An Implantable, Batteryless, and Wireless Capsule With Integrated Impedance and pH Sensors for Gastroesophageal Reflux Monitoring

被引:104
|
作者
Cao, Hung [1 ]
Landge, Vaibhav [1 ]
Tata, Uday [1 ]
Seo, Young-Sik [1 ]
Rao, Smitha [2 ]
Tang, Shou-Jiang [3 ]
Tibbals, H. F. [4 ]
Spechler, Stuart [5 ]
Chiao, J-C [1 ,5 ]
机构
[1] Univ Texas Arlington, Dept Elect Engn, Arlington, TX 76010 USA
[2] Med Worx, Grand Prairie, TX 75050 USA
[3] Univ Mississippi, Med Ctr, Dept Digest Dis, Jackson, MS 39216 USA
[4] Univ Texas Arlington, Dept Mat Sci & Engn, Arligton, TX 76010 USA
[5] Univ Texas SW Med Ctr Dallas, Dept Internal Med, Dallas, TX 75390 USA
基金
美国国家科学基金会;
关键词
Gastroesophageal reflux disease (GERD); impedance sensor; implantable; pH sensor; wireless powering; MULTICHANNEL INTRALUMINAL IMPEDANCE; DATA LINK; ESOPHAGEAL; DISEASE; SYSTEM; DIAGNOSIS; POWER; ACID;
D O I
10.1109/TBME.2012.2214773
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, a device for gastroesophageal reflux disease (GERD) monitoring has been prototyped. The system consists of an implantable, batteryless and wireless transponder with integrated impedance and pH sensors; and a wearable, external reader that wirelessly powers up the transponder and interprets the transponded radio-frequency signals. The transponder implant with the total size of 0.4 cm x0.8 cm x3.8 cm harvests radio frequency energy to operate dual-sensor and load-modulation circuitry. The external reader can store the data in a memory card and/or send it to a base station wirelessly, which is optional in the case of multiple-patient monitoring in a hospital or conducting large-scale freely behaving animal experiments. Tests were carried out to verify the signal transduction reliability in different situations for antenna locations and orientation. In vitro, experiments were conducted in a mannequin model by positioning the sensor capsule inside the wall of a tube mimicking the esophagus. Different liquids with known pH values were flushed through the tube creating reflux episodes and wireless signals were recorded. Live pigs under anesthesia were used for the animal models with the transponder implant attached on the esophageal wall. The reflux episodes were created while the sensor data were recorded wirelessly. The data were compared with those recorded independently by a clinically used wireless pH sensor capsule placed next to our implant transponder. The results showed that our transponder detected every episode in both acid and nonacid nature, while the commercial pH sensor missed events that had similar, repeated pH values, and failed to detect pH values higher than 10. Our batteryless transponder does not require a battery thus allowing longer diagnosis and prognosis periods to monitor drug efficacy, as well as providing accurate assessment of GERD symptoms.
引用
收藏
页码:3131 / 3139
页数:9
相关论文
共 50 条
  • [1] An Implantable, Batteryless and Wireless Capsule with Integrated Impedance and pH Sensors for Detecting the Reflux of Acidic and Non-Acidic Materials
    Hsu, Lun-Chen
    Tang, Shou-jiang
    Huang, Wen-Ding
    Hogg, Deborah C.
    Tibbals, Harry F.
    Spechler, Stuart J.
    Chiao, Jung-Chih
    GASTROENTEROLOGY, 2009, 136 (05) : A649 - A649
  • [2] An Implantable Batteryless Wireless Impedance Sensor for Gastroesophageal Reflux Diagnosis
    Ativanichayaphong, Thermpon
    Tang, Shou-Jian
    Hsu, Lun-Chen
    Huang, Wen-Ding
    Seo, Young-Sik
    Tibbals, H. F.
    Spechler, Stuart
    Chiao, J-C.
    2010 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST (MTT), 2010, : 608 - 611
  • [3] An implantable, wireless and batteryless impedance sensor capsule for detecting acidic and non-acidic reflux
    Ativanichayaphong, Thermpon
    Tang, Shou Jiang
    Wang, Jianqun
    Huang, Wen-Ding
    Tibbals, Harry F.
    Spechler, Stuart J.
    Chiao, Jung-Chih
    GASTROENTEROLOGY, 2008, 134 (04) : A63 - A63
  • [4] Batteryless implantable dual-sensor capsule for esophageal reflux monitoring
    Cao, Hung
    Rao, Smitha
    Tang, Shou-jiang
    Tibbals, Harry F.
    Spechler, Stuart
    Chiao, J. -C.
    GASTROINTESTINAL ENDOSCOPY, 2013, 77 (04) : 649 - 653
  • [5] Nocturnal Gastroesophageal Reflux Revisited by Impedance-pH Monitoring
    Fornari, Fernando
    Blondeau, Kathleen
    Mertens, Veerle
    Tack, Jan
    Sifrim, Daniel
    JOURNAL OF NEUROGASTROENTEROLOGY AND MOTILITY, 2011, 17 (02) : 148 - 157
  • [6] Comparison of Gastroesophageal Acid Reflux Detection Rates in Symptomatic Patients Between Impedance pH Test and Ambulatory Capsule pH Monitoring
    Hassan, Seemeen
    Ahmed, Zaheer
    Chhabra, Rajiv
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2020, 115 : S176 - S177
  • [7] Extended Wireless pH Monitoring Significantly Increases Gastroesophageal Reflux Disease Diagnoses in Patients With a Normal pH Impedance Study
    Zeki, Sebastian S.
    Miah, Ismail
    Visaggi, Pierfrancesco
    Wolak, Anna
    deSilva, Minerva
    Dunn, Jason M.
    Davies, Andrew
    Gossage, James
    Botha, Abrie
    Sui, Guiping
    Jafari, Jafar
    Wong, Terry
    JOURNAL OF NEUROGASTROENTEROLOGY AND MOTILITY, 2023, 29 (03) : 335 - 342
  • [8] Gastroesophageal reflux and atypical symptoms: The role of impedance-pH monitoring
    Fornari, Fernando
    Sifrim, Daniel
    DIGESTION, 2007, 76 (3-4) : 221 - 222
  • [9] Nocturnal gastroesophageal reflux (Nger) revisited with impedance-pH monitoring
    Fornari, Fernando
    Blondeau, Kathleen
    Tack, Jan
    Sifrim, Daniel
    GASTROENTEROLOGY, 2007, 132 (04) : A280 - A280
  • [10] An implantable wireless impedance sensor capable of distinguishing air, water and acid in gastroesophageal reflux
    Ativanichayaphong, Thermpon
    Huang, Wen-Ding
    Wang, Jianqun
    Rao, Smitha
    Tibbals, Harry
    Tang, Shou-Jiang
    Spechler, Stuart J.
    Stephanou, Harry
    Chiao, Jung-Chih
    GASTROINTESTINAL ENDOSCOPY, 2007, 65 (05) : AB332 - AB332