Timing alignment study of PMT-Quadrant-Sharing (PQS) detectors for Time-of-Flight PET

被引:0
|
作者
An, Shaohui [1 ]
Li, Hongdi [1 ]
Liu, Shitao [1 ]
Ramirez, Rocio [1 ]
Zhang, Yuxuan [1 ]
Wang, Chao [1 ]
Baghaei, Hossain [1 ]
Wong, Wai-Hoi [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Expt Diagnost Imaging, Houston, TX 77030 USA
关键词
coincidence timing resolution; digital data processing; PQS LYSO block; time-of-flight PET; RESOLUTION; LSO;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We developed a digital signal processing method to measure the coincidence timing resolution of a 13x13 (4x4x20 mm(3)) PQS LYSO block coupled with Hamamatsu R9779 PMT and investigated the time alignment effect. A single LYSO (4x4x20 mm(3)) coupled with R9779 was used as a timing measurement reference which has a resolution of 214 ps (FHWM). Signals from PMTs were captured by oscilloscope and analyzed in Labview. Linear fitting and extrapolation to the baseline of the pulse rising edge was used to get the pulse arrival time. By adjusting the output cable length of each PMT, the timing resolution of each crystal in the block was measured with both aligned and unaligned PMT timing. The relationship between the timing resolution of each crystal and the delay time of one of the four PMT was investigated. The result shows that a timing misalignment of 500 ps only worsens the timing resolution by 20 ps. Further more, the regional timing variance on the photocathode of R9779 was also measured by coupling a single LYSO to different locations on its glass window. The coincidence timing resolutions of the 13x13 block with two set-ups of different PMT rotational orientations were compared. The result shows that the timing response difference on the photocathode of R9779 which was measured to be 110 ps has no obvious effect to the timing resolution.
引用
下载
收藏
页码:2758 / 2760
页数:3
相关论文
共 50 条
  • [41] A fast preamplifier concept for SiPM-based time-of-flight PET detectors
    Huizenga, J.
    Seifert, S.
    Schreuder, F.
    van Dam, H. T.
    Dendooven, P.
    Lohner, H.
    Vinke, R.
    Schaart, D. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 695 : 379 - 384
  • [42] Front-end electronics based on high-yield-pileup-event-recovery method for a high resolution PET camera with PMT-quadrant-sharing detector modules
    Li, HD
    Wong, WH
    Wang, Y
    Liu, YQ
    Xing, T
    Uribe, J
    Baghaei, H
    Farrell, R
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 699 - 703
  • [43] Timing performance of Hi-Rez detector for time-of-flight (TOF) PET
    Aykac, Mehmet
    Bauer, Florian
    Williams, Charles W.
    Loope, Michael
    Schmand, Matthias
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 1084 - 1089
  • [44] Consistency equations in native detector coordinates and timing calibration for time-of-flight PET
    Li, Yusheng
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (02):
  • [45] Timing performance of Hi-Rez detector for time-of-flight (TOF) PET
    Aykac, Mehmet
    Bauer, Florian
    Williams, Charles W.
    Loope, Michael
    Schmand, Matthias
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2035 - 2040
  • [46] Estimation of Timing Resolution for Very Fast Time-Of-Flight Detectors in Monte Carlo Simulations
    Efthimiou, Nikos
    Emond, Elise
    Cawthorne, Chris
    Tsoumpas, Charalampos
    Thielemans, Kris
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [47] TDC Array Tradeoffs in Current and Upcoming Digital SiPM Detectors for Time-of-Flight PET
    Tetrault, Marc-Andre
    Therrien, Audrey Corbeil
    Lemaire, William
    Fontaine, Rejean
    Pratte, Jean-Francois
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2017, 64 (03) : 925 - 932
  • [48] A Light Sharing, Charge Multiplexed Time-of-Flight Depth-of-Interaction PET Detector
    Bieniosek, Matthew F.
    Cates, Joshua W.
    Levin, Craig S.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [49] Theoretical Investigation of the Effects of Timing Calibration Errors on Time-of-Flight PET Image Quality
    Manjeshwar, Ravindra
    Asma, Evren
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4441 - 4444
  • [50] On timing-optimized SiPMs for Cherenkov detection to boost low cost time-of-flight PET
    Gundacker, Stefan
    Borghi, Giacomo
    Cherry, Simon R.
    Gola, Alberto
    Lee, Daehee
    Merzi, Stefano
    Penna, Michele
    Schulz, Volkmar
    Kwon, Sun Il
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (16):