Advantages and challenges of high-dose thermoluminescent detectors

被引:16
|
作者
Kortov, V. [1 ]
Ustyantsev, Yu. [1 ]
机构
[1] Ural Fed Univ, Phys & Engn Inst, Ekaterinburg 620002, Russia
关键词
Thermoluminescent detectors; High-dose measurements; Deep traps; High-temperature TL peaks; Restoration of luminescent detector properties; MECHANISM; TRAPS;
D O I
10.1016/j.radmeas.2013.03.018
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The current status of high-dose luminescent detector investigations is discussed. The examples of successful applications of various materials for medium and high-dose luminescent detector creation are presented. High-dose irradiation effect on luminescence of TLD-500 (alpha-Al2O3:C) detectors has been described. The challenges of detector properties restoration after high-dose irradiation are considered. (c) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:299 / 302
页数:4
相关论文
共 50 条
  • [11] High-efficiency thermoluminescent detectors for measuring the absorbed ionizing radiation dose in the environment
    N. L. Aluker
    J. M. Suzdaltseva
    M. Herrmann
    A. C. Dulepova
    Instruments and Experimental Techniques, 2016, 59 : 733 - 739
  • [12] The Challenges of High-Dose Chemotherapy in CNS Tumors
    Butturini, Anna
    Frappaz, Didier
    PEDIATRIC BLOOD & CANCER, 2010, 54 (04) : 652 - 653
  • [13] HIGH-DOSE CHARACTERISTICS OF CAF2 AND CASO4 THERMOLUMINESCENT DOSIMETERS
    BURGKHARDT, B
    SINGH, D
    PIESCH, E
    NUCLEAR INSTRUMENTS & METHODS, 1977, 141 (02): : 363 - 368
  • [14] Verification of heavy ion dose distributions using thermoluminescent detectors
    Geiss, OB
    Krämer, M
    Kraft, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 146 (1-4): : 541 - 544
  • [15] Extracting a Neutron Dose Using Only TLDs (Thermoluminescent Detectors)
    Dy, A.
    Shahnazi, K.
    Klein, S.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [16] Advantages of High-Dose Rate (HDR) Brachytherapy in Treatment of Prostate Cancer
    Molokov, A. A.
    Vanina, E. A.
    Tseluyko, S. S.
    PHYSICS OF CANCER: INTERDISCIPLINARY PROBLEMS AND CLINICAL APPLICATIONS (PC IPCA), 2017, 1882
  • [17] ADVANTAGES OF HIGH-DOSE RATE REMOTE AFTERLOADING SYSTEMS - PHYSICS OR BIOLOGY
    SPEISER, B
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (05): : 1133 - 1135
  • [18] Portable Wireless Digital Detectors: Advantages and Challenges
    Mahesh, Mahadevappa
    Berlenstein, Bruce
    Lewin, Jonathan
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2014, 11 (02) : 212 - 214
  • [19] DOSIMETRY OF SINGLE FRACTION HIGH-DOSE TOTAL-BODY IRRADIATION AS MEASURED BY THERMOLUMINESCENT DOSIMETERS
    LIU, JC
    BACZA, ET
    FINDLEY, DO
    FORELL, BW
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (09): : 1407 - 1408
  • [20] GLOW CURVE BEHAVIOR OF CASO4 - DY THERMOLUMINESCENT PHOSPHOR IN HIGH-DOSE REGION
    SRIVASTAVA, JK
    SUPE, SJ
    NUCLEAR INSTRUMENTS & METHODS, 1979, 160 (03): : 529 - 532