Simultaneous dual-energy X-ray stereo imaging

被引:7
|
作者
Mokso, Rajmund [1 ]
Oberta, Peter [2 ,3 ]
机构
[1] Paul Scherrer Inst, Swiss Light Source, CH-5232 Villigen, Switzerland
[2] Acad Sci Czech Republ, Inst Phys, Vvi, Prague 8, Czech Republic
[3] Rigaku Innovat Technol Europe Sro, Prague 4, Czech Republic
来源
关键词
optics; crystals; imaging; dual-energy; SYNCHROTRON-RADIATION; CORONARY-ANGIOGRAPHY; RADIOGRAPHY;
D O I
10.1107/S1600577515006554
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Dual-energy or K-edge imaging is used to enhance contrast between two or more materials in an object and is routinely realised by acquiring two separate X-ray images each at different X-ray wavelength. On a broadband synchrotron source an imaging system to acquire the two images simultaneously was realised. The single-shot approach allows dual-energy and stereo imaging to be applied to dynamic systems. Using a Laue-Bragg crystal splitting scheme, the X-ray beam was split into two and the two beam branches could be easily tuned to either the same or to two different wavelengths. Due to the crystals' mutual position, the two beam branches intercept each other under a non-zero angle and create a stereoscopic setup.
引用
收藏
页码:1078 / 1082
页数:5
相关论文
共 50 条
  • [41] X-Ray Spectra Optimization for Dual-Energy Imaging Using Dual-Source CT
    Giraldo, J. Ramirez
    Primak, A.
    Liu, X.
    McCollough, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [42] Dual-energy X-ray absorptiometry scan: Guidelines
    Haymann, Jean-Philippe
    PROGRES EN UROLOGIE, 2010, 20 (04): : F119 - F122
  • [43] DUAL-ENERGY X-RAY ABSORPTIOMETRY IN NEUROMUSCULAR DISEASES
    KANDA, F
    FUJII, Y
    TAKAHASHI, K
    FUJITA, T
    MUSCLE & NERVE, 1994, 17 (04) : 431 - 435
  • [44] DUAL-ENERGY X-RAY ABSORPTIOMETRY - INTEREST IN ORTHOPEDICS
    MAUGARS, Y
    BERTHELOT, JM
    DELECRIN, J
    TRECANT, M
    PASSUTI, N
    DACULSI, G
    PROST, A
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1995, 81 (04): : 326 - 332
  • [45] Technical standardization for dual-energy X-ray absorptiometry
    Leib, E
    JOURNAL OF CLINICAL DENSITOMETRY, 2004, 7 (01) : 27 - 36
  • [46] Dual-energy X-ray absorptiometry in early life
    Lapillonne, A
    Braillon, PM
    Delmas, PD
    Salle, BL
    HORMONE RESEARCH, 1997, 48 : 43 - 49
  • [47] SIMULATION STUDIES OF DUAL-ENERGY X-RAY ABSORPTIOMETRY
    SORENSON, JA
    DUKE, PR
    SMITH, SW
    MEDICAL PHYSICS, 1989, 16 (01) : 75 - 80
  • [48] Dual-energy X-ray absorptiometry and body composition
    Laskey, MA
    NUTRITION, 1996, 12 (01) : 45 - 51
  • [49] The use of dual-energy x-ray absorptiometry in animals
    Grier, SJ
    Turner, AS
    Alvis, MR
    INVESTIGATIVE RADIOLOGY, 1996, 31 (01) : 50 - 62
  • [50] ENHANCED PRECISION WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY
    MAZESS, R
    CHESNUT, CH
    MCCLUNG, M
    GENANT, H
    CALCIFIED TISSUE INTERNATIONAL, 1992, 51 (01) : 14 - 17