Atlas based automated segmentation of the quadratus lumborum muscle using non-rigid registration on magnetic resonance images of the thoracolumbar region

被引:4
|
作者
Jurcak, V. [1 ]
Fripp, J. [1 ,2 ]
Engstrom, C. [1 ]
Walker, D. [3 ]
Salvado, O. [2 ]
Ourselin, S. [2 ]
Crozier, S. [1 ]
机构
[1] Univ Queensland, Sch ITEE, Brisbane, Qld 4072, Australia
[2] e Hlth Res Ctr, BioMedIA Lab, Floreat, Australia
[3] Wesley Hosp, Southernex Radiol, Auchenflower, Qld, Australia
关键词
quadratus lumborum; thoracolumbar musculature; automatic segmentation; atlas creation; MRI;
D O I
10.1109/ISBI.2008.4540945
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Large volume asymmetries of the quadratus lumborum (QL) muscle, determined from time- and expertise-intensive manual segmentation of axial magnetic resonance (MR) images, have been associated with an increased risk of developing pars interarticularis stress lesions in the lumbar spine of cricket fast bowlers. The purpose of the present study was to develop an atlas-based automated segmentation procedure to determine QL volume from MR images. An MR database of axial lumbar spine images from 15 fast bowlers and 6 athletic control subjects was used to generate the atlas-based segmentation procedures. Initially, all images were preprocessed with a bias field correction algorithm and reverse diffusion interpolation algorithm followed by affine and non-rigid registration methods to generate firstly an average shape atlas (AVG), then based on propagation of manually segmented QL data, develop a probability atlas for automated QL segmentation to calculate muscle volume. The Dice similarity metric (DSC) was used to compare between the QL volume data from the manual and automated segmentation procedures. The mean DICE similarity coefficients between the manual and atlas-based automated segmentation values for the right and left QL muscle volumes were 0.75 (sd=0.1) and 0.76 (sd=0.09), respectively. These preliminary results for the automated segmentation of the QL are encouraging. Further development of the atlas-based segmentation procedures will involve incorporating hierarchical probability atlases for adjacent thoracolumbar muscles to improve the robustness and accuracy of the morphometric analyses obtained by this statistical shape modeling approach.
引用
收藏
页码:113 / +
页数:2
相关论文
共 50 条
  • [1] AUTOMATED SEGMENTATION OF THE QUADRATUS LUMBORUM MUSCLE FROM MAGNETIC RESONANCE IMAGES USING A HYBRID ATLAS BASED - GEODESIC ACTIVE CONTOUR SCHEME
    Jurcak, V.
    Fripp, J.
    Engstrom, C.
    Walker, D.
    Salvado, O.
    Ourselin, S.
    Crozier, S.
    [J]. 2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 867 - +
  • [2] Automated quantification of myocardial perfusion based on segmentation and non-rigid registration of contrast-enhanced cardiac magnetic resonance images
    Giacomo Tarroni
    Cristiana Corsi
    Federico Veronesi
    James Walter
    Claudio Lamberti
    Roberto M Lang
    Victor Mor-Avi
    Amit R Patel
    [J]. Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [3] Non-Rigid Registration of Medical Images using an Automated Method
    Kotsas, Panos
    [J]. PROCEEDINGS OF WORLD ACADEMY OF SCIENCE, ENGINEERING AND TECHNOLOGY, VOL 7, 2005, 7 : 199 - 201
  • [4] Non-rigid registration of medical images using an automated method
    Kotsas, P
    [J]. ENFORMATIKA, VOL 7: IEC 2005 PROCEEDINGS, 2005, : 199 - 201
  • [5] Atlas-based segmentation of deep brain structures using non-rigid registration
    Khan, Muhammad Faisal
    Mewes, Klaus
    Gross, Robert E.
    Skrinjar, Oskar
    [J]. MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2, 2008, 6918
  • [6] A brain nuclear magnetic resonance image segmentation algorithm based on non-rigid registration
    Peng, Lei
    [J]. TRAITEMENT DU SIGNAL, 2018, 35 (3-4) : 317 - 330
  • [7] A method for non-rigid registration of diffusion tensor magnetic resonance images
    Duda, Jeffrey T.
    Rivera, Mariano
    Alexander, Daniel C.
    Gee, James C.
    [J]. Proceedings of SPIE - The International Society for Optical Engineering, 2003, 5032 II : 1186 - 1196
  • [8] Atlas-based segmentation and tracking of 3D cardiac MR images using non-rigid registration
    Lorenzo-Valdés, M
    Sanchez-Ortiz, GI
    Mohiaddin, R
    Rueckert, D
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION-MICCAI 2002, PT 1, 2002, 2488 : 642 - 650
  • [9] Evaluation of Non-Rigid Registration Parameters for Atlas-based Segmentation of CT Images of Human Cochlea
    Elfarnawany, Mai
    Alam, S. Riyahi
    Agrawal, Sumit K.
    Ladak, Hanif M.
    [J]. MEDICAL IMAGING 2017: IMAGE PROCESSING, 2017, 10133
  • [10] Non-rigid image registration of brain magnetic resonance images using graph-cuts
    So, Ronald W. K.
    Tang, Tommy W. H.
    Chung, Albert C. S.
    [J]. PATTERN RECOGNITION, 2011, 44 (10-11) : 2450 - 2467