The accuracy of computed tomography-based linear measurements of human femora and titanium stem

被引:15
|
作者
Feng, ZD
Ziv, I
Rho, J
机构
[1] SUNY BUFFALO,DEPT ORTHOPAED SURG,BUFFALO,NY 14214
[2] DEPT VET AFFAIRS MED CTR,BUFFALO,NY
关键词
computed tomography; hip arthroplasty; femur; titanium stem; image analysis; profile window; Half-maximum height;
D O I
10.1097/00004424-199606000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. The authors investigate the accuracy of computed tomography linear measurement of femora with titanium stem, and the effect of the stem on these measurements. MATERIALS AND METHODS. Two embedded cadaveric femora, one of them containing a titanium stem, and two cortical bone parallelepipeds were scanned, Thirty-six cross-sections were studied, each measured in two linear directions by the profile window technique, A half-maximum height method was used to determine the cortex-gap-titanium sizes from the computed tomography (CT) images, The accuracy of the measurements from the parallelepipeds, femora, and titanium stem taken from the CT was compared with those taken by a digital caliper of anatomical sections at the same level of the same bone. RESULTS. Computed tomography measurements of the parallelepipeds were similar to the anatomical size (mean relative error 0.04% +/- 0.63%), The mean error and mean relative error of the cadaveric femora CT with and without the stem were similar to the control parallelepipeds. Higher values of error were found for the titanium stem. CONCLUSIONS. The half-maximum height method in the profile window provides an accurate measurement of the femoral cortex and the titanium stem, The presence of the titanium stem in the medullary cavity of the femur did not interfere with the measurements of cortical dimensions.
引用
收藏
页码:333 / 337
页数:5
相关论文
共 50 条
  • [41] APPLICATION ACCURACY OF COMPUTED TOMOGRAPHY-BASED, IMAGE-GUIDED NAVIGATION OF TEMPORAL BONE COMMENTS
    Abla, Adib
    Spetzler, Robert F.
    Day, J. D.
    Fayad, Jose N.
    Brackmann, Derald E.
    Origitano, T. C.
    Raza, Shaan
    Quinones-Hinojosa, Alfredo
    NEUROSURGERY, 2008, 63 (04) : 332 - 333
  • [42] Precision and accuracy of computed tomography foot measurements
    Smith, KE
    Commean, PK
    Robertson, DD
    Pilgram, T
    Mueller, MJ
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2001, 82 (07): : 925 - 929
  • [43] Multichannel Computed Tomography Versus Cone-Beam Computed Tomography: Linear Accuracy of In Vitro Measurements of the Maxilla for Implant Placement
    Fatemitabar, Seyed Ahmad
    Nikgoo, Arash
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (03) : 499 - 505
  • [44] Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography
    Suomalainen, A.
    Vehmas, T.
    Kortesniemi, M.
    Robinson, S.
    Peltola, J.
    DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (01) : 10 - 17
  • [45] Accuracy of linear measurements made on cone beam computed tomography scans at different magnifications
    Ghaznavi, Aisan
    Ghaznavi, Dara
    Valizadeh, Solmaz
    Vasegh, Zahra
    Al-Shuhayeb, Muna
    JOURNAL OF CONTEMPORARY MEDICAL SCIENCES, 2019, 5 (05): : 274 - 278
  • [46] Effect of section thickness on cone beam computed tomography-based measurements of intrabony defects compared with clinical measurements
    Nikolic-Jakoba, Natasa
    Barac, Milena
    Jankovic, Sasa
    Aleksic, Zoran
    Spin-Neto, Rubens
    Wenzel, Ann
    JOURNAL OF PERIODONTOLOGY, 2021, 92 (05) : 670 - 677
  • [47] Computed tomography-based surgical navigation for hip arthroplasty
    Ecker, Tiyno M.
    Tannast, Moritz
    Murphy, Stephen B.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (465) : 100 - 105
  • [48] Computed tomography-based angle measurements of the sagittal capitulum and trochlea position in relation to the humeral shaft
    Axel Przyklenk
    Michael Hackl
    Andra-Iza Iuga
    Tim Leschinger
    David Maintz
    Andreas Harbrecht
    Lars Peter Müller
    Kilian Wegmann
    Surgical and Radiologic Anatomy, 2023, 45 : 571 - 580
  • [49] Neuroanatomy of stroke: A computed tomography-based topographic analysis
    Subhadarsini, Sonali
    Shani, Aboobacker Sait
    Mishra, Dharma Niranjan
    JOURNAL OF THE ANATOMICAL SOCIETY OF INDIA, 2023, 72 (02) : 145 - 150
  • [50] Postoperative computed tomography-based control of syndesmotic screws
    Schwarz N.
    Köfer E.
    European Journal of Trauma, 2005, 31 (3): : 266 - 270