Fully 3D iterative CT reconstruction using polar coordinates

被引:12
|
作者
Thibaudeau, Christian [1 ,2 ]
Leroux, Jean-Daniel [2 ]
Fontaine, Rejean [2 ]
Lecomte, Roger [3 ,4 ]
机构
[1] CHU Sherbrooke, Sherbrooke Mol Imaging Ctr, Sherbrooke, PQ J1H 5N4, Canada
[2] Univ Sherbrooke, Dept Elect & Comp Engn, Sherbrooke, PQ J1K 2R1, Canada
[3] Univ Sherbrooke, Sherbrooke Mol Imaging Ctr, Sherbrooke, PQ J1H 5N4, Canada
[4] Univ Sherbrooke, Dept Nucl Med & Radiobiol, Sherbrooke, PQ J1H 5N4, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
computed tomography (CT); iterative reconstruction; polar coordinates; system matrix; ordered subsets; IMAGE-RECONSTRUCTION; ORDERED SUBSETS; DOSE REDUCTION; BACKPROJECTION; ALGORITHM; SCHEME;
D O I
10.1118/1.4822514
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This paper demonstrates the feasibility of fully 3D iterative computed tomography reconstruction of highly resolved fields of view using polar coordinates. Methods: System matrix is computed using a ray-tracing approach in cylindrical or spherical coordinates. By using polar symmetries inherent to the acquisition geometry, the system matrix size can be reduced by a factor corresponding to the number of acquired projections. Such an important decrease in size allows the system matrix to be precomputed, and loaded all at once into memory prior to reconstruction. By carefully ordering the field of view voxels and the sinogram data reconstruction speed is also enhanced by a cache-oblivious computer implementation. The reconstruction algorithm is also compatible with the ordered-subsets acceleration method. A final polar-to-Cartesian transformation is applied to the reconstructed image in order to allow proper visualization. Results: The ray-tracing and reconstruction algorithms were implemented in polar representation. Large 3D system matrices were calculated in cylindrical and spherical coordinates, and the performance assessed against Cartesian ray-tracers in terms of speed and memory requirements. Images of analytical phantoms were successfully reconstructed in both cylindrical and spherical coordinates. Fully 3D images of phantoms and small animals were acquired with a Gamma Medica Triumph X-O small animal CT scanner and reconstructed using the manufacturer's software and the proposed polar approach to demonstrate the accuracy and robustness of the later. The noise was found to be reduced while preserving the same level of spatial resolution, without noticeable polar artifacts. Conclusions: Under a reasonable set of assumptions, the memory size of the system matrix can be reduced by a factor corresponding to the number of projections. Using this strategy, iterative reconstruction from high resolution clinical and preclinical systems can be more easily performed using general-purpose personal computers. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Parallelization of a fully 3D CT iterative reconstruction algorithm
    Keesing, Daniel B.
    O'Sullivan, Joseph A.
    Politte, David G.
    Whiting, Bruce R.
    2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 1240 - +
  • [2] ACCELERATED FULLY 3D ITERATIVE RECONSTRUCTION IN SPECT
    Backfrieder, Werner
    Zwettler, Gerald A.
    23RD EUROPEAN MODELING & SIMULATION SYMPOSIUM, EMSS 2011, 2011, : 100 - 104
  • [3] GPU Acceleration of a Fully 3D Iterative Reconstruction Software for PET using CUDA
    Herraiz, J. L.
    Espana, S.
    Garcia, S.
    Cabido, R.
    Montemayor, A. S.
    Desco, M.
    Vaquero, J. J.
    Udias, J. M.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 4064 - +
  • [4] A fully 3D iterative image reconstruction algorithm incorporatin data corrections
    Iatrou, M
    Ross, SG
    Manjeshwar, RM
    Stearns, CW
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2493 - 2497
  • [5] Fast Method For Reconstruction of 3D Coordinates
    Bolecek, Libor
    Ricny, Vaclav
    Slanina, Martin
    2012 35TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2012, : 740 - 744
  • [6] 3D iterative tomographic reconstruction using graphics processors
    Zolotarev, S. A.
    Vengrinovich, V. L.
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2009, 45 (08) : 582 - 591
  • [7] 3D iterative tomographic reconstruction using graphics processors
    S. A. Zolotarev
    V. L. Vengrinovich
    Russian Journal of Nondestructive Testing, 2009, 45 : 582 - 591
  • [8] Fast iterative image reconstruction methods for fully 3D multispectral bioluminescence tomography
    Ahn, Sangtae
    Chaudhari, Abhijit J.
    Darvas, Felix
    Bouman, Charles A.
    Leahy, Richard M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (14): : 3921 - 3942
  • [9] Analytical volume calculation of voxel fragments for iterative, fully 3D PET reconstruction
    Scheins, JJ
    Herzog, H
    Boschen, F
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2502 - 2506
  • [10] Fully 3D PET Iterative Reconstruction Using Distance-Driven Projectors and Native Scanner Geometry
    Manjeshwar, Ravindra M.
    Ross, Steven G.
    Iatrou, Maria
    Deller, Timothy W.
    Stearns, Charles W.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2804 - 2807