An Implantable, Batteryless, and Wireless Capsule With Integrated Impedance and pH Sensors for Gastroesophageal Reflux Monitoring

被引:104
|
作者
Cao, Hung [1 ]
Landge, Vaibhav [1 ]
Tata, Uday [1 ]
Seo, Young-Sik [1 ]
Rao, Smitha [2 ]
Tang, Shou-Jiang [3 ]
Tibbals, H. F. [4 ]
Spechler, Stuart [5 ]
Chiao, J-C [1 ,5 ]
机构
[1] Univ Texas Arlington, Dept Elect Engn, Arlington, TX 76010 USA
[2] Med Worx, Grand Prairie, TX 75050 USA
[3] Univ Mississippi, Med Ctr, Dept Digest Dis, Jackson, MS 39216 USA
[4] Univ Texas Arlington, Dept Mat Sci & Engn, Arligton, TX 76010 USA
[5] Univ Texas SW Med Ctr Dallas, Dept Internal Med, Dallas, TX 75390 USA
基金
美国国家科学基金会;
关键词
Gastroesophageal reflux disease (GERD); impedance sensor; implantable; pH sensor; wireless powering; MULTICHANNEL INTRALUMINAL IMPEDANCE; DATA LINK; ESOPHAGEAL; DISEASE; SYSTEM; DIAGNOSIS; POWER; ACID;
D O I
10.1109/TBME.2012.2214773
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, a device for gastroesophageal reflux disease (GERD) monitoring has been prototyped. The system consists of an implantable, batteryless and wireless transponder with integrated impedance and pH sensors; and a wearable, external reader that wirelessly powers up the transponder and interprets the transponded radio-frequency signals. The transponder implant with the total size of 0.4 cm x0.8 cm x3.8 cm harvests radio frequency energy to operate dual-sensor and load-modulation circuitry. The external reader can store the data in a memory card and/or send it to a base station wirelessly, which is optional in the case of multiple-patient monitoring in a hospital or conducting large-scale freely behaving animal experiments. Tests were carried out to verify the signal transduction reliability in different situations for antenna locations and orientation. In vitro, experiments were conducted in a mannequin model by positioning the sensor capsule inside the wall of a tube mimicking the esophagus. Different liquids with known pH values were flushed through the tube creating reflux episodes and wireless signals were recorded. Live pigs under anesthesia were used for the animal models with the transponder implant attached on the esophageal wall. The reflux episodes were created while the sensor data were recorded wirelessly. The data were compared with those recorded independently by a clinically used wireless pH sensor capsule placed next to our implant transponder. The results showed that our transponder detected every episode in both acid and nonacid nature, while the commercial pH sensor missed events that had similar, repeated pH values, and failed to detect pH values higher than 10. Our batteryless transponder does not require a battery thus allowing longer diagnosis and prognosis periods to monitor drug efficacy, as well as providing accurate assessment of GERD symptoms.
引用
收藏
页码:3131 / 3139
页数:9
相关论文
共 50 条
  • [41] Reason For Inconsistency Between pH Monitoring and Impedance in Detecting Acid Gastroesophageal Reflux: pH-Only Events
    Parlak, Ayse
    Dogruyol, Hasan
    GUNCEL PEDIATRI-JOURNAL OF CURRENT PEDIATRICS, 2021, 19 (02): : 241 - 247
  • [42] Liquid Gastroesophageal Reflux Characterization by Investigating Multichannel Intraluminal Impedance-pH Monitoring Data
    Rasouli, A.
    Rabbani, H.
    Raisi, M.
    Soheilipour, M.
    Adibi, P.
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 4636 - 4639
  • [43] Prognostic Values of Multichannel Intraluminal Impedance and pH Monitoring in Newborns with Symptoms of Gastroesophageal Reflux Disease
    Cresi, Francesco
    Locatelli, Emanuela
    Marinaccio, Cristina
    Grasso, Giulia
    Coscia, Alessandra
    Bertino, Enrico
    JOURNAL OF PEDIATRICS, 2013, 162 (04): : 770 - 775
  • [44] Evaluation of infantile acid and nonacid gastroesophageal reflux using combined pH monitoring and impedance measurement
    Condino, AA
    Sondheimer, J
    Pan, ZX
    Gralla, T
    Perry, T
    O'Connor, JA
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2006, 42 (01): : 16 - 21
  • [45] Evaluation of gastroesophageal reflux in pediatric asthma patients by intraesophageal multichannel impedance-pH monitoring
    不详
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2005, 41 (04): : 499 - 499
  • [46] The role of combined multichannel intraluminal impedance and pH- monitoring in newborn with gastroesophageal reflux disease
    Cresi, Francesco
    Locatelli, Emanuela
    REVIEWS IN HEALTH CARE, 2010, 1 (01) : 35 - 52
  • [47] COMPARISON OF COST-EFFECTIVENESS BETWEEN 96 HOUR WIRELESS BRAVO REFLUX MONITORING AND 24 HOUR PH-IMPEDANCE IN THE DIAGNOSIS OF GASTROESOPHAGEAL REFLUX DISEASE
    Ho, G. N.
    James, T. A.
    Wong, T.
    Jafari, J.
    GUT, 2016, 65 : A174 - A174
  • [48] Parameters on Esophageal pH-Impedance Monitoring That Predict Outcomes of Patients With Gastroesophageal Reflux Disease
    Patel, Amit
    Sayuk, Gregory S.
    Gyawali, C. Prakash
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2015, 13 (05) : 884 - 891
  • [49] Evaluation of infantile acid and nonacid gastroesophageal reflux utilizing combined pH monitoring and impedance measurement
    不详
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2005, 41 (04): : 498 - 499
  • [50] Efficacy of Esophageal Impedance/Ph Monitoring in Patients With Refractory Gastroesophageal Reflux Disease, on and off Therapy
    Sweis, Rami
    Anggiansah, Angela
    Wong, Terry
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2010, 8 (03) : 313 - 313