Revision of partial knee to total knee arthroplasty with use of patient-specific instruments results in acceptable femoral rotation

被引:5
|
作者
Schotanus, Martijn G. M. [1 ]
Thijs, Elke [1 ]
Boonen, B. [1 ]
Kerens, B. [2 ]
Jong, B. [3 ]
Kort, Nanne P. [1 ]
机构
[1] Zuyderland Med Ctr, Dept Orthoped Surg & Traumatol, Dr H vd Hoffpl 1, NL-6162 AG Sittard Geleen, Netherlands
[2] AZ St Maarten, Mechelen, Belgium
[3] Zuyderland Med Ctr, Dept Radiol, Sittard Geleen, Netherlands
关键词
Patient-specific instruments; PSI; Revision; Partial knee arthroplasty; PKA; Unicompartmental knee arthroplasty; UKA; Total knee arthroplasty; TKA; CT-based; Outliers; Planning; Alignment; ALIGNMENT; REPLACEMENT; METAANALYSIS; CT; COMPONENTS; OUTCOMES; LEVEL; MRI;
D O I
10.1007/s00167-017-4674-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Patient-specific instruments (PSI) were initially developed for the alignment of both total knee- (TKA) and partial knee arthroplasty (PKA). We hypothesize that CT-based PSI for PKA-to-TKA revision surgery can restore biomechanical limb alignment and prosthetic component positioning in vivo as calculated pre-operatively, resulting in a limited percentages of outliers. An imaging analysis was performed using CT-based 3D measurement methods based on a pre- and post-revision CT scan. Imaging data were gathered on 10 patients who were operated for PKA-to-TKA revision with the use of PSI based on CT imaging. The planned femur and tibia component position in vivo were compared with the pre-revision planned component position. Outliers were defined as deviations > 3.0A degrees from pre-revision planned position for the individual implant components. Adjustments (e.g. resection level and implant size) during surgery were recorded. The HKA axis was restored accurately in all patients with a mean post-operative HKA axis of 178.1A degrees (1.4A degrees). Five femoral (2 varus, 2 internal rotation and 1 extension) and 14 tibial guides (2 varus, 6 anterior slope, 3 internal rotation and 3 external rotation) on a total of 60 outcome measures were identified as outliers. During surgery, an intraoperative tibial resection of 2 mm extra was performed in three patients. In 80 and 70% for, respectively, the femur and tibia, the surgeon-planned size was implanted during surgery. All patient-specific guides fitted well in all patients. No intraoperative or post-operative complications related to surgery were registered. This study introduced a unique new concept regarding PSI, PKA-to-TKA revision surgery. Based on the results, we were unable to fully confirm our hypothesis. PSI as a "new" tool for PKA-to-TKA revision surgery appears to be an accurate tool for the alignment of the TKA femur component. The tibial guide seems more susceptible to errors, resulting in a substantial percentage of outliers. Prospective cohort study, Level II.
引用
收藏
页码:1656 / 1661
页数:6
相关论文
共 50 条
  • [21] EARLY RADIOLOGICAL RESULTS AFTER TOTAL KNEE ARTHROPLASTY USING PATIENT-SPECIFIC INSTRUMENTS AND IMPLANTS (ITOTAL™)
    Steinert, A. F.
    Kamawal, Y.
    Arnholdt, J.
    Holzapfel, B.
    Ripp, A.
    Rudert, M.
    OSTEOARTHRITIS AND CARTILAGE, 2016, 24 : S518 - S518
  • [22] Comment on Conteduca et al.: Patient-specific instruments in total knee arthroplasty
    Vaishya, Raju
    Vijay, Vipul
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (05) : 1123 - 1124
  • [23] Evolution of total knee arthroplasty. From robotics and navigation to patient-specific instruments
    Haaker, R.
    ORTHOPADE, 2016, 45 (04): : 280 - +
  • [24] Frontal plane alignment after total knee arthroplasty using patient-specific instruments
    Daniilidis, Kiriakos
    Tibesku, Carsten O.
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (01) : 45 - 50
  • [25] Patient-Specific Instrumentation in Total Knee Arthroplasty: A Review
    Nam, Denis
    McArthur, Benjamin A.
    Cross, Michael B.
    Pearle, Andrew D.
    Mayman, David J.
    Haas, Steven B.
    JOURNAL OF KNEE SURGERY, 2012, 25 (03) : 213 - 219
  • [26] Comment on Conteduca et al.: Patient-specific instruments in total knee arthroplasty
    Raju Vaishya
    Vipul Vijay
    International Orthopaedics, 2014, 38 : 1123 - 1124
  • [27] Frontal plane alignment after total knee arthroplasty using patient-specific instruments
    Kiriakos Daniilidis
    Carsten O. Tibesku
    International Orthopaedics, 2013, 37 : 45 - 50
  • [28] Use of distal femoral allografts in revision total knee arthroplasty
    Paprosky, WG
    CURRENT CONCEPTS IN PRIMARY AND REVISION TOTAL KNEE ARTHROPLASTY, 1996, : 217 - 226
  • [29] Total knee arthroplasty with the use of patient specific instruments. The VISIONAIRE system
    Tibesku, C. O.
    ORTHOPADE, 2016, 45 (04): : 286 - 293
  • [30] The use of patient-specific instruments does not reduce blood loss during minimally invasive total knee arthroplasty?
    Thienpont, Emmanuel
    Grosu, Irina
    Paternostre, Frederic
    Schwab, Pierre-Emmanuel
    Yombi, Jean Cyr
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (07) : 2055 - 2060