An Implantable, Batteryless, and Wireless Capsule With Integrated Impedance and pH Sensors for Gastroesophageal Reflux Monitoring

被引:104
|
作者
Cao, Hung [1 ]
Landge, Vaibhav [1 ]
Tata, Uday [1 ]
Seo, Young-Sik [1 ]
Rao, Smitha [2 ]
Tang, Shou-Jiang [3 ]
Tibbals, H. F. [4 ]
Spechler, Stuart [5 ]
Chiao, J-C [1 ,5 ]
机构
[1] Univ Texas Arlington, Dept Elect Engn, Arlington, TX 76010 USA
[2] Med Worx, Grand Prairie, TX 75050 USA
[3] Univ Mississippi, Med Ctr, Dept Digest Dis, Jackson, MS 39216 USA
[4] Univ Texas Arlington, Dept Mat Sci & Engn, Arligton, TX 76010 USA
[5] Univ Texas SW Med Ctr Dallas, Dept Internal Med, Dallas, TX 75390 USA
基金
美国国家科学基金会;
关键词
Gastroesophageal reflux disease (GERD); impedance sensor; implantable; pH sensor; wireless powering; MULTICHANNEL INTRALUMINAL IMPEDANCE; DATA LINK; ESOPHAGEAL; DISEASE; SYSTEM; DIAGNOSIS; POWER; ACID;
D O I
10.1109/TBME.2012.2214773
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, a device for gastroesophageal reflux disease (GERD) monitoring has been prototyped. The system consists of an implantable, batteryless and wireless transponder with integrated impedance and pH sensors; and a wearable, external reader that wirelessly powers up the transponder and interprets the transponded radio-frequency signals. The transponder implant with the total size of 0.4 cm x0.8 cm x3.8 cm harvests radio frequency energy to operate dual-sensor and load-modulation circuitry. The external reader can store the data in a memory card and/or send it to a base station wirelessly, which is optional in the case of multiple-patient monitoring in a hospital or conducting large-scale freely behaving animal experiments. Tests were carried out to verify the signal transduction reliability in different situations for antenna locations and orientation. In vitro, experiments were conducted in a mannequin model by positioning the sensor capsule inside the wall of a tube mimicking the esophagus. Different liquids with known pH values were flushed through the tube creating reflux episodes and wireless signals were recorded. Live pigs under anesthesia were used for the animal models with the transponder implant attached on the esophageal wall. The reflux episodes were created while the sensor data were recorded wirelessly. The data were compared with those recorded independently by a clinically used wireless pH sensor capsule placed next to our implant transponder. The results showed that our transponder detected every episode in both acid and nonacid nature, while the commercial pH sensor missed events that had similar, repeated pH values, and failed to detect pH values higher than 10. Our batteryless transponder does not require a battery thus allowing longer diagnosis and prognosis periods to monitor drug efficacy, as well as providing accurate assessment of GERD symptoms.
引用
收藏
页码:3131 / 3139
页数:9
相关论文
共 50 条
  • [21] Evaluation of gastroesophageal reflux in pediatric patients with asthma using impedance-pH monitoring
    Condino, Adria A.
    Sondheimer, Judith
    Pan, Zhaoxing
    Gralla, Jane
    Perry, Darryl
    O'Connor, Judith A.
    JOURNAL OF PEDIATRICS, 2006, 149 (02): : 216 - 219
  • [22] Evaluation of Gastroesophageal Reflux in Children Born With Esophageal Atresia Using pH and Impedance Monitoring
    Vergouwe, Floor W. T.
    van Wijk, Michiel P.
    Spaander, Manon C. W.
    Bruno, Marco J.
    Wijnen, Rene M. H.
    Schnater, Johannes M.
    IJsselstijn, Hanneke
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2019, 69 (05): : 515 - 522
  • [23] Weakly acidic gastroesophageal reflux: Further characterization with impedance-double pH monitoring
    Lazarescu, Adriana
    Bisschops, Raf
    Demedts, Ingrid
    Tack, Jan F.
    Tytgat, Guido N.
    Sifrim, Daniel
    GASTROENTEROLOGY, 2008, 134 (04) : A594 - A595
  • [24] Evaluation of gastroesophageal reflux in pediatric patients using multichannel intraluminal impedance and pH monitoring
    Shim, Jeongok
    Park, Jisook
    Shin, Jeeyoun
    Lee, Kunsong
    Lee, Junghwa
    Han, Jaejoon
    Yang, Hyeran
    Chang, Juyoung
    Ko, Jaesung
    Seo, Jeongkee
    NEUROGASTROENTEROLOGY AND MOTILITY, 2007, 19 : 33 - 33
  • [25] Esophageal pH monitoring and impedance measurement: A comparison of two diagnostic tests for gastroesophageal reflux
    Wenzl, TG
    Moroder, C
    Trachterna, M
    Thomson, M
    Silny, J
    Heimann, G
    Skopnik, H
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2002, 34 (05): : 519 - 523
  • [26] GASTROESOPHAGEAL SCINTIGRAPHY AND PH MONITORING IN ASTHMATIC ADULTS WITH GASTROESOPHAGEAL REFLUX
    VEYRAC, M
    BORIES, P
    COLLET, H
    PARELON, G
    FAUROUX, P
    GODARD, P
    MICHEL, H
    GASTROENTEROLOGIE CLINIQUE ET BIOLOGIQUE, 1986, 10 (05): : 400 - 404
  • [27] Comparison of multichannel intraluminal impedance-pH monitoring and reflux scintigraphy in pediatric patients with suspected gastroesophageal reflux
    Kizilkan, Nuray Uslu
    Bozkurt, Murat Fani
    Temizel, Inci Nur Saltik
    Demir, Hulya
    Yuce, Aysel
    Caner, Biray
    Ozen, Hasan
    WORLD JOURNAL OF GASTROENTEROLOGY, 2016, 22 (43) : 9595 - 9603
  • [28] Reflux profile of Chinese gastroesophageal reflux disease patients with combined multichannel intraluminal impedance-pH monitoring
    Xiao, Ying L.
    Lin, Jin K.
    Cheung, Ting K.
    Wong, Nina Y. H.
    Hung, Ivan F. N.
    Wong, Benjamin C. Y.
    Peng, Sui
    Wang, An J.
    Chen, Min H.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2009, 24 (06) : 1113 - 1118
  • [29] Efficacy and Safety of the Wireless Capsule pH Monitoring System in the Evaluation of Gastroesophageal Reflux Disease (GERD): Results From a Multiracial Asian Cohort
    Ang, Daphne
    Ang, Tiing Leong
    Lim, Kieron B.
    Teo, Eng Kiong
    Fock, Kwong Ming
    GASTROENTEROLOGY, 2010, 138 (05) : S494 - S494
  • [30] GASTROESOPHAGEAL REFLUX DISEASE, PH MONITORING, AND TREATMENT
    FRASER, R
    VERDU, E
    ARMSTRONG, D
    BLUM, A
    CURRENT OPINION IN GASTROENTEROLOGY, 1992, 8 (04) : 562 - 572