Accuracy of dental implant surgery using dynamic navigation and robotic systems: An in vitro study

被引:64
|
作者
Tao, Baoxin [1 ]
Feng, Yuan [2 ]
Fan, Xingqi [3 ]
Zhuang, Minjie [1 ]
Chen, Xiaojun [3 ]
Wang, Feng [4 ]
Wu, Yiqun [1 ]
机构
[1] Shanghai Jiao Tong Univ, Coll Stomatol,Sch Med,Shanghai Key Lab Stomatol,S, Chinese Acad Med Sci,Res Unit Oral & Maxillofacia, Natl Ctr Stomatol,Natl Clin Res Ctr Oral Dis,Dept, 280 Mohe Rd, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Mech Engn, Dongchuan Rd 800, Shanghai 200240, Peoples R China
[3] Shanghai Jiao Tong Univ, Inst Biomed Mfg & Life Qual Engn, Sch Mech Engn, State Key Lab Mech Syst & Vibrat, Room 805,Dongchuan Rd 800, Shanghai 200240, Peoples R China
[4] Shanghai Jiao Tong Univ, Dept Oral Implantol,Sch Med,Res Unit Oral & Maxil, Chinese Acad Med Sci,Shanghai Key Lab Stomatol,Sh, Coll Stomatol,Natl Ctr Stomatol,Natl Clin Res Ctr, 639 Zhizaoju Rd, Shanghai, Peoples R China
关键词
Accuracy; Computer-assisted surgery; Robot-assisted surgery; Phantom study; CURRENT STATE; PLACEMENT; METAANALYSIS; GUIDE;
D O I
10.1016/j.jdent.2022.104170
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare the accuracy of dental implant placement using a dynamic navigation and a robotic system. Methods: Eighty three-dimensional (3D) printed phantoms, including edentulous and partially edentulous jaws, were assigned to two groups: a dynamic navigation system (Beidou-SNS) group and a robotic system (Hybrid Robotic System for Dental Implant Surgery, HRS-DIS) group. The entry, exit and angle deviations of the implants in 3D world were measured after pre-operative plans and postoperative cone-beam computed tomography (CBCT) fusion. A linear mixed model with a random intercept was applied, and a p value <.05 was considered statistically significant. Results: A total of 480 implants were placed in 80 phantoms. The comparison deviation of the dynamic navigation system and robotic system groups showed a mean (+/- SD) entry deviation of 0.96 +/- 0.57 mm vs. 0.83 +/- 0.55 mm (p=0.04), a mean exit deviation of 1.06 +/- 0.59 mm vs. 0.91 +/- 0.56 mm (p=0.04), and a mean angle deviation of 2.41 +/- 1.42 degrees vs. 1 +/- 0.48 degrees (p<0.00). Conclusions: The implant positioning accuracy of the robotic system was superior to that of the dynamic navigation system, suggesting that this prototype robotic system (HRS-DIS) could be a promising tool in dental implant surgery.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Accuracy of different registration areas using active and passive dynamic navigation systems in dental implant surgery: An in vitro study
    Wu, Bin-Zhang
    Ma, Fei-Fei
    Yan, Xiao-Yan
    Sun, Feng
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 888 - 897
  • [2] Accuracy of dental implant placement using different dynamic navigation and robotic systems: an in vitro study (vol 7, 182, 2024)
    Xu, Zonghe
    Zhou, Lin
    Han, Bin
    Wu, Shuang
    Xiao, Yanjun
    Zhang, Sihui
    Chen, Jiang
    Guo, Jianbin
    Wu, Dong
    NPJ DIGITAL MEDICINE, 2024, 7 (01):
  • [3] Comparison the accuracy of a novel implant robot surgery and dynamic navigation system in dental implant surgery: an in vitro pilot study
    Chen, Jianping
    Bai, Xiaolei
    Ding, Yude
    Shen, Liheng
    Sun, Xin
    Cao, Ruijue
    Yang, Fan
    Wang, Linhong
    BMC ORAL HEALTH, 2023, 23 (01)
  • [4] Comparison the accuracy of a novel implant robot surgery and dynamic navigation system in dental implant surgery: an in vitro pilot study
    Jianping Chen
    Xiaolei Bai
    Yude Ding
    Liheng Shen
    Xin Sun
    Ruijue Cao
    Fan Yang
    Linhong Wang
    BMC Oral Health, 23
  • [5] The accuracy and learning curve of active and passive dynamic navigation-guided dental implant surgery: An in vitro study
    Wang, Xiao-yu
    Liu, Lin
    Guan, Miao-sheng
    Liu, Qian
    Zhao, Tong
    Li, Hong-bo
    JOURNAL OF DENTISTRY, 2022, 124
  • [6] The accuracy and learning curve of active and passive dynamic navigation-guided dental implant surgery: An in vitro study
    Wang, Xiao-Yu
    Liu, Lin
    Guan, Miao-Sheng
    Liu, Qian
    Zhao, Tong
    Li, Hong-Bo
    JOURNAL OF DENTISTRY, 2022, 124
  • [7] Comparison of the accuracy of dental implant placement using dynamic and augmented reality-based dynamic navigation: An in vitro study
    Tao, Baoxin
    Fan, Xingqi
    Wang, Feng
    Chen, Xiaojun
    Shen, Yihan
    Wu, Yiqun
    JOURNAL OF DENTAL SCIENCES, 2024, 19 (01) : 196 - 202
  • [8] Accuracy of Zygomatic Implant Placement Using Task-Autonomous Robotic System or Dynamic Navigation: An In Vitro Study
    Chen, Jinyan
    Tao, Baoxin
    Yu, Xinbo
    Wu, Yiqun
    Wang, Feng
    CLINICAL ORAL IMPLANTS RESEARCH, 2025, 36 (02) : 178 - 190
  • [9] Dynamic Navigation for Dental Implant Surgery
    Panchal, Neeraj
    Mahmood, Laith
    Retana, Armando
    Emery, Robert, III
    ORAL AND MAXILLOFACIAL SURGERY CLINICS OF NORTH AMERICA, 2019, 31 (04) : 539 - +
  • [10] Accuracy of an autonomous dental implant robotic system in dental implant surgery
    Wu, Yu
    Zou, Shiqi
    Lv, Pin
    Wang, Xiao
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (03): : 764 - 770