The accuracy of computed tomography-based linear measurements of human femora and titanium stem

被引:15
|
作者
Feng, ZD
Ziv, I
Rho, J
机构
[1] SUNY BUFFALO,DEPT ORTHOPAED SURG,BUFFALO,NY 14214
[2] DEPT VET AFFAIRS MED CTR,BUFFALO,NY
关键词
computed tomography; hip arthroplasty; femur; titanium stem; image analysis; profile window; Half-maximum height;
D O I
10.1097/00004424-199606000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. The authors investigate the accuracy of computed tomography linear measurement of femora with titanium stem, and the effect of the stem on these measurements. MATERIALS AND METHODS. Two embedded cadaveric femora, one of them containing a titanium stem, and two cortical bone parallelepipeds were scanned, Thirty-six cross-sections were studied, each measured in two linear directions by the profile window technique, A half-maximum height method was used to determine the cortex-gap-titanium sizes from the computed tomography (CT) images, The accuracy of the measurements from the parallelepipeds, femora, and titanium stem taken from the CT was compared with those taken by a digital caliper of anatomical sections at the same level of the same bone. RESULTS. Computed tomography measurements of the parallelepipeds were similar to the anatomical size (mean relative error 0.04% +/- 0.63%), The mean error and mean relative error of the cadaveric femora CT with and without the stem were similar to the control parallelepipeds. Higher values of error were found for the titanium stem. CONCLUSIONS. The half-maximum height method in the profile window provides an accurate measurement of the femoral cortex and the titanium stem, The presence of the titanium stem in the medullary cavity of the femur did not interfere with the measurements of cortical dimensions.
引用
收藏
页码:333 / 337
页数:5
相关论文
共 50 条
  • [1] Evaluation of the Accuracy of Computed Tomography-Based Navigation for Femoral Stem Orientation and Leg Length Discrepancy
    Kitada, Makoto
    Nakamura, Nobuo
    Iwana, Daiki
    Kakimoto, Akihiro
    Nishii, Takashi
    Sugano, Nobuhiko
    JOURNAL OF ARTHROPLASTY, 2011, 26 (05): : 674 - 679
  • [2] Accuracy of Reference Axes for Femoral Component Rotation in Total Knee Arthroplasty Computed Tomography-Based Study of 2,128 Femora
    Jang, Eugene S.
    Connors-Ehlert, Ronald
    LiArno, Sally
    Geller, Jeffrey A.
    Cooper, H. John
    Shah, Roshan P.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (23):
  • [3] Three-dimensional Analysis of Computed Tomography-Based Navigation System for Total Knee Arthroplasty The Accuracy of Computed Tomography-Based Navigation System
    Mizu-uchi, Hideki
    Matsuda, Shuichi
    Miura, Hiromasa
    Higaki, Hidehiko
    Okazaki, Ken
    Iwamoto, Yukihide
    JOURNAL OF ARTHROPLASTY, 2009, 24 (07): : 1103 - 1110
  • [4] Computed tomography-based measurements of normative liver and spleen volumes in children
    Alves, Vinicius de Padua V.
    Dillman, Jonathan R.
    Somasundaram, Elanchezhian
    Taylor, Zachary P.
    Brady, Samuel L.
    Zhang, Bin
    Trout, Andrew T.
    PEDIATRIC RADIOLOGY, 2023, 53 (03) : 378 - 386
  • [5] Computed tomography-based measurements of normative liver and spleen volumes in children
    Vinicius de Padua V. Alves
    Jonathan R. Dillman
    Elanchezhian Somasundaram
    Zachary P. Taylor
    Samuel L. Brady
    Bin Zhang
    Andrew T. Trout
    Pediatric Radiology, 2023, 53 : 378 - 386
  • [6] Effect of fabric on the accuracy of computed tomography-based finite element analyses of the vertebra
    Wu, Yuanqiao
    Morgan, Elise F.
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2020, 19 (02) : 505 - 517
  • [7] Accuracy of Intraoperative Computed Tomography-Based Navigation for Placement of Percutaneous Pedicle Screws
    Eck, Jason C.
    Lange, Jeffrey
    Street, John
    Lapinsky, Anthony
    DiPaola, Christian P.
    GLOBAL SPINE JOURNAL, 2013, 3 (02) : 103 - 107
  • [8] Accuracy of augmented reality with computed tomography-based navigation in total hip arthroplasty
    Masahiro Hasegawa
    Yohei Naito
    Shine Tone
    Akihiro Sudo
    Journal of Orthopaedic Surgery and Research, 18
  • [9] Effect of fabric on the accuracy of computed tomography-based finite element analyses of the vertebra
    Yuanqiao Wu
    Elise F. Morgan
    Biomechanics and Modeling in Mechanobiology, 2020, 19 : 505 - 517
  • [10] Accuracy of augmented reality with computed tomography-based navigation in total hip arthroplasty
    Hasegawa, Masahiro
    Naito, Yohei
    Tone, Shine
    Sudo, Akihiro
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)