A potentiometric non-enzymatic glucose sensor using a molecularly imprinted layer bonded on a conducting polymer

被引:109
|
作者
Kim, Dong-Min [1 ]
Moon, Jong-Min [1 ]
Lee, Won-Chul [1 ]
Yoon, Jang-Hee [2 ]
Choi, Cheol Soo [3 ]
Shim, Yoon-Bo [1 ]
机构
[1] Pusan Natl Univ, Inst Bio Physio Sensor Technol IBST, Dept Chem, Busan 46241, South Korea
[2] Korea Basic Sci Inst, Busan Ctr, Busan 46742, South Korea
[3] Gachon Univ, Grad Sch Med, Dept Internal Med, Gil Med Ctr, Incheon, South Korea
来源
基金
新加坡国家研究基金会;
关键词
Conducting polymer; Molecularly imprinted polymer; Aminophenyl boronic acid; Glucose; Potentiometric sensor; RECOGNITION; BIOSENSORS; CARBON;
D O I
10.1016/j.bios.2016.12.046
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A non-enzymatic potentiometric glucose sensor for the determination of glucose in the micomolar level in saliva was developed based on a molecularly imprinted polymer (MIP) binding on a conducting polymer layer. A MIP containing acrylamide, and aminophenyl boronic acid, as a host molecule to glucose, was immobilized on benzoic acid-functionalized poly(terthiophene) (pTBA) by the amide bond formation onto a gold nanoparticles deposited-screen printed carbon electrode (pTBA/AuNPs/SPCE). Aromatic boronic acid was incorporated into the MIP layer to stably capture glucose and create a potentiometric signal through the changed pKa value of polymer film by the formation of boronate anion-glucose complex with generation of H+ ions by the cis-diol reaction. Reversible binding and extraction of glucose on the sensor surface was observed using a quartz crystal microbalance. Each layer of the sensor probe was characterized by cyclic voltammetry, electrochemical impedance spectroscopy, X-ray photoelectron spectroscopy, and atomic force microscopy. The potentiometric response at the optimized conditions exhibited a wide linear dynamic range of 3.2 x 10(-7) to 1.0x10(-3) M, with a detection limit of 1.9 (+/- 0.15)x 10(-7) M. The sensor probe revealed an excellent selectivity and sensitivity for glucose compared to other saccharides. In addition, the reliability of the proposed glucose sensor was evaluated in physiological fluid samples of saliva and finger prick blood.
引用
收藏
页码:276 / 283
页数:8
相关论文
共 50 条
  • [1] Non-enzymatic glucose sensor based on molecularly imprinted polymer: a theoretical, strategy fabrication and application
    Haiyan Wu
    Qiong Tian
    Wei Zheng
    Yan Jiang
    Jicheng Xu
    Xin Li
    Wenchi Zhang
    Fengxian Qiu
    [J]. Journal of Solid State Electrochemistry, 2019, 23 : 1379 - 1388
  • [2] Non-enzymatic glucose sensor based on molecularly imprinted polymer: a theoretical, strategy fabrication and application
    Wu, Haiyan
    Tian, Qiong
    Zheng, Wei
    Jiang, Yan
    Xu, Jicheng
    Li, Xin
    Zhang, Wenchi
    Qiu, Fengxian
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2019, 23 (05) : 1379 - 1388
  • [3] Numerical Modeling on Non-enzymatic, Potentiometric Glucose Sensor
    Kanagasabapathy, M.
    Bapu, G. N. K. Ramesh
    Linga, Praveen
    Gnanamuthu, R. M.
    [J]. PORTUGALIAE ELECTROCHIMICA ACTA, 2012, 30 (04) : 295 - 306
  • [4] Potentiometric sensor for determination of neutral bisphenol A using a molecularly imprinted polymer as a receptor
    Kou, Li-Juan
    Liang, Rong-Ning
    Wang, Xue-Wei
    Chen, Yan
    Qin, Wei
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (14) : 4931 - 4936
  • [5] Potentiometric sensor for determination of neutral bisphenol A using a molecularly imprinted polymer as a receptor
    Li-Juan Kou
    Rong-Ning Liang
    Xue-Wei Wang
    Yan Chen
    Wei Qin
    [J]. Analytical and Bioanalytical Chemistry, 2013, 405 : 4931 - 4936
  • [6] Non-enzymatic lactose molecularly imprinted sensor based on disposable graphite paper electrode
    da Silva, Jose Luiz
    Buffon, Edervaldo
    Beluomini, Maisa Azevedo
    Pradela-Filho, Lauro Antonio
    Gouveia Araujo, Diele Aparecida
    Santos, Andre Luiz
    Takeuchi, Rgina Massako
    Stradiotto, Nelson Ramos
    [J]. ANALYTICA CHIMICA ACTA, 2021, 1143 : 53 - 64
  • [7] Molecularly imprinted polymer (biomimetic) based potentiometric sensor for atrazine
    Prasad, K.
    Prathish, K. P.
    Gladis, J. Mary
    Naidu, G. R. K.
    Rao, T. Prasada
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (01) : 65 - 70
  • [8] A molecular dynamics study on glucose molecular recognition by a non-enzymatic selective sensor based on a conducting polymer
    Zanuy, David
    Fabregat, Georgina
    Ferreira, Carlos A.
    Aleman, Carlos
    [J]. PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2019, 21 (15) : 8099 - 8107
  • [9] Construction of a selective non-enzymatic electrochemical sensor based on hollow nickel nanospheres/carbon dots-chitosan and molecularly imprinted polymer film for the detection of glucose
    Wu, Haiyan
    Zheng, Wei
    Jiang, Yan
    Xu, Jicheng
    Qiu, Fengxian
    [J]. NEW JOURNAL OF CHEMISTRY, 2021, 45 (46) : 21676 - 21683
  • [10] Functional gold nanorod particles on conducting polymer poly(3-octylthiophene) as non-enzymatic glucose sensor