Advantages and challenges of high-dose thermoluminescent detectors

被引:16
|
作者
Kortov, V. [1 ]
Ustyantsev, Yu. [1 ]
机构
[1] Ural Fed Univ, Phys & Engn Inst, Ekaterinburg 620002, Russia
关键词
Thermoluminescent detectors; High-dose measurements; Deep traps; High-temperature TL peaks; Restoration of luminescent detector properties; MECHANISM; TRAPS;
D O I
10.1016/j.radmeas.2013.03.018
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The current status of high-dose luminescent detector investigations is discussed. The examples of successful applications of various materials for medium and high-dose luminescent detector creation are presented. High-dose irradiation effect on luminescence of TLD-500 (alpha-Al2O3:C) detectors has been described. The challenges of detector properties restoration after high-dose irradiation are considered. (c) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:299 / 302
页数:4
相关论文
共 50 条
  • [31] Optically stimulated luminescence of some thermoluminescent detectors as an indicator of absorbed radiation dose
    Jaek, I
    Kerikmäe, M
    Lust, A
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 459 - 462
  • [32] Optically stimulated luminescence of some thermoluminescent detectors as an indicator of absorbed radiation dose
    Jaek, I
    Kerikmäe, M
    Lust, A
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 459 - 462
  • [33] SKIN BETA-DOSE ASSESSMENT WITH ULTRA-THIN THERMOLUMINESCENT DETECTORS
    DAROSA, LAR
    CALDAS, LVE
    PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (06): : 677 - 682
  • [35] HIGH-DOSE BEHAVIOR OF CASO4 - DY THERMOLUMINESCENT PHOSPHORS AS DEDUCED BY A CONTINUOUS MODEL FOR TRAP DEPTHS
    OLIVERI, E
    FIORELLA, O
    MANGIA, M
    NUCLEAR INSTRUMENTS & METHODS, 1978, 154 (01): : 203 - 205
  • [36] Fading and residual responses for thermoluminescent dosimetry of silica beads irradiated using a high-dose electron-beam
    Ley, K.
    Hashim, S. A.
    Lohstroh, A.
    Shenton-Taylor, C.
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 182
  • [37] THERMOLUMINESCENT LIF DETECTORS - (SURVEY)
    KUDELIN, KM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1979, 22 (03) : 630 - 639
  • [38] THERMOLUMINESCENT LiF DETECTORS (SURVEY).
    Kudelin, K.M.
    Instruments and Experimental Techniques (English Translation of Pribory I Tekhnika Eksperimenta), 1979, 22 (3 pt 1): : 630 - 639
  • [39] High-dose pentazocine antagonizes the antinociception induced by high-dose morphine
    Shu, Haihua
    Wang, Zhao
    Ye, Fang
    Li, Qiaobo
    Dou, Yunling
    Lin, Yibin
    Huang, Wenqi
    Xiao, Xiaoshan
    LIFE SCIENCES, 2015, 130 : 1 - 6
  • [40] HIGH-DOSE DEXAMETHASONE AND HIGH-DOSE METOCLOPRAMIDE VERSUS HIGH-DOSE DEXAMETHASONE AND SULPIRIDE IN THE MANAGEMENT OF CISPLATIN-INDUCED EMESIS
    ROSENBLATT, E
    LEV, LM
    ROBINSON, E
    ONCOLOGY, 1988, 45 (04) : 297 - 299