Imprinted-Zeolite-X-Based Sensor for Non-Enzymatic Detection of Blood Glucose by Potentiometry

被引:1
|
作者
Khasanah, Miratul [1 ]
Widati, Alfa Akustia [1 ,2 ]
Handajani, Usreg Sri [1 ]
Mastura, Akhsin [1 ]
Sari, Eka Yunicha [1 ]
机构
[1] Univ Airlangga, Fac Sci & Technol, Chem Dept, Surabaya 60115, Indonesia
[2] Univ Airlangga, Supramodificat & Nanomicro Engn Res Grp, Surabaya 60115, Indonesia
关键词
imprinted zeolite X; potentiometric sensor; blood glucose; medical; ION-SELECTIVE ELECTRODES; CARBON-PASTE ELECTRODE; BIOSENSORS; NANOPARTICLES;
D O I
10.3390/chemengineering6050071
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The development of sensors based on imprinted zeolite X to detect blood glucose through potentiometry was performed. In this study, the sensor was made of a mixture of carbon paste and imprinted zeolite X. Zeolite X was synthesized using a sol-gel-hydrothermal method at a temperature of 100 degrees C with basic materials of NaAlO2, NaOH, TEOS, and distilled water. The characterization results of XRD showed the presence of specific peaks, which were confirmed with standard zeolite X. Imprinted zeolite X exhibited a 20 times greater adsorption capacity size, and an adsorption efficiency 3 times greater than that of zeolite X. This is thought to be due to the presence of a molecular template within it. The IZ-carbon paste electrode showed optimum performance due to a mass ratio of carbon, paraffin, and imprinted zeolite X of 12:7:1. The electrode performance was expressed by the Nernst factor value of 30 mV/decade, the measuring range of 10(-4)-10(-2) M, the upper detection limit of 1.38 x 10(-2) M, and the lower detection limit of 1.28 x 10(-4) M, so this electrode can be used for glucose analysis with a normal concentration (70-110 mg/dL or equivalent to 3.8 x 10(-3)-6.1 x 10(-3) M), as well as the glucose concentration of people with diabetes mellitus (>200 mg/dL or about 10(-2) M). This electrode showed precision values of 97.14-99.02%, accuracy values of 98.65-99.39%, and electrode response times of 10-13 s. The electrodes showed high stability for more than 5 weeks with 141 uses. The electrodes also showed high selectivity for glucose in the matrix of uric acid, urea, NaCl, and KCl. Therefore, its use as an alternative electrode for routine glucose analysis in the medical field is recommended.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Imprinted Zeolite Modified Carbon Paste Electrode as a Selective Sensor for Blood Glucose Analysis by Potentiometry
    Khasanah, Miratul
    Widati, Alfa Akustia
    Handajani, Usreg Sri
    Harsini, Muji
    Ilmiah, Bahrotul
    Oktavia, Irene Dinda
    [J]. INDONESIAN JOURNAL OF CHEMISTRY, 2020, 20 (06) : 1301 - 1310
  • [2] Non-enzymatic glucose sensor based on molecularly imprinted polymer: a theoretical, strategy fabrication and application
    Haiyan Wu
    Qiong Tian
    Wei Zheng
    Yan Jiang
    Jicheng Xu
    Xin Li
    Wenchi Zhang
    Fengxian Qiu
    [J]. Journal of Solid State Electrochemistry, 2019, 23 : 1379 - 1388
  • [3] Non-enzymatic glucose sensor based on molecularly imprinted polymer: a theoretical, strategy fabrication and application
    Wu, Haiyan
    Tian, Qiong
    Zheng, Wei
    Jiang, Yan
    Xu, Jicheng
    Li, Xin
    Zhang, Wenchi
    Qiu, Fengxian
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2019, 23 (05) : 1379 - 1388
  • [4] Carbon nanoparticles based non-enzymatic glucose sensor
    Pulidindi, Indra Neel
    Gedanken, Aharon
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2014, 94 (01) : 28 - 35
  • [5] Non-enzymatic Glucose Sensor Based on Nickel/Carbon Composite
    Marini, Silvia
    Ben Mansour, Nabil
    Hjiri, Mokhtar
    Dhahri, Ramzi
    El Mir, Lassaad
    Espro, Claudia
    Bonavita, Anna
    Galvagno, Signorino
    Neri, Giovanni
    Leonardi, Salvatore Gianluca
    [J]. ELECTROANALYSIS, 2018, 30 (04) : 727 - 733
  • [6] NON-ENZYMATIC ELECTROCHEMICAL GLUCOSE DETECTION
    TINDALL, CE
    MCMULLEN, JK
    MORROW, DJ
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 1985, 154 (07) : 288 - 288
  • [7] A novel sensitive non-enzymatic glucose sensor
    Xin Huang Kang
    [J]. Chinese Chemical Letters, 2007, (02) : 189 - 191
  • [8] Pd nanocube as non-enzymatic glucose sensor
    Ye, Jyun-Sian
    Chen, Chin-Wei
    Lee, Chien-Liang
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 : 569 - 574
  • [9] A novel sensitive non-enzymatic glucose sensor
    Kang, Xin Huang
    Mai, Zhi Bin
    Zou, Xiao Yong
    Cai, Pei Xiang
    Mo, Jin Yuan
    [J]. CHINESE CHEMICAL LETTERS, 2007, 18 (02) : 189 - 191
  • [10] A potentiometric non-enzymatic glucose sensor using a molecularly imprinted layer bonded on a conducting polymer
    Kim, Dong-Min
    Moon, Jong-Min
    Lee, Won-Chul
    Yoon, Jang-Hee
    Choi, Cheol Soo
    Shim, Yoon-Bo
    [J]. BIOSENSORS & BIOELECTRONICS, 2017, 91 : 276 - 283