The accuracy of computed tomography-based linear measurements of human femora and titanium stem

被引:15
|
作者
Feng, ZD
Ziv, I
Rho, J
机构
[1] SUNY BUFFALO,DEPT ORTHOPAED SURG,BUFFALO,NY 14214
[2] DEPT VET AFFAIRS MED CTR,BUFFALO,NY
关键词
computed tomography; hip arthroplasty; femur; titanium stem; image analysis; profile window; Half-maximum height;
D O I
10.1097/00004424-199606000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. The authors investigate the accuracy of computed tomography linear measurement of femora with titanium stem, and the effect of the stem on these measurements. MATERIALS AND METHODS. Two embedded cadaveric femora, one of them containing a titanium stem, and two cortical bone parallelepipeds were scanned, Thirty-six cross-sections were studied, each measured in two linear directions by the profile window technique, A half-maximum height method was used to determine the cortex-gap-titanium sizes from the computed tomography (CT) images, The accuracy of the measurements from the parallelepipeds, femora, and titanium stem taken from the CT was compared with those taken by a digital caliper of anatomical sections at the same level of the same bone. RESULTS. Computed tomography measurements of the parallelepipeds were similar to the anatomical size (mean relative error 0.04% +/- 0.63%), The mean error and mean relative error of the cadaveric femora CT with and without the stem were similar to the control parallelepipeds. Higher values of error were found for the titanium stem. CONCLUSIONS. The half-maximum height method in the profile window provides an accurate measurement of the femoral cortex and the titanium stem, The presence of the titanium stem in the medullary cavity of the femur did not interfere with the measurements of cortical dimensions.
引用
收藏
页码:333 / 337
页数:5
相关论文
共 50 条
  • [31] Influence of Scan Resolution, Thresholding, and Reconstruction Algorithm on Computed Tomography-Based Kinematic Measurements
    Tan, Christopher John
    Parr, William C. H.
    Walsh, William R.
    Makara, Mariano
    Johnson, Kenneth A.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2017, 139 (10):
  • [32] Comparison of cephalometric measurements and cone-beam computed tomography-based measurements of palatal bone thickness
    Kim, Young-Jae
    Lim, Sung-Hoon
    Gang, Sung-Nam
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 145 (02) : 165 - 172
  • [33] Computed Tomography-Based Measurements of the Cochlear Duct: Implications for Cochlear Implant Pitch Tuning
    Jiam, Nicole T.
    Gilbert, Melanie
    Mo, Jonathan
    Jiradejvong, Patpong
    Limb, Charles J.
    EAR AND HEARING, 2021, 42 (03): : 732 - 743
  • [34] Computed Tomography-Based Custom-Made Stem for Dysplastic Hips in Japanese Patients
    Kawate, Kenji
    Ohneda, Yutaka
    Ohmura, Tetsuji
    Yajima, Hiroshi
    Sugimoto, Kazuya
    Takakura, Yoshinori
    JOURNAL OF ARTHROPLASTY, 2009, 24 (01): : 65 - 70
  • [35] Computed tomography-based measurements associated with rapid lung function decline in severe asthma
    Sim, Da Woon
    Choi, Sanghun
    Jeong, Jinyoung
    Lee, Suh-Young
    Nam, Young-Hee
    Kim, Byung-Keun
    Lee, Young-Soo
    Shim, Ji-Su
    Yang, Min-Suk
    Kim, Min-Hye
    Kim, So Ri
    Koh, Young-Il
    Kim, Sang-Heon
    Park, Heung-Woo
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2025, 134 (03)
  • [36] Cone beam computed tomography-based models versus multislice spiral computed tomography-based models for assessing condylar morphology
    Gomes, Liliane Rosas
    Gomes, Marcelo Regis
    Goncalves, Joao Roberto
    Ruellas, Antonio Carlos O.
    Wolford, Larry M.
    Paniagua, Beatriz
    Benavides, Erika
    Cevidanes, Lucia Helena Soares
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2016, 121 (01): : 96 - 105
  • [37] Isolated acetabular revision with femoral stem retention using computed tomography-based navigation
    Kubota, Yuta
    Kaku, Nobuhiro
    Tagomori, Hiroaki
    Kataoka, Masashi
    Tsumura, Hiroshi
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2019, 105 (07) : 1311 - 1317
  • [38] Positron Emission Tomography/Computed Tomography-Based Diagnosis of Endotipsitis
    Casas Deza, D.
    Sierra Gabarda, O.
    De los Mozos Ruano, A.
    Lamuela Calvo, L. J.
    Garcia Lopez, S.
    Fuentes Olmo, J.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2021, 116 (06): : 1118 - 1118
  • [39] Accuracy of computed tomography-based three-dimensional preoperative planning for total wrist arthroplasty
    Matsuo, Tomoki
    Iwamoto, Takuji
    Suzuki, Taku
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2023, 48 (05) : 476 - 478
  • [40] Accuracy of Computed Tomography-Based Navigation-Assisted Total Knee Arthroplasty: Outlier Analysis
    Miyasaka, Teruyuki
    Kurosaka, Daisaburo
    Saito, Mitsuru
    Omori, Toshiyuki
    Ikeda, Ryo
    Marumo, Keishi
    JOURNAL OF ARTHROPLASTY, 2017, 32 (01): : 47 - 52