Evaluation of Portable Point-of-Care CD4 Counter with High Sensitivity for Detecting Patients Eligible for Antiretroviral Therapy

被引:50
|
作者
Manabe, Yukari C. [1 ,2 ,3 ]
Wang, Yaping [2 ]
Elbireer, Ali [3 ,4 ]
Auerbach, Brandon [1 ]
Castelnuovo, Barbara [1 ]
机构
[1] Makerere Coll Hlth Sci, Infect Dis Inst, Kampala, Uganda
[2] Johns Hopkins Univ, Sch Med, Dept Med, Div Infect Dis, Baltimore, MD 21205 USA
[3] Johns Hopkins Univ, Sch Med, Dept Pathol, Makerere Univ,Clin Core Lab, Baltimore, MD 21205 USA
[4] Johns Hopkins Univ, Sch Med, Dept Med, Div Pathol, Baltimore, MD 21205 USA
来源
PLOS ONE | 2012年 / 7卷 / 04期
关键词
SOUTH-AFRICA; FOLLOW-UP; HIV-1-INFECTED PATIENTS; PERFORMANCE EVALUATION; COLLABORATIVE ANALYSIS; PIMA CD4; COHORT; HIV; INITIATION; ANALYZER;
D O I
10.1371/journal.pone.0034319
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Accurate, inexpensive point-of-care CD4+ T cell testing technologies are needed that can deliver CD4+ T cell results at lower level health centers or community outreach voluntary counseling and testing. We sought to evaluate a point-of-care CD4+ T cell counter, the Pima CD4 Test System, a portable, battery-operated bench-top instrument that is designed to use finger stick blood samples suitable for field use in conjunction with rapid HIV testing. Methods: Duplicate measurements were performed on both capillary and venous samples using Pima CD4 analyzers, compared to the BD FACSCalibur (reference method). The mean bias was estimated by paired Student's t-test. Bland Altman plots were used to assess agreement. Results: 206 participants were enrolled with a median CD4 count of 396 (range; 18-1500). The finger stick PIMA had a mean bias of -66.3 cells/mu L (95% CI -83-4-49.2, P<0.001) compared to the FACSCalibur; the bias was smaller at lower CD4 counts (0-250 cells/mL) with a mean bias of -10.8 (95% CI -27.3-+5.6, P = 0.198), and much greater at higher CD4 cell counts (>500 cells/mu L) with a mean bias of -120.6 (95% CI -162.8, -78.4, P<0.001). The sensitivity (95% CI) of the Pima CD4 analyzer was 96.3% (79.1-99.8%) for a <250 cells/ul cut-off with a negative predictive value of 99.2% (95.1-99.9%). Conclusions: The Pima CD4 finger stick test is an easy-to-use, portable, relatively fast device to test CD4+ T cell counts in the field. Issues of negatively-biased CD4 cell counts especially at higher absolute numbers will limit its utility for longitudinal immunologic response to ART. The high sensitivity and negative predictive value of the test makes it an attractive option for field use to identify patients eligible for ART, thus potentially reducing delays in linkage to care and ART initiation.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Diagnostic Evaluation of a High-Sensitivity Troponin I Point-of-Care Assay
    Soerensen, Nils A.
    Neumann, Johannes T.
    Ojeda, Francisco
    Giannitsis, Evangelos
    Spanuth, Eberhard
    Blankenberg, Stefan
    Westermann, Dirk
    Zeller, Tanja
    CLINICAL CHEMISTRY, 2019, 65 (12) : 1592 - 1601
  • [42] Multisite Evaluation of Point of Care CD4 Testing in Papua New Guinea
    Malagun, Malin
    Nano, Gideon
    Chevallier, Caroline
    Opina, Ragagalo
    Sawiya, Gola
    Kivavia, Joseph
    Kalinoe, Albina
    Nathaniel, Kathalina
    Kaminiel, Oscillah
    Millan, John
    Carmone, Andrea
    Dini, Mary
    Palou, Theresa
    Topma, Kum
    Lavu, Evelyn
    Markby, Jessica
    PLOS ONE, 2014, 9 (11):
  • [43] Performance evaluation of the Pima™ point-of-care CD4 analyser using capillary blood sampling in field tests in South Africa
    Glencross, Deborah K.
    Coetzee, Lindi M.
    Faal, Mamsallah
    Masango, Martin
    Stevens, Wendy S.
    Venter, W. D. Francois
    Osih, Regina
    JOURNAL OF THE INTERNATIONAL AIDS SOCIETY, 2012, 15
  • [44] Rapid Point-of-Care CD4 Testing at Mobile HIV Testing Sites to Increase Linkage to Care: An Evaluation of a Pilot Program in South Africa
    Larson, Bruce A.
    Schnippel, Kathryn
    Ndibongo, Buyiswa
    Xulu, Thembisile
    Brennan, Alana
    Long, Lawrence
    Fox, Matthew P.
    Rosen, Sydney
    JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2012, 61 (02) : E13 - E17
  • [45] CD4 COUNT AND THE RISK FOR DEATH IN PATIENTS INFECTED WITH HIV RECEIVING ANTIRETROVIRAL THERAPY
    YARCHOAN, R
    VENZON, DJ
    PLUDA, JM
    LIETZAU, J
    WYVILL, KM
    TSIATIS, AA
    STEINBERG, SM
    BRODER, S
    ANNALS OF INTERNAL MEDICINE, 1991, 115 (03) : 184 - 189
  • [46] The effects of CD4 nadirs on vessel stiffness in HIV patients undergoing antiretroviral therapy
    Mikula, Tomasz
    Balsam, Pawel
    Peller, Michal
    Suchacz, Magdalena
    Puchalski, Bartosz
    Koltowski, Lukasz
    Maciejewski, Kacper
    Wiercinska-Drapalo, Alicja
    Opolski, Grzegorz
    Filipiak, Krzysztof J.
    KARDIOLOGIA POLSKA, 2017, 75 (08) : 749 - 757
  • [47] Modelling trends of CD4 counts for patients on antiretroviral therapy (ART): a comprehensive health care clinic in Nairobi, Kenya
    Caroline W. Mugo
    Ziv Shkedy
    Samuel Mwalili
    Tadesse Awoke
    Roel Braekers
    Dolphine Wandede
    Christina Mwachari
    BMC Infectious Diseases, 22
  • [48] Modelling trends of CD4 counts for patients on antiretroviral therapy (ART): a comprehensive health care clinic in Nairobi, Kenya
    Mugo, Caroline W.
    Shkedy, Ziv
    Mwalili, Samuel
    Awoke, Tadesse
    Braekers, Roel
    Wandede, Dolphine
    Mwachari, Christina
    BMC INFECTIOUS DISEASES, 2022, 22 (01)
  • [49] Human Immunodeficiency Virus (HIV)-Infected Patients Accept Finger Stick Blood Collection for Point-Of-Care CD4 Testing
    Daneau, Geraldine
    Gous, Natasha
    Scott, Lesley
    Potgieter, Joachim
    Kestens, Luc
    Stevens, Wendy
    PLOS ONE, 2016, 11 (08):
  • [50] Accuracy of Pima Point-of-Care CD4 Analyzer in Routine Use in Public Health Clinics in Uganda
    Morawski, Bozena M.
    Meya, David B.
    Boulware, David R.
    JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2013, 63 (03) : E113 - E115