Comparison of the accuracy of immediate implant placement using static and dynamic computer-assisted implant system in the esthetic zone of the maxilla: a prospective study

被引:21
|
作者
Feng, Yuzhang [1 ,2 ,3 ]
Su, Zhenya [1 ,2 ,3 ]
Mo, Anchun [1 ,2 ,3 ]
Yang, Xingmei [1 ,2 ,3 ]
机构
[1] Sichuan Univ, State Key Lab Oral Dis, 14 Sect 3,Renmin Nan Rd, Chengdu, Sichuan, Peoples R China
[2] Sichuan Univ, Natl Clin Res Ctr Oral Dis, 14Sect 3,Renmin Nan Rd, Chengdu, Sichuan, Peoples R China
[3] Sichuan Univ, West China Hosp Stomatol, Dept Oral Implantol, 14 Sect 3,Renmin Nan Rd, Chengdu, Sichuan, Peoples R China
关键词
Accuracy; Computer-assisted surgery; Dental implant; Immediate implant placement; Dynamic navigation; Static template; TECHNOLOGY APPLICATIONS; SURGICAL GUIDES; SURGERY; DENTISTRY; EXTRACTION; TOLERANCE; ERRORS;
D O I
10.1186/s40729-022-00464-w
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study aimed to compare the accuracy of fully guided between dynamic and static computer-assisted implant surgery (CAIS) systems for immediate implant placement in the esthetic zone. Methods: A total of 40 qualified patients requiring immediate implant placement in the esthetic zone were randomly and equally assigned to either static CAIS group (n = 20) or dynamic CAIS groups (n = 20). Global deviations at entry, apex, and angular deviation between placed and planned implant position were measured and compared as primary outcomes. Secondary outcomes were the deviation of implant placement at mesial-distal, labial-palatal, and coronal-apical directions. Results: For the immediate implant placement, the mean global entry deviations in static and dynamic CAIS groups were 0.99 +/- 0.63 mm and 1.06 +/- 0.55 mm (p = 0.659), while the mean global apex deviations were 1.50 +/- 0.75 mm and 1.18 +/- 0.53 mm (p = 0.231), respectively. The angular deviation in the static and dynamic CAIS group was 3.07 +/- 2.18 degrees and 3.23 +/- 1.67 degrees (p = 0.547). No significant differences were observed for the accuracy parameters of immediate implant placement between static and dynamic CAIS systems, except the deviation of the implant at entry in the labial-palatal direction in the dynamic CAIS group was significantly more labial than of the static CAIS (p = 0.005). Conclusions: This study demonstrated that clinically acceptable accuracy of immediate implant placement could be achieved using static and dynamic CAIS systems.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Accuracy assessment of computer-assisted flapless implant placement in partial edentulism
    Van Assche, N.
    van Steenberghe, D.
    Quirynen, M.
    Jacobs, R.
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2010, 37 (04) : 398 - 403
  • [32] Influence of implant macrodesign and insertion connection technology on the accuracy of static computer-assisted implant surgery
    El Kholy, Karim
    Ebenezer, Supriya
    Wittneben, Julia-Gabriela
    Lazarin, Rafael
    Rousson, Dominique
    Buser, Daniel
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (05) : 1073 - 1079
  • [33] The Impact of Surgical Guide Fixation and Implant Location on Accuracy of Static Computer-Assisted Implant Surgery
    Pessoa, Roberto
    Siqueira, Rafael
    Li, Junying
    Saleh, Islam
    Meneghetti, Priscila
    Bezerra, Fabio
    Wang, Hom-Lay
    Mendonca, Gustavo
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (02): : 155 - 164
  • [34] Influence of template design on the accuracy of static computer-assisted implant surgery
    Chung, Jinmook
    Park, Junghyun
    Son, Hyeonseong
    Hong, Seoung-Jin
    Pae, Ahran
    JOURNAL OF ADVANCED PROSTHODONTICS, 2025, 17 (01): : 22 - 35
  • [35] Clinical and Radiologic Evaluation of a Fully Tapered Implant with Immediate Placement in the Esthetic Zone: A Prospective Case Series Study
    Cardaropoli, Daniele
    Tamagnone, Lorenzo
    Roffredo, Alessandro
    De Maria, Andrea
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2022, 42 (05) : 631 - +
  • [36] The thickness of labial bone affects the esthetics of immediate implant placement and provisionalization in the esthetic zone: A prospective cohort study
    Yang, Xingmei
    Zhou, Tengfei
    Zhou, Nan
    Man, Yi
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (03) : 482 - 491
  • [37] Influence of surgical guide support and implant site location on accuracy of static Computer-Assisted Implant Surgery
    El Kholy, Karim
    Lazarin, Rafael
    Janner, Simone F. M.
    Faerber, Karin
    Buser, Ramona
    Buser, Daniel
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (11) : 1067 - 1075
  • [38] Impact of labially inclined implant axes on immediate implant placement and provisionalization in anterior maxilla: A prospective cohort study
    Ren, Shuxin
    Guo, Houzuo
    Yi, Chun
    Lin, Ye
    Di, Ping
    Jiang, Xi
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024,
  • [39] Esthetic Outcomes for Immediate Implant Placement with Immediate Provisionalization in the Anterior Maxilla with Buccal Dehiscence: Results of a Comparative Pilot Study
    Pohl, Sebastian
    Pohl, Veronika
    Pokorny, Georg Benedikt Mailath
    Haas, Robert
    Cede, Julia
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (03) : 508 - 514
  • [40] Accuracy of keyless vs drill-key implant systems for static computer-assisted implant surgery using two guide-hole designs compared to freehand implant placement: an in vitro study
    Raabe, Clemens
    Schuetz, Tabea S.
    Chappuis, Vivianne
    Yilmaz, Burak
    Abou-Ayash, Samir
    Couso-Queiruga, Emilio
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2023, 9 (01) : 4