Lowering the limit of detection in high spatial resolution electron beam microanalysis with the microcalorimeter energy dispersive X-ray spectrometer

被引:19
|
作者
Newbury, D
Wollman, D
Irwin, K
Hilton, G
Martinis, J
机构
[1] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
[2] Natl Inst Stand & Technol, Boulder, CO 80303 USA
关键词
electron probe X-ray microanalysis; energy dispersive X-ray spectrometry; microanalysis; microcalorimetry; scanning electron microscopy; X-ray microanalysis; X-ray spectrometry;
D O I
10.1016/S0304-3991(99)00028-5
中图分类号
TH742 [显微镜];
学科分类号
摘要
Low-beam-energy X-ray microanalysis with the field-emission-gun scanning electron microscope suffers limitations due to physical factors of X-ray generation. Instrumental limitations are imposed by the poor resolution of the conventional semiconductor energy dispersive X-ray spectrometry. Wavelength dispersive X-ray spectrometry provides sufficient resolution to solve spectroscopic problems, but the poor geometric efficiency and the single channel nature of spectrum measurement restrict its practical use for low-beam-energy microanalysis. The microcalorimeter energy dispersive X-ray spectrometer combines high resolution ( < 10 eV) with energy dispersive operation. The utility of this new spectrometer is examined in four categories: (1) qualitative analysis; (2) quantitative analysis; (3) chemical speciation studies, and (4) measurement of trace constituents. For the low-beam-energy regime, the microcalorimeter energy dispersive X-ray spectrometer provides important new performance capabilities for qualitative analysis and chemical speciation studies. However, there are limitations for quantitative studies imposed by detector geometrical characteristics. In addition, trace element detection is impractical below 0.001 mass fraction with low-beam energy ( < 5 keV) because of count rate limitations. Published by Elsevier Science B.V.
引用
收藏
页码:73 / 88
页数:16
相关论文
共 50 条
  • [1] High-resolution, energy-dispersive microcalorimeter spectrometer for X-ray microanalysis
    Wollman, DA
    Irwin, KD
    Hilton, GC
    Dulcie, LL
    Newbury, DE
    Martinis, JM
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1997, 188 : 196 - 223
  • [2] High-resolution microcalorimeter energy-dispersive spectrometer for x-ray microanalysis and particle analysis
    Wollman, DA
    Hilton, GC
    Irwin, KD
    Dulcie, LL
    Bergren, NF
    Newbury, DE
    Woo, KS
    Liu, BYH
    Diebold, AC
    Martinis, JM
    [J]. CHARACTERIZATION AND METROLOGY FOR ULSI TECHNOLOGY, 1998, 449 : 799 - 804
  • [3] The Approaching Revolution in X-Ray Microanalysis: The Microcalorimeter Energy Dispersive Spectrometer
    D. E. Newbury
    D. A. Wollman
    G. C. Hilton
    K. D. Irwin
    N. F. Bergren
    D. A. Rudman
    J. M. Martinis
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2000, 244 : 627 - 635
  • [4] The approaching revolution in X-ray microanalysis: The microcalorimeter energy dispersive spectrometer
    Newbury, DE
    Wollman, DA
    Hilton, GC
    Irwin, KD
    Bergren, NF
    Rudman, DA
    Martinis, JM
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2000, 244 (03) : 627 - 635
  • [5] X-ray microanalysis of biological samples by high-resolution energy dispersive microcalorimeter spectrometer using a low-voltage scanning electron microscope
    Nakai, Izumi
    Baba, Yukari
    Tanaka, Keiichi
    Nakayama, Satoshi
    Hanashima, Minako
    Hokura, Akiko
    Homma, Yoshikazu
    [J]. CHEMISTRY LETTERS, 2008, 37 (03) : 304 - 305
  • [6] High-Spatial-Resolution Low-Energy Electron Beam X-Ray Microanalysis
    Ian Barkshire
    Peter Karduck
    Werner P. Rehbach
    Silvia Richter
    [J]. Microchimica Acta, 2000, 132 : 113 - 128
  • [7] High-spatial-resolution low-energy electron beam X-ray microanalysis
    Barkshire, I
    Karduck, P
    Rehbach, WP
    Richter, S
    [J]. MIKROCHIMICA ACTA, 2000, 132 (2-4) : 113 - 128
  • [8] Microcalorimeter-type energy dispersive X-ray spectrometer for a transmission electron microscope
    Hara, Toru
    Tanaka, Keiichi
    Maehata, Keisuke
    Mitsuda, Kazuhisa
    Yamasaki, Noriko Y.
    Ohsaki, Mitsuaki
    Watanabe, Katsuaki
    Yu, Xiuzhen
    Ito, Takuji
    Yamanaka, Yoshihiro
    [J]. JOURNAL OF ELECTRON MICROSCOPY, 2010, 59 (01): : 17 - 26
  • [9] Microcalorimeter-type energy dispersive X-ray spectrometer for a transmission electron microscope
    Advanced Nano-Characterization Center, National Institute for Materials Science, 1-1 Namiki, Ibaraki, Tsukuba
    305-0044, Japan
    不详
    410-1393, Japan
    不详
    819-0395, Japan
    不详
    229-8510, Japan
    不详
    196-8558, Japan
    不详
    300-2611, Japan
    [J]. Microsc., 1 (17-26):
  • [10] Energy dispersive X-ray microanalysis in transmission electron microscopy
    Armigliato, A
    [J]. EDXRS-98: PROCEEDINGS OF THE EUROPEAN CONFERENCE ON ENERGY DISPERSIVE X-RAY SPECTROMETRY 1998, 1999, : 173 - 177