Sample size requirements for estimating effective dose from computed tomography using solid-state metal-oxide-semiconductor field-effect transistor dosimetry

被引:4
|
作者
Trattner, Sigal [1 ,2 ]
Cheng, Bin [3 ]
Pieniazek, Radoslaw L. [2 ,4 ]
Hoffmann, Udo [5 ,6 ]
Douglas, Pamela S. [7 ]
Einstein, Andrew J. [1 ,2 ,8 ]
机构
[1] Columbia Univ, Med Ctr, Dept Med, Div Cardiol, New York, NY 10032 USA
[2] New York Presbyterian Hosp, New York, NY 10032 USA
[3] Columbia Univ, Mailman Sch Publ Hlth, Dept Biostat, New York, NY 10032 USA
[4] Columbia Univ, Med Ctr, Ctr Radiol Res, New York, NY 10032 USA
[5] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[6] Harvard Univ, Sch Med, Boston, MA 02114 USA
[7] Duke Univ, Dept Med, Div Cardiol, Durham, NC 27715 USA
[8] Columbia Univ, Med Ctr, Dept Radiol, New York, NY 10032 USA
关键词
effective dose; MOSFET; computer tomography; dosimetry; sample size; CT ANGIOGRAPHY; PHANTOM; TECHNOLOGY;
D O I
10.1118/1.4868693
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (MOSFET) solid-state dosimeters have been placed to enable organ dose measurements. Here a statistical framework is established to determine the sample size (number of scans) needed for estimating ED to a desired precision and confidence, for a particular scanner and scan protocol, subject to practical limitations. Methods: The statistical scheme involves solving equations which minimize the sample size required for estimating ED to desired precision and confidence. It is subject to a constrained variation of the estimated ED and solved using the Lagrange multiplier method. The scheme incorporates measurement variation introduced both by MOSFET calibration, and by variation in MOSFET readings between repeated CT scans. Sample size requirements are illustrated on cardiac, chest, and abdomen-pelvis CT scans performed on a 320-row scanner and chest CT performed on a 16-row scanner. Results: Sample sizes for estimating ED vary considerably between scanners and protocols. Sample size increases as the required precision or confidence is higher and also as the anticipated ED is lower. For example, for a helical chest protocol, for 95% confidence and 5% precision for the ED, 30 measurements are required on the 320-row scanner and 11 on the 16-row scanner when the anticipated ED is 4 mSv; these sample sizes are 5 and 2, respectively, when the anticipated ED is 10 mSv. Conclusions: Applying the suggested scheme, it was found that even at modest sample sizes, it is feasible to estimate ED with high precision and a high degree of confidence. As CT technology develops enabling ED to be lowered, more MOSFET measurements are needed to estimate ED with the same precision and confidence. (c) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Operation of ferroelectric gate field-effect transistor memory with intermediate electrode using polycrystalline capacitor and metal-oxide-semiconductor field-effect transistor
    Trinh, Bui Nguyen Quoc
    Horita, Susumu
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (9B): : 7341 - 7344
  • [22] A spin metal-oxide-semiconductor field-effect transistor (spin MOSIFET) with a ferromagnetic semiconductor for the channel
    Sugahara, S
    Tanaka, M
    JOURNAL OF APPLIED PHYSICS, 2005, 97 (10)
  • [23] Shot noise model of the short channel metal-oxide-semiconductor field-effect transistor
    Zhang Meng
    Yao Ruo-He
    Liu Yu-Rong
    Geng Kui-Wei
    ACTA PHYSICA SINICA, 2020, 69 (17)
  • [24] The drain velocity overshoot in an 80 nm metal-oxide-semiconductor field-effect transistor
    Tan, Michael L. P.
    Arora, Vijay K.
    Saad, Ismail
    Ahmadi, Mohammad Taghi
    Ismail, Razali
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (07)
  • [25] The drain velocity overshoot in an 80 nm metal-oxide-semiconductor field-effect transistor
    Tan, Michael L. P.
    Arora, Vijay K.
    Saad, Ismail
    Taghi Ahmadi, Mohammad
    Ismail, Razali
    Journal of Applied Physics, 2009, 105 (07):
  • [26] Ge/Si quantum-dot metal-oxide-semiconductor field-effect transistor
    Yakimov, AI
    Dvurechenskii, AV
    Kirienko, VV
    Nikiforov, AI
    APPLIED PHYSICS LETTERS, 2002, 80 (25) : 4783 - 4785
  • [27] Sharp Resonance in a Metal-Oxide-Semiconductor Field-Effect Transistor with Multifinger Gate Configuration
    Abe, Kazuhide
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2013, 52 (07)
  • [28] New Insight on Terahertz Rectification in a Metal-Oxide-Semiconductor Field-Effect Transistor Structure
    Palma, Fabrizio
    ELECTRONICS, 2020, 9 (07) : 1 - 11
  • [29] A Diamond: H/WO3 Metal-Oxide-Semiconductor Field-Effect Transistor
    Yin, Zongyou
    Tordjman, Moshe
    Vardi, Alon
    Kalish, Rafi
    del Alamo, Jesus A.
    IEEE ELECTRON DEVICE LETTERS, 2018, 39 (04) : 540 - 543
  • [30] ENERGY-BAND DIAGRAM OF A SI METAL-OXIDE-SEMICONDUCTOR FIELD-EFFECT TRANSISTOR
    FU, Y
    WILLANDER, M
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1995, 42 (08) : 1522 - 1527