Dose assurance service for low energy X-ray irradiators using an alanine-EPR transfer dosimetry system

被引:0
|
作者
Khoury, Helen J. [1 ]
Mehta, Kishor
de Barros, Vinicius S. [1 ]
Guzzo, Pedro L. [2 ]
Parker, Andrew G. [3 ]
机构
[1] Univ Fed Pernambuco, Dept Nucl Energy, BR-50740540 Recife, PE, Brazil
[2] Univ Fed Pernambuco, Dept Min Engn, BR-50740540 Recife, PE, Brazil
[3] IAEA, Joint FAO IAEA Div Nucl Tech Food & Agr, Insect Pest Control Lab, A-1400 Vienna, Austria
关键词
dose control; SIT applications; self-shielded X-irradiators; solid state dosimetry;
D O I
暂无
中图分类号
Q96 [昆虫学];
学科分类号
摘要
In recent years, X-ray irradiators have been introduced as an alternative to gamma irradiators due to the problems with the acquisition, transport and security of radioactive sources. Self-shielded low energy X-ray irradiators (such as the RS 2400) were developed to complement and eventually replace gamma sources. These irradiators are quite suitable for sterilizing insects for SIT applications, as well as for research on quarantine treatments of food and phytosanitary applications. During the irradiation of an agricultural product the absorbed dose inside the canister must be controlled to ensure that the desired effect is achieved without deleteriously affecting the product. The focus of this paper is to describe the Dose Assurance Service offered by the Insect Pest Control Laboratory of the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture using an alanine-EPR dosimetry system as a transfer standard for low energy X-radiation. All the administrative and technical issues are now finalized and the dose assurance service is ready for operation. The purpose of this Service is to help facilities using such irradiators to check the quality of their dosimetry systems.
引用
收藏
页码:14 / 17
页数:4
相关论文
共 50 条
  • [11] Dosimetry of Low Energy Electronic Brachytherapy X-Ray Source
    Kriminski, S.
    Dorgu, A.
    Gong, J.
    Pavord, D.
    MEDICAL PHYSICS, 2010, 37 (06) : 3364 - +
  • [12] Low energy ion beam monitoring system by dosimetry film and particle induced X-ray
    Choi, H. W.
    Woo, H. J.
    Park, J. H.
    Lee, G. H.
    Kim, G. D.
    Kim, J. K.
    Hong, W.
    Eum, C. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 261 (1-2): : 102 - 105
  • [13] INTERCOMPARISON OF GAMMA-RAY, X-RAY, AND FAST-NEUTRON DOSIMETRY USING ALANINE DETECTORS
    HANSEN, JW
    WALIGORSKI, MPR
    BYRSKI, E
    RADIATION PROTECTION DOSIMETRY, 1989, 27 (02) : 85 - 92
  • [14] Monte-Carlo dosimetry for intraoperative radiotherapy using a low energy x-ray source
    Bouzid, Dounia
    Bert, Julien
    Dupre, Pierre-Francois
    Benhalouche, Saadia
    Pradier, Olivier
    Boussion, Nicolas
    Visvikis, Dimitris
    ACTA ONCOLOGICA, 2015, 54 (10) : 1788 - 1795
  • [15] Determination of the absorbed dose to water for medium-energy x-ray beams using Fricke dosimetry
    Rosado, Paulo Henrique
    Salata, Camila
    David, Mariano Gazineu
    Mantuano, Andrea
    Pickler, Arissa
    Mota, Carla Lemos
    de Almeida, Carlos E.
    MEDICAL PHYSICS, 2020, 47 (11) : 5802 - 5809
  • [16] Low Dose, Limited Energy Spectroscopic X-ray Microscopy
    Weker, Johanna Nelson
    Li, Yiyang
    Chueh, William C.
    X-RAY NANOIMAGING: INSTRUMENTS AND METHODS II, 2015, 9592
  • [17] Linearity and reproducibility response of Fricke dosimetry for low energy X-Ray beam
    Mantuano, A.
    de Amorim, G. J.
    David, M. G.
    Rosado, P. H. G.
    Salata, C.
    Magalhaes, L. A. G.
    deAlmeida, C. E.
    9TH BRAZILIAN CONGRESS ON METROLOGY (METROLOGIA 2017), 2018, 975
  • [18] Absorbed dose to water determination for kilo-voltage X-rays using alanine/EPR dosimetry systems
    Nasreddine, Abbas
    Kuntz, Florent
    El Bitar, Ziad
    RADIATION PHYSICS AND CHEMISTRY, 2021, 180 (180)
  • [19] COMPLICATIONS IN LOW-ENERGY X-RAY DOSIMETRY CAUSED BY ELECTRON CONTAMINATION
    KLEVENHAGEN, SC
    DSOUZA, D
    BONNEFOUX, I
    PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (08): : 1111 - 1116
  • [20] A Preliminary Study on Low-dose X-ray Imaging Using Parametric X-ray
    Sakae, Toshiro
    Hayakawa, Yasushi
    Takahashi, Yumiko
    Kuwada, Takao
    Nakao, Keisuke
    Nogami, Kyoko
    Inagaki, Manabu
    Tanaka, Toshinari
    Sato, Isamu
    Hirayama, Katsunori
    Sekiya, Kotarou
    Kaneda, Takashi
    Suemitsu, Masaaki
    Okada, Hiroyuki
    Yamamoto, Hirotsugu
    Hata, Saya
    Akimoto, Yoshiaki
    Fukumoto, Masahiko
    Makimura, Masaharu
    JOURNAL OF HARD TISSUE BIOLOGY, 2011, 20 (01) : 31 - 35