Revision of partial knee to total knee arthroplasty with use of patient-specific instruments results in acceptable femoral rotation

被引:5
|
作者
Schotanus, Martijn G. M. [1 ]
Thijs, Elke [1 ]
Boonen, B. [1 ]
Kerens, B. [2 ]
Jong, B. [3 ]
Kort, Nanne P. [1 ]
机构
[1] Zuyderland Med Ctr, Dept Orthoped Surg & Traumatol, Dr H vd Hoffpl 1, NL-6162 AG Sittard Geleen, Netherlands
[2] AZ St Maarten, Mechelen, Belgium
[3] Zuyderland Med Ctr, Dept Radiol, Sittard Geleen, Netherlands
关键词
Patient-specific instruments; PSI; Revision; Partial knee arthroplasty; PKA; Unicompartmental knee arthroplasty; UKA; Total knee arthroplasty; TKA; CT-based; Outliers; Planning; Alignment; ALIGNMENT; REPLACEMENT; METAANALYSIS; CT; COMPONENTS; OUTCOMES; LEVEL; MRI;
D O I
10.1007/s00167-017-4674-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Patient-specific instruments (PSI) were initially developed for the alignment of both total knee- (TKA) and partial knee arthroplasty (PKA). We hypothesize that CT-based PSI for PKA-to-TKA revision surgery can restore biomechanical limb alignment and prosthetic component positioning in vivo as calculated pre-operatively, resulting in a limited percentages of outliers. An imaging analysis was performed using CT-based 3D measurement methods based on a pre- and post-revision CT scan. Imaging data were gathered on 10 patients who were operated for PKA-to-TKA revision with the use of PSI based on CT imaging. The planned femur and tibia component position in vivo were compared with the pre-revision planned component position. Outliers were defined as deviations > 3.0A degrees from pre-revision planned position for the individual implant components. Adjustments (e.g. resection level and implant size) during surgery were recorded. The HKA axis was restored accurately in all patients with a mean post-operative HKA axis of 178.1A degrees (1.4A degrees). Five femoral (2 varus, 2 internal rotation and 1 extension) and 14 tibial guides (2 varus, 6 anterior slope, 3 internal rotation and 3 external rotation) on a total of 60 outcome measures were identified as outliers. During surgery, an intraoperative tibial resection of 2 mm extra was performed in three patients. In 80 and 70% for, respectively, the femur and tibia, the surgeon-planned size was implanted during surgery. All patient-specific guides fitted well in all patients. No intraoperative or post-operative complications related to surgery were registered. This study introduced a unique new concept regarding PSI, PKA-to-TKA revision surgery. Based on the results, we were unable to fully confirm our hypothesis. PSI as a "new" tool for PKA-to-TKA revision surgery appears to be an accurate tool for the alignment of the TKA femur component. The tibial guide seems more susceptible to errors, resulting in a substantial percentage of outliers. Prospective cohort study, Level II.
引用
收藏
页码:1656 / 1661
页数:6
相关论文
共 50 条
  • [41] Assessing the accuracy of patient-specific guides for total knee arthroplasty
    Jong-Keun Seon
    Hyeong-Won Park
    Seung-Hyun Yoo
    Eun-Kyoo Song
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 3678 - 3683
  • [42] Reliability of Templating with Patient-Specific Instrumentation in Total Knee Arthroplasty
    Issa, Kimona
    Rifai, Aiman
    McGrath, Mike S.
    Callaghan, John J.
    Wright, Craig
    Malkani, Arthur L.
    Mont, Michael A.
    McInerney, Vincent K.
    JOURNAL OF KNEE SURGERY, 2013, 26 (06) : 429 - 433
  • [43] Kinematically Aligned Total Knee Arthroplasty with Patient-Specific Instrument
    Kim, Kwang-kyoun
    Howell, Stephen M.
    Won, Ye-yeon
    YONSEI MEDICAL JOURNAL, 2020, 61 (03) : 201 - 209
  • [44] Patient-Specific Instrumentation in Total Knee Arthroplasty: What Is the Evidence?
    Szczech, Bartlomiej
    McDermott, James D.
    Issa, Kimona
    Rifai, Aiman
    Festa, Anthony
    Matarese, William A.
    McInerney, Vincent K.
    JOURNAL OF KNEE SURGERY, 2016, 29 (04) : 341 - 345
  • [45] Laboratory validation of patient-specific templating for total knee arthroplasty
    Hafez, Mahmoud A.
    Jansen, Arne
    Portheine, Frank
    Jaramaz, Branislav
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [46] Assessing the accuracy of patient-specific guides for total knee arthroplasty
    Seon, Jong-Keun
    Park, Hyeong-Won
    Yoo, Seung-Hyun
    Song, Eun-Kyoo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (11) : 3678 - 3683
  • [47] Total Knee Arthroplasty: Validating The Benefits Of Patient-Specific Instrumentation
    Moore, S.
    Linton, K. N.
    Martin, P.
    Headon, R. J.
    Bennett, D.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2018, 187 : S74 - S75
  • [48] Novel patient-specific navigational template for total knee arthroplasty
    Gan, Yudong
    Xu, Dachuan
    Lu, Sheng
    Ding, Jing
    COMPUTER AIDED SURGERY, 2011, 16 (06) : 288 - 297
  • [49] Patient-specific instrumentation makes sense in total knee arthroplasty
    Leon-Munoz, Vicente J.
    Lopez-Lopez, Mirian
    Santonja-Medina, Fernando
    EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (06) : 489 - 497
  • [50] A prospective study on outcome of patient-specific cones in revision knee arthroplasty
    Cherny, Alexander A.
    Kovalenko, Anton N.
    Kulyaba, Taras A.
    Kornilov, Nikolai N.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (12) : 2277 - 2286