Fully 3D iterative CT reconstruction using polar coordinates

被引:12
|
作者
Thibaudeau, Christian [1 ,2 ]
Leroux, Jean-Daniel [2 ]
Fontaine, Rejean [2 ]
Lecomte, Roger [3 ,4 ]
机构
[1] CHU Sherbrooke, Sherbrooke Mol Imaging Ctr, Sherbrooke, PQ J1H 5N4, Canada
[2] Univ Sherbrooke, Dept Elect & Comp Engn, Sherbrooke, PQ J1K 2R1, Canada
[3] Univ Sherbrooke, Sherbrooke Mol Imaging Ctr, Sherbrooke, PQ J1H 5N4, Canada
[4] Univ Sherbrooke, Dept Nucl Med & Radiobiol, Sherbrooke, PQ J1H 5N4, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
computed tomography (CT); iterative reconstruction; polar coordinates; system matrix; ordered subsets; IMAGE-RECONSTRUCTION; ORDERED SUBSETS; DOSE REDUCTION; BACKPROJECTION; ALGORITHM; SCHEME;
D O I
10.1118/1.4822514
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This paper demonstrates the feasibility of fully 3D iterative computed tomography reconstruction of highly resolved fields of view using polar coordinates. Methods: System matrix is computed using a ray-tracing approach in cylindrical or spherical coordinates. By using polar symmetries inherent to the acquisition geometry, the system matrix size can be reduced by a factor corresponding to the number of acquired projections. Such an important decrease in size allows the system matrix to be precomputed, and loaded all at once into memory prior to reconstruction. By carefully ordering the field of view voxels and the sinogram data reconstruction speed is also enhanced by a cache-oblivious computer implementation. The reconstruction algorithm is also compatible with the ordered-subsets acceleration method. A final polar-to-Cartesian transformation is applied to the reconstructed image in order to allow proper visualization. Results: The ray-tracing and reconstruction algorithms were implemented in polar representation. Large 3D system matrices were calculated in cylindrical and spherical coordinates, and the performance assessed against Cartesian ray-tracers in terms of speed and memory requirements. Images of analytical phantoms were successfully reconstructed in both cylindrical and spherical coordinates. Fully 3D images of phantoms and small animals were acquired with a Gamma Medica Triumph X-O small animal CT scanner and reconstructed using the manufacturer's software and the proposed polar approach to demonstrate the accuracy and robustness of the later. The noise was found to be reduced while preserving the same level of spatial resolution, without noticeable polar artifacts. Conclusions: Under a reasonable set of assumptions, the memory size of the system matrix can be reduced by a factor corresponding to the number of projections. Using this strategy, iterative reconstruction from high resolution clinical and preclinical systems can be more easily performed using general-purpose personal computers. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Fast projectors for iterative 3D PET reconstruction
    Cho, Sanghee
    Li, Quanzheng
    Ahn, Sangtae
    Leahy, Richard M.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1933 - 1937
  • [32] Parallelization and comparison of 3D iterative reconstruction algorithms
    Bilbao-Castro, JR
    Carazo, JM
    Fernández, JJ
    García, I
    12TH EUROMICRO CONFERENCE ON PARALLEL, DISTRIBUTED AND NETWORK-BASED PROCESSING, PROCEEDINGS, 2004, : 96 - 102
  • [33] Improvement of image quality and dose management in CT fluoroscopy by iterative 3D image reconstruction
    Oliver S. Grosser
    Christian Wybranski
    Dennis Kupitz
    Maciej Powerski
    Konrad Mohnike
    Maciej Pech
    Holger Amthauer
    Jens Ricke
    European Radiology, 2017, 27 : 3625 - 3634
  • [34] Fast Variance Computation for Quadratically Penalized Iterative Reconstruction of 3D Axial CT Images
    Schmitt, Stephen M.
    Fessler, Jeffrey A.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3287 - 3292
  • [35] Quadratic Regularization Design for Iterative Reconstruction in 3D multi-slice Axial CT
    Shi, Hugo
    Fessler, Jeffrey A.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2834 - 2836
  • [36] Improvement of image quality and dose management in CT fluoroscopy by iterative 3D image reconstruction
    Grosser, Oliver S.
    Wybranski, Christian
    Kupitz, Dennis
    Powerski, Maciej
    Mohnike, Konrad
    Pech, Maciej
    Amthauer, Holger
    Ricke, Jens
    EUROPEAN RADIOLOGY, 2017, 27 (09) : 3625 - 3634
  • [37] Fully 3D SPECT reconstruction in a Grid architecture
    Backfrieder, W.
    Forster, M.
    Engelbrecht, G.
    Benkner, S.
    Maschek, W.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S103 - S104
  • [38] Fully Automatic 3D Reconstruction of Histological Images
    Bagci, Ulas
    Bai, Li
    2008 IEEE 16TH SIGNAL PROCESSING, COMMUNICATION AND APPLICATIONS CONFERENCE, VOLS 1 AND 2, 2008, : 112 - 115
  • [39] Fully automatic 3D reconstruction of histological images
    Bagci, Ulas
    Bai, Li
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 991 - 994
  • [40] 3D OSEM using planograms coordinates
    Brasse, D
    Kinahan, PE
    Defrise, M
    Clackdoyle, R
    Michel, C
    Comtat, C
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 994 - 997