Fail-safe optimization of viscous dampers for seismic retrofitting

被引:13
|
作者
Pollini, Nicolo [1 ]
机构
[1] Tech Univ Denmark, Dept Wind Energy, DK-4000 Roskilde, Denmark
来源
关键词
adjoint sensitivity analysis; fail-safe design; passive control; seismic retrofitting; transient optimization; viscous dampers; MODAL-ANALYSIS PROCEDURES; EQUIVALENT LATERAL FORCE; OPTIMAL-DESIGN; TOPOLOGY OPTIMIZATION; VISCOELASTIC DAMPERS; FRAMED STRUCTURES; OPTIMAL PLACEMENT; BUILDINGS; PROTECTION; 2000-NEHRP-PROVISIONS;
D O I
10.1002/eqe.3319
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a new optimization approach for designing minimum-cost fail-safe distributions of fluid viscous dampers for seismic retrofitting. Failure is modeled as either complete damage of the dampers or partial degradation of the dampers' properties. In general, this leads to optimization problems with large number of constraints. This may result in high computational costs if all the constraints are simultaneously considered during the optimization analysis. Thus, to reduce the computational effort, the use of a working-set optimization algorithm is proposed in this paper. The main idea is to solve a sequence of relaxed optimization subproblems with a small subset of all constraints. The algorithm terminates once a solution of a subproblem is found that satisfies all the constraints of the problem. The retrofitting cost is minimized with constraints on the interstory drifts at the peripheries of frame structures. The structures considered are subjected to a realistic ensemble of ground motions, and their response is evaluated with time-history analyses. The transient optimization problem is efficiently solved with a gradient-based sequential linear programming algorithm. The gradients of the response functions are calculated with a consistent adjoint sensitivity analysis procedure. Promising results attained for 3-D irregular frames are presented and discussed. The numerical results highlight the fact that the optimized layout and size of the dampers can change significantly even for moderate levels of damage.
引用
收藏
页码:1599 / 1618
页数:20
相关论文
共 50 条
  • [31] Adaptive topology optimization of fail-safe truss structures
    Helen E. Fairclough
    Linwei He
    Tekle B. Asfaha
    Sam Rigby
    Structural and Multidisciplinary Optimization, 2023, 66
  • [32] Multiscale fail-safe topology optimization for lattice structures
    Huang, Huili
    Ding, Wei
    Jia, Huanfei
    Zuo, Wenjie
    Cheng, Fei
    Thin-Walled Structures, 2025, 206
  • [33] Think fail-safe
    Hutheesing, N
    FORBES, 1998, 162 (01): : 164 - +
  • [34] FAILURE OF FAIL-SAFE
    GIBBS, E
    TRANS-ACTION, 1969, 6 (05): : 63 - 64
  • [35] FAIL-SAFE SYSTEM
    不详
    INSTRUMENTATION TECHNOLOGY, 1975, 22 (10): : 55 - 55
  • [36] FAIL-SAFE DISKS
    BARDEN, W
    POPULAR COMPUTING, 1982, 1 (08): : 134 - &
  • [37] FAIL-SAFE DESIGN
    KLETZ, TA
    CHEMICAL ENGINEERING, 1984, 91 (12) : 5 - 5
  • [38] FAIL-SAFE CAPACITORS
    LLOYD, G
    ELECTRONIC ENGINEERING, 1984, 56 (690): : 71 - 72
  • [39] Seismic Retrofitting of an Existing Steel Railway Bridge by Fluid Viscous Dampers
    Gangopadhyay A.
    Ghosh A.D.
    Gangopadhyay, Avijit (gangulyavi@gmail.com), 2016, Springer (97) : 291 - 297
  • [40] Multi-objective loss-based optimization of viscous dampers for seismic retrofitting of irregular structures
    Puthanpurayil, Arun M.
    Lavan, Oren
    Dhakal, Rajesh P.
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2020, 129 (129)