Fire resistance design of the bolted-welded hybrid composite connection in steel frame

被引:2
|
作者
Fan, Shenggang [1 ]
Liang, Dun [1 ]
Zeng, Shaoru [2 ]
Xu, Qingfeng [3 ]
Duan, Shengjie [1 ]
Wu, Yiwen [1 ]
机构
[1] Southeast Univ, Sch Civil Engn, Key Lab Concrete & Prestressed Concrete Struct, Minist Educ, Jiulonghu Campus, Nanjing 211189, Peoples R China
[2] Fujian Prov Inst Architectural Design & Res Co Ltd, Fuzhou 350001, Peoples R China
[3] Shanghai Key Lab Engn Struct Safety, SRIBS, Shanghai 200032, Peoples R China
基金
中国国家自然科学基金;
关键词
Bolted-welded hybrid composite connection; Fire resistance design; Flexural capacity; Initial rotation stiffness; PERFORMANCE; BEAM; JOINTS;
D O I
10.1016/j.firesaf.2022.103672
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
ABS T R A C T As a key component of the steel frame, the connection is important for the behaviour of the steel frame and for the prevention of progressive collapse under fire. To investigate the fire resistance of the bolted-welded hybrid composite connection in steel frame (BWC-SF), based on a completed test, a refined finite element model of the BWC-SF with a reinforced concrete slab was established. A parametric analysis was carried out to investigate the effects of the beam end load ratio, axial compression ratio of the column, thickness of the beam web and flange, thickness of the column web and flange, thickness of the concrete slab and reinforcing bar diameter. The fire resistance of the connection improved with a decrease in the beam end load ratio and reinforcing bar diameter and with an increase in the thicknesses of the beam flange, beam web and concrete slab. The flexural capacity and stiffness of BWC-SF components, which had great effects on the fire resistance, were analysed. The flexural capacity and initial rotation stiffness calculation method of the BWC-SF at elevated temperatures were estab-lished based on the component method and verified according to the test and finite element results.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Fire resistance of strain hardening cementitious composite with hybrid PVA and steel fibers
    Liu, Jin-Cheng
    Tan, Kang Hai
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 135 : 600 - 611
  • [32] Behaviour model for post-tensioned bolted RC frame - steel brace connection
    Dogariu, A.
    Bordea, S.
    Dubina, D.
    COST ACTION C26: URBAN HABITAT CONSTRUCTIONS UNDER CATASTROPHIC EVENTS, 2010, : 829 - 834
  • [33] WELDED-STEEL VERSUS BOLTED-STEEL I-DIAPHRAGMS IN COMPOSITE BRIDGES
    KENNEDY, JB
    GRACE, NF
    SOLIMAN, M
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1989, 115 (02): : 417 - 432
  • [34] WELDED-STEEL VERSUS BOLTED-STEEL I-DIAPHRAGMS IN COMPOSITE BRIDGES
    BOYCE, WH
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1991, 117 (06): : 1878 - 1880
  • [35] Probability and sensitivity analysis of fire resistance of a steel frame
    Králik, J
    Varga, T
    INTERNATIONAL CONFERENCE ON COMPUTING, COMMUNICATIONS AND CONTROL TECHNOLOGIES, VOL 5, PROCEEDINGS, 2004, : 65 - 68
  • [36] Fire Resistance of the Rafter Used in the Steel Portal Frame
    Chybinski, Marcin
    Polus, Lukasz
    Kloj, Maciej
    3RD WORLD MULTIDISCIPLINARY CIVIL ENGINEERING, ARCHITECTURE, URBAN PLANNING SYMPOSIUM (WMCAUS 2018), 2019, 471
  • [37] Effect of connection flexibility on fire resistance of steel beams
    Liu, TCH
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1998, 45 (01) : 99 - 118
  • [38] Fire Resistance of Wood-Steel-Wood Bolted Timber Connections
    Peng, L.
    Hadjisophocleous, G.
    Mehaffey, J.
    Mohammad, M.
    STRUCTURES IN FIRE: PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE, 2010, : 552 - +
  • [39] SEISMIC RESISTANCE OF STEEL AND COMPOSITE FRAME STRUCTURES
    PLUMIER, A
    SCHLEICH, JB
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1993, 27 (1-3) : 159 - 176
  • [40] Anchored blind bolted composite connection to a concrete filled steel tubular column
    Agheshlui, Hossein
    Goldsworthy, Helen
    Gad, Emad
    Mirza, Olivia
    STEEL AND COMPOSITE STRUCTURES, 2017, 23 (01): : 115 - 130