Simultaneous dual-energy X-ray stereo imaging

被引:7
|
作者
Mokso, Rajmund [1 ]
Oberta, Peter [2 ,3 ]
机构
[1] Paul Scherrer Inst, Swiss Light Source, CH-5232 Villigen, Switzerland
[2] Acad Sci Czech Republ, Inst Phys, Vvi, Prague 8, Czech Republic
[3] Rigaku Innovat Technol Europe Sro, Prague 4, Czech Republic
来源
关键词
optics; crystals; imaging; dual-energy; SYNCHROTRON-RADIATION; CORONARY-ANGIOGRAPHY; RADIOGRAPHY;
D O I
10.1107/S1600577515006554
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Dual-energy or K-edge imaging is used to enhance contrast between two or more materials in an object and is routinely realised by acquiring two separate X-ray images each at different X-ray wavelength. On a broadband synchrotron source an imaging system to acquire the two images simultaneously was realised. The single-shot approach allows dual-energy and stereo imaging to be applied to dynamic systems. Using a Laue-Bragg crystal splitting scheme, the X-ray beam was split into two and the two beam branches could be easily tuned to either the same or to two different wavelengths. Due to the crystals' mutual position, the two beam branches intercept each other under a non-zero angle and create a stereoscopic setup.
引用
收藏
页码:1078 / 1082
页数:5
相关论文
共 50 条
  • [31] Quantification of a silver contrast agent in dual-energy breast x-ray imaging
    Karunamuni, Roshan
    Maidment, Andrew D. A.
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [32] Sharpening filter for false color imaging of dual-energy X-ray scans
    Krzysztof Dmitruk
    Marcin Denkowski
    Michał Mazur
    Paweł Mikołajczak
    Signal, Image and Video Processing, 2017, 11 : 613 - 620
  • [33] Theoretical feasibility of dual-energy functional x-ray imaging of respiratory disease
    Tanguay, Jesse
    Kirby, Miranda
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [34] Sharpening filter for false color imaging of dual-energy X-ray scans
    Dmitruk, Krzysztof
    Denkowski, Marcin
    Mazur, Michal
    Mikolajczak, Pawel
    SIGNAL IMAGE AND VIDEO PROCESSING, 2017, 11 (04) : 613 - 620
  • [35] Preliminary research on dual-energy X-ray phase-contrast imaging
    韩华杰
    王圣浩
    高昆
    王志立
    张灿
    杨萌
    张凯
    朱佩平
    Chinese Physics C, 2016, (04) : 147 - 154
  • [36] Preliminary research on dual-energy X-ray phase-contrast imaging
    Han, Hua-Jie
    Wang, Sheng-Hao
    Gao, Kun
    Wang, Zhi-Li
    Zhang, Can
    Yang, Meng
    Zhang, Kai
    Zhu, Pei-Ping
    CHINESE PHYSICS C, 2016, 40 (04)
  • [37] Stereoscopic imaging using folded linear dual-energy x-ray detectors
    Evans, JPO
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2002, 13 (09) : 1388 - 1397
  • [38] Preliminary research on dual-energy X-ray phase-contrast imaging
    韩华杰
    王圣浩
    高昆
    王志立
    张灿
    杨萌
    张凯
    朱佩平
    Chinese Physics C, 2016, 40 (04) : 147 - 154
  • [39] Dual-energy computed tomography imaging with megavoltage and kilovoltage X-ray spectra
    Jadick, Giavanna
    Schlafly, Geneva
    La Riviere, Patrick J.
    JOURNAL OF MEDICAL IMAGING, 2024, 11 (02)
  • [40] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE CALCANEUS - COMPARISON WITH VERTEBRAL DUAL-ENERGY X-RAY ABSORPTIOMETRY AND QUANTITATIVE COMPUTED-TOMOGRAPHY
    LAVALJEANTET, AM
    BERGOT, C
    WILLIAMS, M
    DAVIDSON, K
    LAVALJEANTET, M
    CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (01) : 14 - 18