY ASSURANCE
    DARNELL, RE
    FITCH, DH
    PHYSICAL THERAPY, 1980, 60 (05): : 559 - 563
  • [25] INTERNAL AND EXTERNAL QUALITY ASSURANCE
    GROTH, TL
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1989, 49 : 87 - 94
  • [26] Quality enhancements and quality assurance of laboratory diagnosis of sexually transmitted infections in Eastern Europe
    Domeika, M.
    Savicheva, A.
    Sokolovskiy, E.
    Ballard, R.
    Unemo, M.
    INTERNATIONAL JOURNAL OF STD & AIDS, 2009, 20 (05) : 365 - 367
  • [27] External quality assurance for immunocytology
    Maxwell, P
    Rhodes, T
    Miller, K
    Anderson, N
    CYTOMETRY, 2002, : 115 - 116
  • [28] Dobrava virus infection:: serological diagnosis and cross-reactions to other hantaviruses
    Sjölander, KB
    Lundkvist, Å
    JOURNAL OF VIROLOGICAL METHODS, 1999, 80 (02) : 137 - 143
  • [29] Quality assurance of radiotherapy in Europe
    Dutreix, A
    Chavaudra, J
    vanderSchueren, E
    EUROPEAN JOURNAL OF CANCER, 1995, 31A : 101 - 101
  • [30] Regional anesthesia and external cephalic version: A quality assurance study
    Patel, R
    Ramanathan, S
    ANESTHESIOLOGY, 1996, 85 (3A) : A876 - A876