Direct comparison between a programmable and a conventional Josephson voltage standard at the level of 10V

被引:22
|
作者
Djordjevic, S. [1 ]
Seron, O. [1 ]
Solve, S. [2 ]
Chayramy, R. [2 ]
机构
[1] Lab Natl Metrol & Essais LNE, F-78197 Trappes, France
[2] Bur Int Poids & Mesures, F-92312 Sevres, France
关键词
D O I
10.1088/0026-1394/45/4/008
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A Josephson voltage standard (JVS) from the BIPM, incorporating a PTB 10V programmable array, has been compared with a JVS from the LNE, operating with a conventional hysteretic array. The metrological characteristics of both JVSs were carefully studied. We report on the experiments performed for this comparison and on the uncertainty components. The final comparison result is (U(PJVS)-U(JVS))/U(JVS) = -3.2 x 10(-11) with a relative total combined standard uncertainty of 6.1 x 10(-11) (k = 1).
引用
收藏
页码:429 / 435
页数:7
相关论文
共 50 条
  • [31] Calibration System for Zener Voltage Standards Using a 10 V Programmable Josephson Voltage Standard at NMIJ
    Maruyama, Michitaka
    Iwasa, Akio
    Yamamori, Hirotake
    Chen, Shih-Fang
    Urano, Chiharu
    Kaneko, Nobu-hisa
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (06) : 1606 - 1612
  • [32] A 10-V JOSEPHSON VOLTAGE STANDARD
    HAMILTON, CA
    LLOYD, FL
    CHIEH, K
    GOEKE, WC
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1989, 38 (02) : 314 - 316
  • [33] Automated direct comparison of two cryocooled 10 volt programmable Josephson voltage standards
    Rufenacht, Alain
    Tang, Yi-hua
    Solve, Stephane
    Fox, Anna E.
    Dresselhaus, Paul D.
    Burroughs, Charles J.
    Schwall, Robert E.
    Chayramy, Regis
    Benz, Samuel P.
    METROLOGIA, 2018, 55 (04) : 585 - 596
  • [34] 10 Volt Automated Direct Comparison of Two Cryocooled Programmable Josephson Voltage Standards
    Rufenacht, Alain
    Tang, Yi-hua
    Fox, Anna E.
    Dresselhaus, Paul D.
    Burroughs, Charles J.
    Schwall, Robert E.
    Benz, Samuel P.
    2016 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2016), 2016,
  • [35] DC Comparison of a Programmable Josephson Voltage Standard and a Josephson Arbitrary Waveform Synthesizer
    Rufenacht, Alain
    Flowers-Jacobs, Nathan E.
    Fox, Anna E.
    Waltman, Steven B.
    Schwall, Robert E.
    Burroughs, Charles J.
    Dresselhaus, Paul D.
    Benz, Samuel P.
    2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [36] Direct DC 10 V comparison between two programmable Josephson voltage standards made of niobium nitride (NbN)-based and niobium (Nb)-based Josephson junctions
    Solve, S.
    Chayramy, R.
    Maruyama, M.
    Urano, C.
    Kaneko, N-H
    Rufenacht, A.
    METROLOGIA, 2018, 55 (02) : 302 - 313
  • [37] High precision comparison between a programmable and a pulse-driven Josephson voltage standard
    Jeanneret, Blaise
    Ruefenacht, Alain
    Overney, Frederic
    van den Brom, Helko
    Houtzager, Ernest
    METROLOGIA, 2011, 48 (05) : 311 - 316
  • [38] A compact comparison standard based on the Josephson effect with an output voltage of 10 V
    A. S. Katkov
    V. E. Lovtsyus
    Measurement Techniques, 2011, 54 : 801 - 807
  • [39] Operation of a 10-V programmable Josephson voltage standard system with a 10-K compact cryocooler
    Yamada, T.
    Murayama, Y.
    Yamamori, H.
    Sasaki, H.
    Shoji, A.
    Iwasa, A.
    Nishinaka, H.
    Nakamura, Y.
    2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 378 - +
  • [40] A COMPACT COMPARISON STANDARD BASED ON THE JOSEPHSON EFFECT WITH AN OUTPUT VOLTAGE OF 10 V
    Katkov, A. S.
    Lovtsyus, V. E.
    MEASUREMENT TECHNIQUES, 2011, 54 (07) : 801 - 807