Timing alignment study of PMT-Quadrant-Sharing (PQS) detectors for Time-of-Flight PET

被引:0
|
作者
An, Shaohui [1 ]
Li, Hongdi [1 ]
Liu, Shitao [1 ]
Ramirez, Rocio [1 ]
Zhang, Yuxuan [1 ]
Wang, Chao [1 ]
Baghaei, Hossain [1 ]
Wong, Wai-Hoi [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Expt Diagnost Imaging, Houston, TX 77030 USA
关键词
coincidence timing resolution; digital data processing; PQS LYSO block; time-of-flight PET; RESOLUTION; LSO;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We developed a digital signal processing method to measure the coincidence timing resolution of a 13x13 (4x4x20 mm(3)) PQS LYSO block coupled with Hamamatsu R9779 PMT and investigated the time alignment effect. A single LYSO (4x4x20 mm(3)) coupled with R9779 was used as a timing measurement reference which has a resolution of 214 ps (FHWM). Signals from PMTs were captured by oscilloscope and analyzed in Labview. Linear fitting and extrapolation to the baseline of the pulse rising edge was used to get the pulse arrival time. By adjusting the output cable length of each PMT, the timing resolution of each crystal in the block was measured with both aligned and unaligned PMT timing. The relationship between the timing resolution of each crystal and the delay time of one of the four PMT was investigated. The result shows that a timing misalignment of 500 ps only worsens the timing resolution by 20 ps. Further more, the regional timing variance on the photocathode of R9779 was also measured by coupling a single LYSO to different locations on its glass window. The coincidence timing resolutions of the 13x13 block with two set-ups of different PMT rotational orientations were compared. The result shows that the timing response difference on the photocathode of R9779 which was measured to be 110 ps has no obvious effect to the timing resolution.
引用
下载
收藏
页码:2758 / 2760
页数:3
相关论文
共 50 条
  • [21] Low-cost High-resolution 3rd Generation PMT-Quadrant-Sharing BGO Block Detectors for Human and Animal PET
    Liu, Shitao
    Kim, Soonseok
    Li, Hongdi
    Ramirez, Rocio A.
    Liu, Jiguo
    Wang, Yu
    Zhang, Yuxuan
    Baghaei, Hossain
    Wong, Wai-Hoi
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1900 - 1903
  • [22] OPTIMIZATION OF DETECTORS FOR TIME-OF-FLIGHT PET
    Moszynski, Marek
    Szczesniak, Tomasz
    WORKSHOP ON TIMING DETECTORS: ELECTRONICS, MEDICAL AND PARTICLE PHYSICS APPLICATIONS, 2010, 4 (01): : 59 - 64
  • [23] Front end electronics for a variable field PET camera using the PMT-quadrant-sharing detector array design
    Wong, WH
    Hu, GJ
    Zhang, N
    Uribe, J
    Wang, JM
    Li, HD
    Lu, WH
    Baghaei, H
    Yokoyama, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 1291 - 1296
  • [24] Front end electronics for a variable field PET camera using the PMT-quadrant-sharing detector array design
    Wong, WH
    Hu, GJ
    Zhang, N
    Uribe, J
    Wang, JM
    Li, HD
    Lu, WZ
    Baghaei, H
    Yokoyama, S
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1320 - 1324
  • [25] Physics and technology of time-of-flight PET detectors
    Schaart, Dennis R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (09):
  • [26] A linear estimator for timing calibration in time-of-flight PET
    Defrise, Michel
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [27] MCP PMT with high time response and linear output current for neutron time-of-flight detectors
    Dolotov, A. S.
    Konovalov, P. I.
    Nurtdinov, R. I.
    II CONFERENCE ON PLASMA & LASER RESEARCH AND TECHNOLOGIES, 2016, 747
  • [28] Investigation of a Multi-Anode Microchannel Plate PMT for Time-of-Flight PET
    Choong, Woon-Seng
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (05) : 2417 - 2423
  • [29] Colored reflectors to improve coincidence timing resolution of BGO-based time-of-flight PET detectors
    Lee, Daehee
    Cherry, Simon R.
    Kwon, Sun Il
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (18):
  • [30] The Minimum Achievable Timing Resolution with High-Aspect-Ratio Scintillation Detectors for Time-of-Flight PET
    Cates, J. W.
    Vinke, R.
    Levin, C. S.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,