Forward cardiac output measurement with first-pass technique using 99mTc-labeled myocardial perfusion imaging agents

被引:0
|
作者
Taki, J
Muramori, A
Kinuya, S
Nakajima, K
Matsunari, I
Miyazaki, Y
Murata, Y
Tonami, N
机构
[1] Kanazawa Univ, Sch Med, Dept Nucl Med, Kanazawa, Ishikawa 9208640, Japan
[2] Noto Gen Hosp, Dept Radiol, Div Nucl Med, Nanao, Japan
[3] Noto Gen Hosp, Dept Internal Med, Div Cardiol, Nanao, Japan
关键词
forward cardiac output; Tc-99m-labeled myocardial agents; tetrofosmin; radionuclide angiography;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to develop and validate a new first-pass method for the measurement of forward cardiac output (CO) using Tc-99m-labeled myocardial perfusion imaging agents. Methods: In protocol 1, to test the new method for measuring CO, the conventional method and the new method for CO measurement were performed in 1 d in 57 patients (32 men, 25 women; age 68 +/- 11 y). In the conventional method, radionuclide angiography (1 frame/s) with in vivo Tc-99m labeling (110 MBq) of red blood cells was performed for 2 min in the left anterior oblique projection. Five minutes later, a 1-min equilibrium image was obtained, and a blood sample was taken for calculation of the distribution volume. To obtain data for the new method, further radionuclide angiography (1 frame/sec) with 99mTc labeling (600-740 MBq) of red blood cells was then performed in the anterior projection. CO was calculated using the following equation: CO = C-max x V-LV/integral f(t)dt. where C-max is the background-corrected peak count of the whole thorax during angiography, integral f(t)dt is the area under the gamma variate-fitted left ventricular (LV) time-activity curve after background correction and V-LV is the LV volume obtained by the area length method applied to the radionuclide angiography and myocardial tomography In protocol 2, to evaluate the new method, 24 patients (16 men, 8 women; age 71 +/- 9.2 y) underwent radionuclide angiography with Tc-99m-tetrofosmin (600-740 MBq), and the measured CO was compared with the CO obtained by the conventional method with Tc-99m-labeled red blood cells. Results: In protocol 1, good correlation was observed between the CO by the new method (Y) and the CO by the conventional method (X): Y = 1.0X + 57 mL/min and r = 0.95. There was good agreement between the two methods (mean difference -56 +/- 381 mL/min). Inter- and intraobserver correlation coefficients were 0.96 and 0.98, respectively. In protocol 2, the CO by the new method using 99mTc-tetrofosmin (Y) showed a good correlation with the CO by the conventional method (X): Y = 0.90X + 453 mL/min and r = 0.93. Good agreement between the two methods was observed (mean difference 73 +/- 390 mL/min), Inter- and intraobserver correlation coefficients were 0.95 and 0.98, respectively. Conclusion: This new method permits accu- rate forward CO measurement using the first-pass data with Tc-99m-terofosmin, which is applicable to other Tc-99m-labeled myocardial perfusion imaging agents.
引用
收藏
页码:1874 / 1881
页数:8
相关论文
共 50 条
  • [31] DYNAMIC FRACTIONAL FLOW RESERVE MEASUREMENT: POTENTIAL IMPLICATIONS FOR DYNAMIC FIRST-PASS MYOCARDIAL PERFUSION IMAGING
    Barmby, David
    Davies, Andrew
    Gislason-Lee, Amber
    Sivananthan, Mohan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A1299 - A1299
  • [32] A relative quantitative assessment of myocardial perfusion by first-pass technique: animal study
    Chen, Jun
    Zhang, Zhang
    Yu, Xuefang
    Zhou, Kenneth J.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES VIII, 2015, 9315
  • [33] 99mTc-labeled benzothiazole and stilbene derivatives as imaging agents for Aβ plaques in cerebral amyloid angiopathy
    Jia, Jianhua
    Cui, Mengchao
    Dai, Jiapei
    Wang, Xuedan
    Ding, Yu-Shin
    Jia, Hongmei
    Liu, Boli
    MEDCHEMCOMM, 2014, 5 (02) : 153 - 158
  • [34] Multislice first-pass cardiac perfusion MRI: Validation in a model of myocardial infarction
    Epstein, FH
    London, JF
    Peters, DC
    Goncalves, LM
    Agyeman, K
    Taylor, J
    Balaban, RS
    Arai, AE
    MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (03) : 482 - 491
  • [35] 99mTc-labeled benzothiazole and stilbene derivatives as imaging agents for Aβ plaques in Cerebral Amyloid Angiopathy
    Jia Jianhua
    Cui Mengchao
    Dai Jiapei
    Wang Xuedan
    Li Zijing
    Yu Pingrong
    Yang Yanping
    Fu Hualong
    Ding Yu-Shin
    Jia Hongmei
    Liu Boli
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2013, 56 : S283 - S283
  • [36] Fast mapping of myocardial blood flow with MR first-pass perfusion imaging
    Goldstein, Thomas A.
    Jerosch-Herold, Michael
    Misselwitz, Bernd
    Zhang, Haosen
    Gropler, Robert J.
    Zheng, Jie
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (06) : 1394 - 1400
  • [37] MYOCARDIAL PERFUSION IMAGING WITH TC-99M-LABELED AGENTS
    MADDAHI, J
    KIAT, H
    BERMAN, DS
    AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (14): : D27 - D34
  • [38] Technetium-99m labeled myocardial perfusion imaging agents
    Jain, D
    SEMINARS IN NUCLEAR MEDICINE, 1999, 29 (03) : 221 - 236
  • [39] High Resolution Myocardial First-Pass Perfusion Imaging With Extended Anatomic Coverage
    Staeb, Daniel
    Wech, Tobias
    Breuer, Felix A.
    Weng, Andreas Max
    Ritter, Christian Oliver
    Hahn, Dietbert
    Koestler, Herbert
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (06) : 1575 - 1587
  • [40] Contrast-dose relation in first-pass myocardial MR perfusion imaging
    Utz, Wolfgang
    Niendorf, Thoralf
    Wassmuth, Ralf
    Messroghli, Daniel
    Dietz, Rainer
    Schulz-Menger, Jeanette