Fire resistance design of the bolted-welded hybrid composite connection in steel frame

被引:2
|
作者
Fan, Shenggang [1 ]
Liang, Dun [1 ]
Zeng, Shaoru [2 ]
Xu, Qingfeng [3 ]
Duan, Shengjie [1 ]
Wu, Yiwen [1 ]
机构
[1] Southeast Univ, Sch Civil Engn, Key Lab Concrete & Prestressed Concrete Struct, Minist Educ, Jiulonghu Campus, Nanjing 211189, Peoples R China
[2] Fujian Prov Inst Architectural Design & Res Co Ltd, Fuzhou 350001, Peoples R China
[3] Shanghai Key Lab Engn Struct Safety, SRIBS, Shanghai 200032, Peoples R China
基金
中国国家自然科学基金;
关键词
Bolted-welded hybrid composite connection; Fire resistance design; Flexural capacity; Initial rotation stiffness; PERFORMANCE; BEAM; JOINTS;
D O I
10.1016/j.firesaf.2022.103672
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
ABS T R A C T As a key component of the steel frame, the connection is important for the behaviour of the steel frame and for the prevention of progressive collapse under fire. To investigate the fire resistance of the bolted-welded hybrid composite connection in steel frame (BWC-SF), based on a completed test, a refined finite element model of the BWC-SF with a reinforced concrete slab was established. A parametric analysis was carried out to investigate the effects of the beam end load ratio, axial compression ratio of the column, thickness of the beam web and flange, thickness of the column web and flange, thickness of the concrete slab and reinforcing bar diameter. The fire resistance of the connection improved with a decrease in the beam end load ratio and reinforcing bar diameter and with an increase in the thicknesses of the beam flange, beam web and concrete slab. The flexural capacity and stiffness of BWC-SF components, which had great effects on the fire resistance, were analysed. The flexural capacity and initial rotation stiffness calculation method of the BWC-SF at elevated temperatures were estab-lished based on the component method and verified according to the test and finite element results.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Experimental study and numerical simulation analysis of the Bolted-Welded hybrid connection joint of steel frame under fire
    Fan, Shenggang
    Duan, Shengjie
    Zeng, Shaoru
    Wu, Yiwen
    Ding, Runmin
    STRUCTURES, 2022, 41 : 77 - 98
  • [2] Experimental Investigation on Flange Bolted-Welded Connection for Steel Frame
    Jiao, Y. F.
    Liu, X. M.
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON ELECTRICAL, AUTOMATION AND MECHANICAL ENGINEERING (EAME 2015), 2015, 13 : 275 - 278
  • [3] Experimental study on flange bolted-welded connection for steel column-beam
    He, Minjuan
    Jiao, Yufeng
    Ma, Renle
    Tongji Daxue Xuebao/Journal of Tongji University, 2013, 41 (12): : 1787 - 1792
  • [4] Progressive Collapse Mechanism Analysis of Concrete-Filled Square Steel Tubular Column to Steel Beam Joint with Bolted-Welded Hybrid Connection
    Wang, Jing-Xuan
    Yang, Yong
    Xian, Wei
    Li, Qiu-Ying
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2020, 20 (05) : 1618 - 1635
  • [5] Standard Pushout Tests and Design Rules for a Bolted-Welded Hybrid Demountable Shear Connector
    He, Jun
    Suwaed, Ahmed S. H.
    Vasdravellis, George
    Wang, Sihao
    JOURNAL OF STRUCTURAL ENGINEERING, 2022, 148 (08)
  • [6] Experimental Research on Friction Plane of Composite Coating of Long-Span Bolted-Welded Steel Girder Joints
    Jia, Wei-Zhong
    Duan, Kuang-Shi
    Fan, Xian-Zheng
    Bridge Construction, 2022, 52 (04) : 68 - 73
  • [7] Mechanical Performance of Welded-Bolted Hybrid Connection Joints Between Fire-Resistant Steel Columns and Beams Under Fire
    Wang, Yuedong
    Liu, Jie
    Zhang, Zeyu
    Jiang, Luzhen
    Zeng, Lijing
    Qing, Ma
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2024, 22 (07) : 1159 - 1177
  • [8] Static and seismic experiment for bolted-welded joint in modularized prefabricated steel structure
    Liu, X. C.
    Pu, S. H.
    Zhang, A. L.
    Xu, A. X.
    Ni, Z.
    Sun, Y.
    Ma, L.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 115 : 417 - 433
  • [9] Fire resistance and flexural load capacity of beam-column welded-bolted hybrid connection joints under post-earthquake fire
    Xu, Jixiang
    Chong, Xinda
    Han, Jianping
    STRUCTURES, 2024, 62
  • [10] Structural fuse design of bolted steel frame with low yield point angle steel connection components
    Wang, Meng
    Tong, Yunshan
    Sun, Yi
    Yang, Lu
    THIN-WALLED STRUCTURES, 2022, 179