Forward cardiac output measurement with first-pass technique using 99mTc-labeled myocardial perfusion imaging agents

被引:0
|
作者
Taki, J
Muramori, A
Kinuya, S
Nakajima, K
Matsunari, I
Miyazaki, Y
Murata, Y
Tonami, N
机构
[1] Kanazawa Univ, Sch Med, Dept Nucl Med, Kanazawa, Ishikawa 9208640, Japan
[2] Noto Gen Hosp, Dept Radiol, Div Nucl Med, Nanao, Japan
[3] Noto Gen Hosp, Dept Internal Med, Div Cardiol, Nanao, Japan
关键词
forward cardiac output; Tc-99m-labeled myocardial agents; tetrofosmin; radionuclide angiography;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to develop and validate a new first-pass method for the measurement of forward cardiac output (CO) using Tc-99m-labeled myocardial perfusion imaging agents. Methods: In protocol 1, to test the new method for measuring CO, the conventional method and the new method for CO measurement were performed in 1 d in 57 patients (32 men, 25 women; age 68 +/- 11 y). In the conventional method, radionuclide angiography (1 frame/s) with in vivo Tc-99m labeling (110 MBq) of red blood cells was performed for 2 min in the left anterior oblique projection. Five minutes later, a 1-min equilibrium image was obtained, and a blood sample was taken for calculation of the distribution volume. To obtain data for the new method, further radionuclide angiography (1 frame/sec) with 99mTc labeling (600-740 MBq) of red blood cells was then performed in the anterior projection. CO was calculated using the following equation: CO = C-max x V-LV/integral f(t)dt. where C-max is the background-corrected peak count of the whole thorax during angiography, integral f(t)dt is the area under the gamma variate-fitted left ventricular (LV) time-activity curve after background correction and V-LV is the LV volume obtained by the area length method applied to the radionuclide angiography and myocardial tomography In protocol 2, to evaluate the new method, 24 patients (16 men, 8 women; age 71 +/- 9.2 y) underwent radionuclide angiography with Tc-99m-tetrofosmin (600-740 MBq), and the measured CO was compared with the CO obtained by the conventional method with Tc-99m-labeled red blood cells. Results: In protocol 1, good correlation was observed between the CO by the new method (Y) and the CO by the conventional method (X): Y = 1.0X + 57 mL/min and r = 0.95. There was good agreement between the two methods (mean difference -56 +/- 381 mL/min). Inter- and intraobserver correlation coefficients were 0.96 and 0.98, respectively. In protocol 2, the CO by the new method using 99mTc-tetrofosmin (Y) showed a good correlation with the CO by the conventional method (X): Y = 0.90X + 453 mL/min and r = 0.93. Good agreement between the two methods was observed (mean difference 73 +/- 390 mL/min), Inter- and intraobserver correlation coefficients were 0.95 and 0.98, respectively. Conclusion: This new method permits accu- rate forward CO measurement using the first-pass data with Tc-99m-terofosmin, which is applicable to other Tc-99m-labeled myocardial perfusion imaging agents.
引用
收藏
页码:1874 / 1881
页数:8
相关论文
共 50 条
  • [21] Synthesis, evaluation, and comparison of 99mTc-labeled bisphosphonates as potential bone imaging agents
    Luo, Shi
    Qiu, Ling
    Lin, Jian
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [22] 235 Simultaneous myocardial first-pass perfusion and strain imaging with DENSE
    Yuan Le
    Kellman Peter
    Joni Taylor
    Eric Bennett
    Katherine Lucas
    Christophe Chefd'Hotel
    Christine H Lorenz
    Han Wen
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [23] 99mTc-labeled long chain fatty acid derivative for myocardial imaging.
    Magata, Y
    Kawaguchi, T
    Tenma, T
    Mukai, T
    Konishi, J
    Saji, H
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 260P - 260P
  • [24] MULTISLICE FIRST-PASS MYOCARDIAL PERFUSION IMAGING ON A CONVENTIONAL CLINICAL SCANNER
    WALSH, EG
    DOYLE, M
    LAWSON, MA
    BLACKWELL, GG
    POHOST, GM
    MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) : 39 - 47
  • [25] Optimal timing for first-pass stress CT myocardial perfusion imaging
    Bischoff, Bernhard
    Bamberg, Fabian
    Marcus, Roy
    Schwarz, Florian
    Becker, Hans-Christoph
    Becker, Alexander
    Reiser, Maximilian
    Nikolaou, Konstantin
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (02): : 435 - 442
  • [26] Optimal timing for first-pass stress CT myocardial perfusion imaging
    Bernhard Bischoff
    Fabian Bamberg
    Roy Marcus
    Florian Schwarz
    Hans-Christoph Becker
    Alexander Becker
    Maximilian Reiser
    Konstantin Nikolaou
    The International Journal of Cardiovascular Imaging, 2013, 29 : 435 - 442
  • [27] A Low-Dose Prospective First-Pass Analysis Dynamic CT Perfusion Technique for Accurate Myocardial Perfusion Measurement
    Hubbard, L.
    Malkasian, S.
    Dertli, B.
    Kwon, J.
    Abbona, P.
    Molloi, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 3021 - 3021
  • [28] Magnetic resonance myocardial first-pass perfusion imaging: Parameter optimization for signal response and cardiac coverage
    Bertschinger, KM
    Nanz, D
    Buechi, M
    Luescher, TF
    Marincek, B
    von Schulthess, GK
    Schwitter, J
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (05) : 556 - 562
  • [29] Assessment of tumor imaging using 99mTc-labeled Guanine analogue.
    Ozaki, K
    Yang, DJ
    Hamidzadeh, A
    Hu, MC
    Saso, H
    Yu, D
    Kohanim, S
    Kim, EE
    Podoloff, DA
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 298P - 298P
  • [30] Regional myocardial perfusion abnormalities: Fractional flow reserve versus cardiac magnetic resonance first-pass perfusion imaging
    Neizel M.
    Kaestner W.
    Kelm M.
    Kühl H.P.
    Current Cardiovascular Imaging Reports, 2009, 2 (2) : 124 - 129