Fire resistance design of the bolted-welded hybrid composite connection in steel frame

被引:2
|
作者
Fan, Shenggang [1 ]
Liang, Dun [1 ]
Zeng, Shaoru [2 ]
Xu, Qingfeng [3 ]
Duan, Shengjie [1 ]
Wu, Yiwen [1 ]
机构
[1] Southeast Univ, Sch Civil Engn, Key Lab Concrete & Prestressed Concrete Struct, Minist Educ, Jiulonghu Campus, Nanjing 211189, Peoples R China
[2] Fujian Prov Inst Architectural Design & Res Co Ltd, Fuzhou 350001, Peoples R China
[3] Shanghai Key Lab Engn Struct Safety, SRIBS, Shanghai 200032, Peoples R China
基金
中国国家自然科学基金;
关键词
Bolted-welded hybrid composite connection; Fire resistance design; Flexural capacity; Initial rotation stiffness; PERFORMANCE; BEAM; JOINTS;
D O I
10.1016/j.firesaf.2022.103672
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
ABS T R A C T As a key component of the steel frame, the connection is important for the behaviour of the steel frame and for the prevention of progressive collapse under fire. To investigate the fire resistance of the bolted-welded hybrid composite connection in steel frame (BWC-SF), based on a completed test, a refined finite element model of the BWC-SF with a reinforced concrete slab was established. A parametric analysis was carried out to investigate the effects of the beam end load ratio, axial compression ratio of the column, thickness of the beam web and flange, thickness of the column web and flange, thickness of the concrete slab and reinforcing bar diameter. The fire resistance of the connection improved with a decrease in the beam end load ratio and reinforcing bar diameter and with an increase in the thicknesses of the beam flange, beam web and concrete slab. The flexural capacity and stiffness of BWC-SF components, which had great effects on the fire resistance, were analysed. The flexural capacity and initial rotation stiffness calculation method of the BWC-SF at elevated temperatures were estab-lished based on the component method and verified according to the test and finite element results.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Fire Resistance and Design of Composite Box Girder with Corrugated Steel Webs and Steel Bottom Plate
    Cheng, Haigen
    Shen, Qiang
    Zheng, Shangmin
    Guan, Chong
    Journal of Railway Engineering Society, 2024, 41 (09) : 30 - 35
  • [42] Experimental Research and FE Model of a Bolted Steel-CLT Composite Connection
    Milic, Milos
    Vacev, Todor
    Petronijevic, Predrag
    Nesovic, Ivan
    Zoric, Andrija
    Paunovic, Stepa
    Nikolic, Biljana Matejevic
    PERIODICA POLYTECHNICA-CIVIL ENGINEERING, 2024, 68 (01): : 8 - 22
  • [43] FATIGUE DESIGN OF HYBRID WELDED STEEL BEAMS
    Van Wittenberghe, Jeroen
    Van den Abeele, Filip
    PROCEEDINGS OF THE ASME 39TH INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, OMAE2020, VOL 3, 2020,
  • [44] Experimental Research on Seismic Mechanism of Innovative PEC Column-Steel Beam Composite Frame with T-stub Bolted Connection
    Fang Y.
    Xu X.
    Sun G.
    Fu X.
    Yingyong Jichu yu Gongcheng Kexue Xuebao/Journal of Basic Science and Engineering, 2019, 27 (05): : 1077 - 1090
  • [45] Design of steel portal frame buildings for fire safety
    Moss, P. J.
    Dhakal, R. P.
    Bong, M. W.
    Buchanan, A. H.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (05) : 1216 - 1224
  • [46] Steel Beam-To-Column Connection Fire Design
    Chloe, Jeanneret
    Austin, Martins-Robalino
    John, Gales
    Aikaterini, Genikomsou
    Panagiotis, Kotsovinos
    PROCEEDINGS OF THE CANADIAN SOCIETY OF CIVIL ENGINEERING ANNUAL CONFERENCE 2022, VOL 2, CSCE 2022, 2023, 348 : 121 - 135
  • [47] Calculation Method of Butt-Welded Connection of Steel Structure Post Fire
    Chen, Jianfeng
    MANUFACTURING PROCESS TECHNOLOGY, PTS 1-5, 2011, 189-193 : 3629 - 3632
  • [48] Experimental study on behavior of frame composite steel beams in fire
    Dong, Yu-Li
    Wang, De-Jun
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2008, 40 (02): : 178 - 182
  • [49] Behavior of external welded flange-bolted web joints of steel structure exposed to fire
    胡军
    姚斌
    厉培德
    Journal of Harbin Institute of Technology(New series), 2011, (01) : 89 - 95
  • [50] Design method for the fire resistance of glulam bolted connections under standard fire exposure
    Luo, Jing
    He, Minjuan
    Li, Zheng
    Zheng, Xiuzhi
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2024, 54 (06): : 1472 - 1480